Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
by
Fernando Moreno‐Jabato
, Alfonso Lendínez‐Jurado
, Icía Becerra‐Paz
, Isabel Leiva‐Gea
, Ana Gómez‐Perea
, Leopoldo Tapia‐Ceballos
, María F. Martos‐Lirio
, Ana B. Ariza‐Jiménez
in
MiniMedTM 780G
/ 儿童1型糖尿病
/ 目标范围内时间
/ 高级混合闭环
/ 高血糖时间
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
by
Fernando Moreno‐Jabato
, Alfonso Lendínez‐Jurado
, Icía Becerra‐Paz
, Isabel Leiva‐Gea
, Ana Gómez‐Perea
, Leopoldo Tapia‐Ceballos
, María F. Martos‐Lirio
, Ana B. Ariza‐Jiménez
in
MiniMedTM 780G
/ 儿童1型糖尿病
/ 目标范围内时间
/ 高级混合闭环
/ 高血糖时间
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
高级混合闭环系统对儿童和青少年1型糖尿病患者血糖指标和生活质量的影响
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Abstract Background In recent years, technological advances in the field of diabetes have revolutionized the management, prognosis, and quality of life of diabetes patients and their environment. The aim of our study was to evaluate the impact of implementing the MiniMed 780G closed‐loop system in a pediatric and adolescent population previously treated with a continuous subcutaneous insulin infusion pump and intermittent glucose monitoring. Methods Data were collected from 28 patients with type 1 diabetes aged 6 to 17 years, with a follow‐up of 6 months. We included both glucometric and quality of life variables, as well as quality of life in primary caregivers. Metabolic control variables were assessed at baseline (before system change) and at different cutoff points after initiation of the closed‐loop system (48 hours, 7 days, 14 days, 21 days, 1 month, 3 months, 6 months). Results Time in range 70–180 mg/dL increased from 59.44% at baseline to 74.29% in the first 48 hours after automation of the new system, and this improvement was maintained at the other cutoff points, as was time in hyperglycemia 180–250 mg/dL (24.44% at baseline to 18.96% at 48 hours) and >250 mg/dL (11.71% at baseline to 3.82% at 48 hours). Conclusions Our study showed an improvement in time in range and in all time spent in hyperglycemia from the first 48 hours after the automation of the system, which was maintained at 6 months.
Publisher
Wiley
Subject
This website uses cookies to ensure you get the best experience on our website.