Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
101
result(s) for
"Bohner Georg"
Sort by:
Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging
by
Kendlbacher, Paul
,
Tkatschenko Dimitri
,
Czabanka Marcus
in
Accuracy
,
Computed tomography
,
Patients
2020
PurposePercutaneous paraspinal pedicle screw implantation (PPSI) reduces soft tissue trauma, blood loss, and postoperative pain but remains technically challenging and associated with radiation exposure and implant-related artefacts. Here, we determined the feasibility, screw accessibility, and the accuracy of navigated PPSI in the thoraco-lumbar sacral spine using intraoperative computed tomography (iCT) and robotic cone-beam CT (CBCT) imaging.MethodsBetween 2015 and 2018, 465 percutaneous paraspinal pedicle screws were implanted in 75 patients using iCT- or CBCT-based spinal navigation with 230 screws connected to rod reducers during screw assessment imaging (iCT 198; CBCT 32). Clinical and demographic data, intraoperative screw accessibility, and screw accuracy were analyzed and compared to a case-matched cohort of 75 patients undergoing navigated implantation of 481 pedicle screws through an open midline approach.ResultsBoth iCT and CBCT permitted reliable assessment of each implanted screw, regardless of artifacts caused by rod reducers. Although overall accuracy for correct placement was comparable between PPSI and open surgery (PPSI 96.6%; Open 94.2%), PPSI compared favorably to open surgery regarding complete placement within the pedicle (PPSI 90.1%; Open 75.1%; p < 0.0001), regional placement accuracy in the lumbar (PPSI 97.8%; Open 91.5%; p < 0.001), and lumbar-sacral spine (PPSI 100%; Open 81.2%; p < 0.05), next to the duration of surgery and length of hospitalization.ConclusionsPPSI with iCT- and CBCT-based spinal navigation improves the accuracy, safety, and workflow of navigated spinal instrumentation. Next, a cost-effectiveness and outcome analysis should determine whether iCT and CBCT imaging are truly economically justified.Graphic abstractThese slides can be retrieved under Electronic Supplementary Material.
Journal Article
Direct puncture of the carotid artery as a bailout vascular access technique for mechanical thrombectomy in acute ischemic stroke—the revival of an old technique in a modern setting
by
Liebig, Thomas
,
Kleine, Justus F.
,
Bohner, Georg
in
Blood vessels
,
Carotid artery
,
Catheterization
2021
Purpose
To describe our single-center experience of mechanical thrombectomy (MTE) via a direct carotid puncture (DCP) with regard to indication, time metrics, procedural details, as well as safety and efficacy aspects.
Methods
DCP thrombectomy cases performed at our center were retrospectively identified from a prospectively maintained institutional MTE database. Various patient (age, sex, stroke cause, comorbidities), clinical (NIHSS, mRS), imaging (occlusion site, ASPECT score), procedural (indication for DCP, time from DCP to reperfusion, materials used, technical nuances), and outcome data (NIHSS, mRS) were tabulated.
Results
Among 715 anterior circulation MTEs, 12 DCP-MTEs were identified and analyzed. Nine were left-sided M1 occlusions, one right-sided M1 occlusion, and two right-sided M2 occlusions. DCP was successfully carried out in 91.7%; TICI 2b/3-recanalization was achieved in 83.3% via direct lesional aspiration and/or stent-retrieval techniques. Median time from DCP to reperfusion was 23 min. Indications included futile transfemoral catheterization attempts of the cervical target vessels as well as iliac occlusive disease. Neck hematoma occurred in 2 patients, none of which required further therapy.
Conclusion
MTE via DCP in these highly selected patients was reasonably safe, fast, and efficient. It thus represents a valuable technical extension of MTE, especially in patients with difficult access.
Journal Article
Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
2021
To evaluate the diagnostic performance of magnetic resonance imaging (MRI) alone in comparison to positron emission tomography/ magnetic resonance imaging (PET/MRI) in patients with meningiomas. 57 patients with a total of 112 meningiomas of the brain were included. PET/MRI, including a fully diagnostic contrast enhanced MRI and PET, were acquired. PET/MRI was used as reference standard. The size and location of meningiomas was recorded. Likelihood-ratio chi-square tests were used to calculate p-values within logistic regression in order to compare different models. A multi-level logistic regression was applied to comply the hierarchical data structure. Multi-level regression adjusts for clustering in data was performed. The majority (n = 103) of meningiomas could be identified based on standard MRI sequences compared to PET/MRI. MRI alone achieved a sensitivity of 95% (95% CI 0.78, 0.99) and specificity of 88% (95% CI 0.58, 0.98). Based on intensity of contrast medium uptake, 97 meningiomas could be diagnosed with intense uptake (93.75%). Sensitivity was lowest with 74% for meningiomas < 0.5 cm
3
, high with 95% for meningiomas > 2cm
3
and highest with 100% for meningiomas 0.5–1.0 cm
3
. Petroclival meningiomas showed lowest sensitivity with 88% compared to sphenoidal meningiomas with 94% and orbital meningiomas with 100%. Specificity of meningioma diagnostic with MRI was high with 100% for sphenoidal and hemispherical-dural meningiomas and meningiomas with 0.5–1.0 and 1.0–2.0 cm
3
. Overall MRI enables reliable detection of meningiomas compared to PET/MRI. PET/MRI imaging offers highest sensitivity and specificity for small or difficult located meningiomas.
