MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain
Journal Article

Baseline Correction of the Human sup.1H MRS Spectrum Using Tsub.2 Selective Differential Operators in the Frequency Domain

2022
Request now and choose the collection method
Overview
The baseline distortion caused by water and fat signals is a crucial issue in the [sup.1]H MRS(I) study of the human brain. This paper suggests an effective and reliable preprocessing technique to calibrate the baseline distortion caused by the water and fat signals exhibited in the MRS spectral signal. For the preprocessing, we designed a T[sub.2]* (or linewidth within the spectral signal) selective filter for the MRS(I) data based on differential filtering within the frequency domain. The number and types for the differential filtering were determined by comparing the T[sub.2]* selectivity profile of each differential operator with the T[sub.2]* profile of the metabolites to be suppressed within the MRS(I) data. In the performance evaluation of the proposed differential filtering, the simulation data for MRS spectral signals were used. Furthermore, the spectral signal of the human [sup.1]H MRSI data obtained by 2D free induction decay chemical shift imaging with a typical water suppression technique was also used in the performance evaluation. The absolute values of the average of the filtered dataset were quantitatively analyzed using the LCModel software. With the suggested T[sub.2]* selective (not frequency selective) filtering technique, in the simulated MRS data, we removed the metabolites from the simulated MRS(I) spectral signal baseline distorted by the water and fat signal observed in the most frequency band. Moreover, in the obtained MRSI data, the quantitative analysis results for the metabolites of interest showed notable improvement in the uncertainty estimation accuracy, the CRLB (Cramer-Rao Lower Bound) levels.
Publisher
MDPI AG
Subject

MBRLCatalogueRelatedBooks