MbrlCatalogueTitleDetail

Do you wish to reserve the book?
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
Journal Article

高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响

2023
Request Book From Autostore and Choose the Collection Method
Overview
Abstract Background In recent years, technological advances in the field of diabetes have revolutionized the management, prognosis, and quality of life of diabetes patients and their environment. The aim of our study was to evaluate the impact of implementing the MiniMed 780G closed‐loop system in a pediatric and adolescent population previously treated with a continuous subcutaneous insulin infusion pump and intermittent glucose monitoring. Methods Data were collected from 28 patients with type 1 diabetes aged 6 to 17 years, with a follow‐up of 6 months. We included both glucometric and quality of life variables, as well as quality of life in primary caregivers. Metabolic control variables were assessed at baseline (before system change) and at different cutoff points after initiation of the closed‐loop system (48 hours, 7 days, 14 days, 21 days, 1 month, 3 months, 6 months). Results Time in range 70–180 mg/dL increased from 59.44% at baseline to 74.29% in the first 48 hours after automation of the new system, and this improvement was maintained at the other cutoff points, as was time in hyperglycemia 180–250 mg/dL (24.44% at baseline to 18.96% at 48 hours) and >250 mg/dL (11.71% at baseline to 3.82% at 48 hours). Conclusions Our study showed an improvement in time in range and in all time spent in hyperglycemia from the first 48 hours after the automation of the system, which was maintained at 6 months.