Efficacy of chlorin dioxide wipes in disinfecting airway devices contaminated with Covid-19
2023
Reprocessing and disinfecting endoscopes is a routine practice in otolaryngology. An effective, safe, and rapid disinfection technique is essential during the COVID-19 pandemic.
To validate the efficacy of chlorine dioxide wipes in disinfecting three types of airway endoscopes contaminated with COVID-19-positive patient secretions.
Chlorine dioxide wipes were tested on rigid nasal endoscopes, laryngoscope blades, and flexible bronchoscopes. The endoscopes were disinfected using the wipes after exposure to COVID-19-positive patients. The tested scope was included in the study if the post procedure pre disinfection swab was positive for COVID-19 virus using RT-PCR. We analyzed 38 samples for 19 subjects (scopes) pre and post disinfection with chlorine dioxide wipes from July 2021 to February 2022.
A total of four rigid endoscopes, four flexible bronchoscopes, and four laryngoscopes were included in the study which represent 24 pre and post disinfection swabs. The others were excluded because of negative pre disinfection swab. All the post disinfection PCR swab results were negative.
Chlorine dioxide is a convenient, fast, and effective disinfection technique for COVID-19-contaminated airway endoscopes.
Journal Article
Elevated plasma level of the glycolysis byproduct methylglyoxal on admission is an independent biomarker of mortality in ICU COVID-19 patients
by
Alali, Rudaynah A.
,
Alshakhs, Marai N.
,
Almulaify, Mohammed S.
in
631/326/596/4130
,
631/80/304
,
692/53/2423
2022
Biomarkers to identify ICU COVID-19 patients at high risk for mortality are urgently needed for therapeutic care and management. Here we found plasma levels of the glycolysis byproduct methylglyoxal (MG) were 4.4-fold higher in ICU patients upon admission that later died (n = 33), and 1.7-fold higher in ICU patients that survived (n = 32),compared to uninfected controls (n = 30). The increased MG in patients that died correlated inversely with the levels of the MG-degrading enzyme glyoxalase-1 (
r
2
= − 0.50), and its co-factor glutathione (
r
2
= − 0.63), and positively with monocytes (
r
2
= 0.29). The inflammation markers, SSAO (
r
2
= 0.52), TNF-α (
r
2
= 0.41), IL-1β (
r
2
= 0.25), CRP (
r
2
= 0.26) also correlated positively with MG. Logistic regression analysis provides evidence of a significant relationship between the elevated MG upon admission into ICU and death (P < 0.0001), with 42% of the death variability explained. From these data we conclude that elevated plasma MG on admission is a novel independent biomarker that predicts mortality in ICU COVID-19 patients.
Journal Article
Academic achievement and gender among adult critical care program directors
by
Vasilopoulos, Terrie
,
Almualim, Mohammed
,
Santos, Rogerio Almeida Moreno
in
Academic achievement
,
Accreditation
,
Anesthesiology
2021
Accreditation Council for Graduate Medical Education (ACGME) program director (PD) qualifications includes scholarly activity with demonstrated academic productivity and dissemination. Our hypothesis: academic productivity among adult critical care medicine (CCM) fellowship PDs is affected by gender with women having lower productivity.
PDs in 39 institutions with CCM fellowships in anesthesiology, surgery, and pulmonary medicine were analyzed using data from ACGME website, PubMed, and NIH Research Portfolio Online Reporting Tools. Primary outcomes were total publications and h-index. Secondary outcomes included NIH funding and past five year publications. Independent variables and covariates included gender, academic rank, year appointed as program director, years certified in CCM, and specialty.
PDs who were women had fewer total publications (median: 13 vs: 20, p = 0.030), past 5 years publications (median: 6 vs median: 9; p = 0.025), and less NIH funding (12% vs 32%; p = 0.046) compared to men. In exploratory analyses stratified by rank, assistant professor ranked women had fewer total (p = 0.027) and recent publications (p = 0.031) compared to men.
Women who were PDs had fewer publications and less NIH funding compared to men with differences in publications more prominent in early career faculty.
•Fellowship program directors who were women had fewer publications than men.•Fellowship program directors who were women had less NIH funding than men.•Assistant professor ranked women had fewer total and recent publications than men.
