MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection
Paper

Charge-exchange measurements of high-energy fast ions in LHD using negative-ion neutral beam injection

2024
Request Book From Autostore and Choose the Collection Method
Overview
A new sightline geometry for the fast-ion D-alpha (FIDA) diagnostic on the Large Helical Device (LHD) has been confirmed to measure signals for high-energy fast ions produced by negative-ion neutral beam injection. The newly installed sightline uses a 180 keV tangential negative-ion neutral beamline as the active source. Due to the small angle between the beamline and FIDA sightline, the relative velocity between fast ions and injected neutrals is small. This allows for high-energy fast ions just below the beam injection energy to produce measurable Doppler-shifted FIDA emission. Experiments were conducted at LHD in order to compare the new sightline, which views a high-energy negative-ion tangential beamline, and the old sightline, which views a low-energy perpendicular positive-ion neutral beamline. The measured FIDA signal is validated against predictions from the synthetic fast-ion diagnostic code FIDASIM with a distribution function modelled by the 5D transport code GNET. The results of the experiment confirm that reducing the viewing angle with a tangential active beam allows FIDA diagnostic to view high-energy fast ions with a sufficient signal-to-noise ratio.