MbrlCatalogueTitleDetail

Do you wish to reserve the book?
以高效液相層析法分析包裝水中低分子量醛類含量
以高效液相層析法分析包裝水中低分子量醛類含量
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
以高效液相層析法分析包裝水中低分子量醛類含量
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
以高效液相層析法分析包裝水中低分子量醛類含量
以高效液相層析法分析包裝水中低分子量醛類含量

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
以高效液相層析法分析包裝水中低分子量醛類含量
以高效液相層析法分析包裝水中低分子量醛類含量
Journal Article

以高效液相層析法分析包裝水中低分子量醛類含量

2003
Request Book From Autostore and Choose the Collection Method
Overview
A high performance liquid chromatographic (HPLC) method for the determination of formaldehyde, acetaldehyde and propionaldehyde in packed drinking water was developed. Aldehydes were derivatized with 0.5 mL DNPH (2,4-dinitrophenylhydrazine) reagent and 0.1 mL 2 M perchloride at 55°C in 60 minutes, then adsorbed in C18 glass cartridge (was performed), eluted with 5 mL acetonitrile ,and finally determined by HPLC. Formaldehyde, acetaldehyde and propionaldehyde-DNPH-derivatives were seperated on a Cosmosil 5C18-MS column by using acetonitrile/D.I. water (55/45, v/v) as a mobile phase, and detected with UV 360 nm. Recovery studies were performed by fortifying D.I. water with formaldehyde, acetaldehyde and propionaldehyde at various concentrations from 2 to 200 ppb. Recovery rates were in the range of 84.4 – 103.2%, 90.2 – 122.1% and 60.8 – 100.4%. The detection limits for all three aldehydes were 1 ppb. Sixty-three packed drinking water samples collected from various markets were analyzed. These results were well
Publisher
衛生福利部食品藥物管理署