Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The validity of breath collection bags method in detecting using the novel : a multicenter clinical study in 257 subjects
by
Robert Hardi
, Nilesh Mehta
, Jeff O. Gonzalez
, Mahmudul Haq
, Keith Friedenberg
, Haim Shirin
, Gary Gottlieb
, Ravi Ganeshappa
, Jorge-Shmuel Delgado
, Allan Coates
, Vered Richter
, Blake A. Jones
, Steven F. Moss
, Sabine Hazan
, David Gatof
, Dov Abramowitz
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The validity of breath collection bags method in detecting using the novel : a multicenter clinical study in 257 subjects
by
Robert Hardi
, Nilesh Mehta
, Jeff O. Gonzalez
, Mahmudul Haq
, Keith Friedenberg
, Haim Shirin
, Gary Gottlieb
, Ravi Ganeshappa
, Jorge-Shmuel Delgado
, Allan Coates
, Vered Richter
, Blake A. Jones
, Steven F. Moss
, Sabine Hazan
, David Gatof
, Dov Abramowitz
in
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The validity of breath collection bags method in detecting using the novel : a multicenter clinical study in 257 subjects
by
Robert Hardi
, Nilesh Mehta
, Jeff O. Gonzalez
, Mahmudul Haq
, Keith Friedenberg
, Haim Shirin
, Gary Gottlieb
, Ravi Ganeshappa
, Jorge-Shmuel Delgado
, Allan Coates
, Vered Richter
, Blake A. Jones
, Steven F. Moss
, Sabine Hazan
, David Gatof
, Dov Abramowitz
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The validity of breath collection bags method in detecting using the novel : a multicenter clinical study in 257 subjects
Journal Article
The validity of breath collection bags method in detecting using the novel : a multicenter clinical study in 257 subjects
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Background and Aim: The BreathID ® Hp urea breath test provides several advantages over other 13 C breath analyzers for the detection of Helicobacter pylori . We evaluated the sensitivity and specificity of a new BreathID ® Hp Lab System (Exalenz Bioscience Ltd, Israel), a 13 C-urea breath test system using breath sampling bags that facilitates multiple testing in a multicenter international clinical study. Methods: A total of 257 subjects with evaluable results for urea breath test, rapid urease test, and histology were enrolled into two study groups: 189 naïve subjects were included in the pre-therapy group, and 68 subjects comprised the post-eradication therapy group. Analytical studies were conducted to evaluate the stability, reproducibility, and repeatability of the 13 C-urea breath test results using a delta over baseline cut-off value of 5. Results: Among the pre-therapy subjects evaluated with the composite results from the rapid urease test and histology/immunohistochemistry, 176 results matched those of the urea breath test, resulting in an overall agreement of 98.3% with a sensitivity of 100% and specificity of 97.9%. In the post-eradication therapy cohort, the overall agreement between the urea breath test and the biopsy diagnosis was 98.5%; the sensitivity of the urea breath test in this cohort was 92.3% and the specificity was 100%. There was uniformly high overall reproducibility (99.48%) of the test results over different batches of breath sample bags, when analyzed on different days and under different storage conditions, showing stability of the breath samples in the breath collection bags Conclusion: The BreathID ® Hp Lab System is a highly accurate and dependable method for the diagnosis of H. pylori infection.
Publisher
SAGE Publishing
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.