Journal Article
Pulsed dose radiofrequency before ablation of medial branch of the lumbar dorsal ramus for zygapophyseal joint pain reduces post-procedural pain
2016
Background: One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. Objectives: The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. Study Design: This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. Setting: University hospital. Methods: Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on postprocedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Results: Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. Limitations: These interventions were carried out by one board accredited pain physician at one center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Conclusion: Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Key words: Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint
Journal Article
Evaluation of Interaction between a Spinal Cord Stimulator and Implanted CardioverterDefibrillator in a Swine Model,Evaluation of interaction between a SpinalCord stimulator and implanted cardioverter defibrillator in a swine model
2013
Background: Spinal cord stimulators (SCS) have been used for many years to treat a myriad of chronic pain conditions using electrical signals to diminish the perception of a painful stimulus. Because of the electrical nature of the devices, there is a concern about the potential for electromagnetic interaction between the device and lifesaving cardiac implantable cardiovertersdefibrillators (ICVD). Objective: The purpose of this study was to use a swine model to evaluate the potential for interaction between an implanted SCS and ICVD using the closest possible proximity, highest stimulation settings, and most sensitive ICVD settings. Methods: A pig was anesthetized and subsequently an ICVD and ICVD lead (Cogni 100-D and Endotak Reliance®, Boston Scientific, Natick, MA) were placed into the right prepectoral region and the right ventricle, respectively. An SCS (50 cm linear ST Precision Plu octad electrode lead [Boston Scientific, Valencia, CA] with 3 mm wide contacts spaced one mm apart) was implanted using fluoroscopic guidance into the posterior epidural space. Remote interrogation and programming of the ICVD were performed while the SCS lead was placed in as close proximity as possible, using fluoroscopy to guide the final position of the SCS electrode. After confirming that both systems were working, appropriately 9 stimulating configurations of varying current, pulse width, and frequency, including maximal settings, were delivered through the SCS. The effects on the ICVD were recorded at 2 sensitivity settings. Results: None of the tested SCS configurations caused interference with the proper functioning of the ICVD. Limitations: The anatomical proximity of the posterior epidural space and right ventricle of the swine is different from humans. While the entire pacer, including generator, was imbedded in a subcutaneous pocket, an implantable pulse generator for the SCS was not implanted, which did not allow us to study if any damage or a resetting of settings had occurred to the generator. Only one manufacturer was used in this study. Also, this study was performed in an anesthetized pig and the anatomical positions remained static. Realistically, changes in position of the devices would occur in patients who perform activities of daily living, and this can potentially shorten the distance between the 2 leads causing adverse interaction. Conclusion: This study clearly demonstrated the feasibility of the 2 devices coexisting and functioning appropriately in an animal model using an ICVD and SCS donated by Boston Scientific. Further studies are needed to elucidate restrictions, optimal settings and parameters in a human setting. Key words: Spinal cord stimulator, interaction, implantable cardioverter defibrillator, pacemaker, swine model, cross-talk.
Journal Article
Evaluation of interaction between a spinal cord stimulator and implanted cardioverter-defibrillator in a swine model
by
Chaiban, Gassan M
,
Almualim, Mohammed
,
Atallah, Joseph
in
Animals
,
Chronic Pain - therapy
,
Defibrillators
2013
Spinal cord stimulators (SCS) have been used for many years to treat a myriad of chronic pain conditions using electrical signals to diminish the perception of a painful stimulus. Because of the electrical nature of the devices, there is a concern about the potential for electromagnetic interaction between the device and lifesaving cardiac implantable cardioverters-defibrillators (ICVD).
The purpose of this study was to use a swine model to evaluate the potential for interaction between an implanted SCS and ICVD using the closest possible proximity, highest stimulation settings, and most sensitive ICVD settings.
A pig was anesthetized and subsequently an ICVD and ICVD lead (Cogni 100-D and Endotak Reliance®, Boston Scientific, Natick, MA) were placed into the right prepectoral region and the right ventricle, respectively. An SCS (50 cm linear ST Precision Plu octad electrode lead [Boston Scientific, Valencia, CA] with 3 mm wide contacts spaced one mm apart- ) was implanted using fluoroscopic guidance into the posterior epidural space. Remote interrogation and programming of the ICVD were performed while the SCS lead was placed in as close proximity as possible, using fluoroscopy to guide the final position of the SCS electrode. After confirming that both systems were working, appropriately 9 stimulating configurations of varying current, pulse width, and frequency, including maximal settings, were delivered through the SCS. The effects on the ICVD were recorded at 2 sensitivity settings.
None of the tested SCS configurations caused interference with the proper functioning of the ICVD.
The anatomical proximity of the posterior epidural space and right ventricle of the swine is different from humans. While the entire pacer, including generator, was imbedded in a subcutaneous pocket, an implantable pulse generator for the SCS was not implanted, which did not allow us to study if any damage or a resetting of settings had occurred to the generator. Only one manufacturer was used in this study. Also, this study was performed in an anesthetized pig and the anatomical positions remained static. Realistically, changes in position of the devices would occur in patients who perform activities of daily living, and this can potentially shorten the distance between the 2 leads causing adverse interaction.
This study clearly demonstrated the feasibility of the 2 devices coexisting and functioning appropriately in an animal model using an ICVD and SCS donated by Boston Scientific. Further studies are needed to elucidate restrictions, optimal settings and parameters in a human setting.
Journal Article
Successful treatment of occipital neuralgia with implantable peripheral nerve stimulation in a pacemaker-dependent patient
2014
Peripheral nerve stimulation has been used to treat patients with occipital nerve-related chronic headaches who have been unsuccessful with less invasive therapeutic approaches. Patients with pacemaker-dependent cardiac conduction abnormalities require unique consideration prior to the implantation of peripheral nerve stimulators because the placement of the devices may lead to failure of the systems secondary to electromagnetic interference or crosstalk between the devices.
An 86-year-old female who suffered from chronic right-sided cervicogenic headaches and neck pain had received only temporary relief from previous treatments. Additional comorbidities included longstanding pacemaker-dependent atrioventricular node conduction disease. Because the extent to which nerve stimulators electrically interact with pacemakers is unclear, we tunneled the leads to the lumbar region of the back and placed the generator on the contralateral side to the pacemaker to minimize the chance that the 2 devices would interfere. The patient has remained pain free for 1 year since implantation.
Although no current published trials evaluate the degree of interference between medical devices, case reports increasingly suggest that simultaneous implantation of a spinal cord stimulator and pacemaker is safe as long as precautions are taken and the devices are checked periodically, particularly when the devices are adjusted.
Journal Article