MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT
Journal Article

Eectrical grid linked to PV/wind system based fuzzy controller and PID controller tuned by PSO for improving LVRT

2025
Request Book From Autostore and Choose the Collection Method
Overview
This paper presents the use of a static synchronous compensators (STATCOM) device to improve the low voltage ride through (LVRT) ability of an electrical network consisting of wind farms that produce 9 MW and 1 MW PV stations during grid faults. A hybrid energy model is connected with 100 MVAR STATCOM at the point of common coupling (PCC) through line to line fault occurs on the grid. STATCOM control is used to detect the voltage at the PCC bus through occurring line to line (LL) faults by compensating reactive energy. A method of particle swarm optimization (PSO) is utilized for adjusting the optimum value of proportional-integral-derivative (PID) STATCOM control. STATCOM is controlled by (PID) and is compared with STATCOM controlled by fuzzy logic control (FLC). The proposed system has been performed utilizing Matlab/Simulink. Results of the simulation clear effectiveness and the ability of STATCOM with FLC in improving LVRT, power quality, and mitigation voltage dip, during grid faults like line to line (LL) faults as compared with STATCOM with PID control.
Publisher
Nature Publishing Group UK

MBRLCatalogueRelatedBooks