MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage
Dissertation

Thermoeconomic analysis of cogenerated refuse energy recovery plant with thermal storage

1988
Request Book From Autostore and Choose the Collection Method
Overview
This thesis develops thermoeconomic (second law and present worth) analysis and investigates the feasibility of employing thermal storage for cogenerated refuse energy recovery using mass-burning water-wall incinerators and topping steam turbines. A typical design is envisioned to be modular in nature so that it may be applied to various size loads without major engineering modifications. Each module is rated at 150 tpd of refuse capacity, 750 kW of electrical power, and 26,200 lbm/hr (11,900 kg/hr) of 150 psig (1140 kPa absolute) steam. As an option, condensing turbines are considered to receive unused process steam in the case of reduced steam load. The results indicate that this option is not economically feasible for a typical off-peak utility-purchase rate which leads to the idea of storing the excess energy during off-peak periods and recuperating it during peak periods. Sensible thermal storage is considered in rectangular cross-sectional channels through which is passed unused process steam during the storage period and feedwater during the recovery period. In determining the optimum storage configuration, it is found that the economic feasibility is a function of of mass and specific heat of the material and surface area of the channel as well as cost of material and fabrication. Economic considerations included typical cash flows of capital charges, steam and electrical energy revenues, refuse tipping fee, operation and maintenance costs, and income taxes. Cast concrete is determined to be a potentially attractive storage medium.
Publisher
ProQuest Dissertations & Theses
ISBN
9798207067681