Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
DDD-Schrittmacher-Implantation bei einem 7 Wochen alten Säugling: Epikardiale Elektroden mit intrapleuraler Aggregatlage
by
Nürnberg, J-h
, Hetzer, R
, Hübler, M
, Senft, G
, Lange, P E
2001
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
DDD-Schrittmacher-Implantation bei einem 7 Wochen alten Säugling: Epikardiale Elektroden mit intrapleuraler Aggregatlage
by
Nürnberg, J-h
, Hetzer, R
, Hübler, M
, Senft, G
, Lange, P E
2001
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
DDD-Schrittmacher-Implantation bei einem 7 Wochen alten Säugling: Epikardiale Elektroden mit intrapleuraler Aggregatlage
Journal Article
DDD-Schrittmacher-Implantation bei einem 7 Wochen alten Säugling: Epikardiale Elektroden mit intrapleuraler Aggregatlage
2001
Request Book From Autostore
and Choose the Collection Method
Overview
Permanent pacing for complete heart block in newborns and small infants is a challenge concerning the mismatch between body size and pacemaker dimensions. As the abdominal position of the large pacemaker carries a considerable risk of healing disturbances, the intrapleural position of single chamber pacemakers is accepted as well. We report about a 7 week old infant with congestive heart failure due to a complete atrioventricular septal defect. The immature valve tissue led to recurrent, severe mitral valve incompetence and necessitated several valvuloplasty procedures and finally the implantation of a mechanical prothesis. Because of a postoperative complete heart block, a dual chamber pacemaker with epicardial steroid-eluting bipolar leads was implanted without specific fixation into the right pleural cavity during delayed sternal closure to ensure atrioventricular synchrony. Despite the capacious implant, adverse effects on hemodynamics and pulmonary function were not observed and the infant thrived normally. The DDD function of the pacemaker allowed the utilization of the infant's complete heart rate spectrum without restrictions due to the technically limited upper tracking rate of 180bpm.[PUBLICATION ABSTRACT]
Publisher
Springer Nature B.V
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.