Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
以高效液相層析法分析包裝水中低分子量醛類含量
by
蔡佳芬(Tsai, chia-fen)
, 李樹其(Lee, Shu-chi)
, 蕭惠文(Shiau, Huei-wen)
, 周薰修(Chou, Shin-shou)
in
DNPH derivative
/ DNPH衍生物
/ Formaldehyde acetaldehyde
/ MEDLINE
/ Packed drinking water
/ Propionaldehyde
/ SCIE
/ Scopus
/ 丙醛
/ 乙醛
/ 包裝水
/ 甲醛
2003
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
以高效液相層析法分析包裝水中低分子量醛類含量
by
蔡佳芬(Tsai, chia-fen)
, 李樹其(Lee, Shu-chi)
, 蕭惠文(Shiau, Huei-wen)
, 周薰修(Chou, Shin-shou)
in
DNPH derivative
/ DNPH衍生物
/ Formaldehyde acetaldehyde
/ MEDLINE
/ Packed drinking water
/ Propionaldehyde
/ SCIE
/ Scopus
/ 丙醛
/ 乙醛
/ 包裝水
/ 甲醛
2003
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
以高效液相層析法分析包裝水中低分子量醛類含量
2003
Request Book From Autostore
and Choose the Collection Method
Overview
A high performance liquid chromatographic (HPLC) method for the determination of formaldehyde, acetaldehyde and propionaldehyde in packed drinking water was developed. Aldehydes were derivatized with 0.5 mL DNPH (2,4-dinitrophenylhydrazine) reagent and 0.1 mL 2 M perchloride at 55°C in 60 minutes, then adsorbed in C18 glass cartridge (was performed), eluted with 5 mL acetonitrile ,and finally determined by HPLC. Formaldehyde, acetaldehyde and propionaldehyde-DNPH-derivatives were seperated on a Cosmosil 5C18-MS column by using acetonitrile/D.I. water (55/45, v/v) as a mobile phase, and detected with UV 360 nm. Recovery studies were performed by fortifying D.I. water with formaldehyde, acetaldehyde and propionaldehyde at various concentrations from 2 to 200 ppb. Recovery rates were in the range of 84.4 – 103.2%, 90.2 – 122.1% and 60.8 – 100.4%. The detection limits for all three aldehydes were 1 ppb. Sixty-three packed drinking water samples collected from various markets were analyzed. These results were well
This website uses cookies to ensure you get the best experience on our website.