Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
The use of a blended polyimide/polyester (PI/PE) felt for liquid filtration
by
Flaherty, Ryan M
in
Industrial engineering
2005
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The use of a blended polyimide/polyester (PI/PE) felt for liquid filtration
by
Flaherty, Ryan M
in
Industrial engineering
2005
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The use of a blended polyimide/polyester (PI/PE) felt for liquid filtration
Dissertation
The use of a blended polyimide/polyester (PI/PE) felt for liquid filtration
2005
Request Book From Autostore
and Choose the Collection Method
Overview
The purpose of this project was to examine whether a polyimide/polyester composite felt can be used in four liquid filtration processes for the customer, Imerys, International. This was determined by examining its use in the filtering of four different sized products. The trial composite felt was tested against a total 21 other felts based on five test parameters: total filtrate volume, total amount of wet cake produced, percent cake solids, total amount of dry cake produced, and the percent filtrate solids. The hypothesis stated that the trial felt would work well enough in laboratory testing for two of the four products and could be recommended for full scale testing in these two applications. The two products hypothesized to succeed were the Supermite and Atomite products, which have the smallest average particle size of the four. The results of the laboratory testing concluded that the hypothesis was not supported. Although the trial felt filtered both the Snowflake and Supermite products well, they were not the two smallest resulting products. However, the product did perform well enough in these two areas to be recommended for full scale testing, with only the Supermite product making final approvals for pilot plant testing.
This website uses cookies to ensure you get the best experience on our website.