MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory
Journal Article

Direct measurement of the muonic content of extensive air showers between\\ {b}{f} 2× 10¹⁸ 2×1018 eV at the Pierre Auger Observatory

2020
Request Book From Autostore and Choose the Collection Method
Overview
Abstract The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between$$2\\times 10^{17}$$2×1017 and$$2\\times 10^{18}$$2×1018 eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at$$10^{{17.5}}\\, {\\mathrm{eV}} $$1017.5eV and$$10^{{18}}\\, {\\mathrm{eV}} $$1018eV . We find that, for the models to explain the data, an increase in the muon density of$$38\\%$$38%$$\\pm 4\\% (12\\%)$$±4%(12%)$$\\pm {}^{21\\%}_{18\\%}$$±18%21% for EPOS-LHC, and of$$50\\% (53\\%)$$50%(53%)$$\\pm 4\\% (13\\%)$$±4%(13%)$$\\pm {}^{23\\%}_{20\\%}$$±20%23% for QGSJetII-04, is respectively needed.
Publisher
SpringerOpen

MBRLCatalogueRelatedBooks