A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case
by
Massaccesi, Mariangela
, Boldrini, Luca
, Teodoli, Stefania
, Cellini, Francesco
, Balducci, Mario
, Fionda, Bruno
, Valentini, Vincenzo
, Cusumano, Davide
, Dinapoli, Nicola
, Azario, Luigi
, Mattiucci, Gian Carlo
in
Technical Note
/ Technical Notes
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case
by
Massaccesi, Mariangela
, Boldrini, Luca
, Teodoli, Stefania
, Cellini, Francesco
, Balducci, Mario
, Fionda, Bruno
, Valentini, Vincenzo
, Cusumano, Davide
, Dinapoli, Nicola
, Azario, Luigi
, Mattiucci, Gian Carlo
in
Technical Note
/ Technical Notes
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case
by
Massaccesi, Mariangela
, Boldrini, Luca
, Teodoli, Stefania
, Cellini, Francesco
, Balducci, Mario
, Fionda, Bruno
, Valentini, Vincenzo
, Cusumano, Davide
, Dinapoli, Nicola
, Azario, Luigi
, Mattiucci, Gian Carlo
in
Technical Note
/ Technical Notes
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case
Journal Article
A new frontier of image guidance: Organs at risk avoidance with MRI‐guided respiratory‐gated intensity modulated radiotherapy: Technical note and report of a case
2019
Request Book From Autostore
and Choose the Collection Method
Overview
The case of a 50‐year‐old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri‐60‐Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery and a respiratory gating protocol was applied for the different breathing phases (Free Breathing, Deep Inspiration Breath Hold and Final Expiration Breath Hold). Three intensity modulated radiation therapy (IMRT) plans were calculated and Final Expiration Breath Hold plan was finally selected due to the absence of PTV coverage differences and better organs at risk sparing (i.e. kidneys). This case report suggests that organs at risk avoidance with MRI‐guided respiratory‐gated Radiotherapy is feasible and particularly advantageous whenever sparing the organs at risk is of utmost dosimetric or clinical importance.