MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils
Paper

Low-Threshold Response of a Scintillating Xenon Bubble Chamber to Nuclear and Electronic Recoils

2024
Request Book From Autostore and Choose the Collection Method
Overview
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by \\(\\)-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ~1 keV nuclear recoils while remaining insensitive to bubble nucleation by \\(\\)-rays. A robust calibration of the chamber's nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by \\(\\)-ray-induced Auger cascades, with a limit of \\(<1.110^-6\\) set at 0.50 keV, the lowest thermodynamic threshold explored.
Publisher
Cornell University Library, arXiv.org