MbrlCatalogueTitleDetail

Do you wish to reserve the book?
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用
Journal Article

CardioChekPA便携式全血分析仪检测血脂性能及其在社区脑卒中高危人群血脂筛查中的应用

2013
Request Book From Autostore and Choose the Collection Method
Overview
目的评价CardioChekPA便携式全血检测仪(便携式全血检测仪)检测血脂的可靠性,探讨其用于社区脑卒中高危人群血脂筛查的可行性及准确性。方法根据美国国家临床实验室标准化委员会制定的患者样本比对实验及偏差评价指南EP9-A文件标准,分别以ADVIA2400全自动生化分析仪和便携式全血检测仪为参考仪器(目标检测系统)和试验系统,检测受试者血清总胆固醇、甘油三酯、高密度脂蛋白胆固醇和低密度脂蛋白胆固醇水平,计算两种检测系统相关系数和直线回归方程,并对其预期偏差进行评估;在比对基础上应用便携式全血检测仪检测1263例社区年龄〉40岁的高危人群血脂水平。结果便携式全血检测仪检测血脂与ADVIA2400全自动生化分析仪具有良好的相关性(r〉0.975,P〈O.05),不同医学决定水平可允许误差均位于预期偏差的95%CI内,提示两种仪器检测总胆固醇、甘油三酯、高密度脂蛋白胆固醇、低密度脂蛋白胆固醇水平相近,数据可接受。社区筛查共检测1263例受试者,异常检出率为总胆周醇347例(27.47%)、甘油三酯348例(27.55%)、高密度脂蛋白胆固醇62例(4.91%)、低密度脂蛋白胆固醇441例(34.92%)。结论CardioChekPA便携式全血检测仪测定胆固醇、甘油三酯、高密度脂蛋白胆固醇和低密度脂蛋白胆同醇的结果与实验室常规ADVIA2400全自动生化分析仪测定结果相近,结果准确可信,可用于社区流行病学调查。