Journal Article
Differential activation of the dorsal striatum by high-calorie visual food stimuli in obese individuals
2007
The neural systems regulating food intake in obese individuals remain poorly understood. Previous studies applied positron emission tomography and manipulated hunger and satiety to investigate differences in appetitive processing between obese and normal-weight individuals. However, it is not known whether manipulation of stimulus value may yield different neural activity in obese as compared to control subjects when intrinsic physiological states are kept constant. We used functional magnetic resonance imaging to investigate 13 obese and 13 normal-weight subjects and manipulated food motivation by presenting visual food stimuli differing in their caloric content and energy density.
In contrast to controls, obese women selectively activated the dorsal striatum while viewing high-caloric foods. Moreover, in the high-calorie condition body mass index (BMI) predicted activation in the dorsal striatum, anterior insula, claustrum, posterior cingulate, postcentral and lateral orbitofrontal cortex.
The results indicate that in obese individuals simple visual stimulation with food stimuli activates regions related to reward anticipation and habit learning (dorsal striatum). Additionally, high-calorie food images yielded BMI-dependent activations in regions associated with taste information processing (anterior insula and lateral orbitofrontal cortex), motivation (orbitofrontal cortex), emotion as well as memory functions (posterior cingulate).
Collectively, the results suggest that the observed activation is independent of the physiological states of hunger and satiation, and thus may contribute to pathological overeating and obesity. Some of the observed activations (dorsal striatum, orbitofrontal cortex) are likely to be dopamine-mediated.
Journal Article
Inconsistency of AI in intracranial aneurysm detection with varying dose and image reconstruction
2025
Scanner-related changes in data quality are common in medical imaging, yet monitoring their impact on diagnostic AI performance remains challenging. In this study, we performed standardized consistency testing of an FDA-cleared and CE-marked AI for triage and notification of intracranial aneurysms across changes in image data quality caused by dose and image reconstruction. Our assessment was based on repeated examinations of a head CT phantom designed for AI evaluation, replicating a patient with three intracranial aneurysms in the anterior, middle and posterior circulation. We show that the AI maintains stable performance within the medium dose range but produces inconsistent results at reduced dose and, unexpectedly, at higher dose when filtered back projection is used. Data quality standards required for AI are stricter than those for neuroradiologists, who report higher aneurysm visibility rates and experience performance degradation only at substantially lower doses, with no decline at higher doses.
Journal Article
Intraoperative CT and cone-beam CT imaging for minimally invasive evacuation of spontaneous intracerebral hemorrhage
by
Kendlbacher, Paul
,
Czabanka Marcus
,
Bohner Georg
in
Computed tomography
,
Endoscopy
,
Feasibility studies
2020
BackgroundMinimally invasive surgery (MIS) for evacuation of spontaneous intracerebral hemorrhage (ICH) has shown promise but there remains a need for intraoperative performance assessment considering the wide range of evacuation effectiveness. In this feasibility study, we analyzed the benefit of intraoperative 3-dimensional imaging during navigated endoscopy-assisted ICH evacuation by mechanical clot fragmentation and aspiration.Methods18 patients with superficial or deep supratentorial ICH underwent MIS for clot evacuation followed by intraoperative computerized tomography (iCT) or cone-beam CT (CBCT) imaging. Eligibility for MIS required (a) availability of intraoperative iCT or CBCT, (b) spontaneous lobar or deep ICH without vascular pathology, (c) a stable ICH volume (20–90 ml), (d) a reduced level of consciousness (GCS 5–14), and (e) a premorbid mRS ≤ 1. Demographic, clinical, and radiographic patient data were analyzed by two independent observers.ResultsNine female and 9 male patients with a median age of 76 years (42–85) presented with an ICH score of 3 (1–4), GCS of 10 (5–14) and ICH volume of 54 ± 26 ml. Clot fragmentation and aspiration was feasible in all cases and intraoperative imaging determined an overall evacuation rate of 80 ± 19% (residual hematoma volume: 13 ± 17 ml; p < 0.0001 vs. Pre-OP). Based on the intraoperative imaging results, 1/3rd of all patients underwent an immediate re-aspiration attempt. No patient experienced hemorrhagic complications or required conversion to open craniotomy. However, routine postoperative CT imaging revealed early hematoma re-expansion with an adjusted evacuation rate of 59 ± 30% (residual hematoma volume: 26 ± 37 ml; p < 0.001 vs. Pre-OP).ConclusionsRoutine utilization of iCT or CBCT imaging in MIS for ICH permits direct surgical performance assessment and the chance for immediate re-aspiration, which may optimize targeting of an ideal residual hematoma volume and reduce secondary revision rates.
Journal Article
Quantitative biparametric analysis of hybrid 18F-FET PET/MR-neuroimaging for differentiation between treatment response and recurrent glioma
2019
We investigated the diagnostic potential of simultaneous
18
F-FET PET/MR-imaging for differentiation between recurrent glioma and post-treatment related effects (PTRE) using quantitative volumetric (3D-VOI) lesion analysis. In this retrospective study, a total of 42 patients including 32 patients with histologically proven glioma relapse and 10 patients with PTRE (histopathologic follow-up, n = 4, serial imaging follow-up, n = 6) were evaluated regarding recurrence. PET/MR-imaging was semi-automatically analysed based on FET tracer uptake using conservative SUV thresholding (isocontour 80%) with emphasis on the metabolically most active regions. Mean (relative) apparent diffusion coefficient (ADCmean, rADCmean), standardised-uptake-value (SUV) including target-to-background (TBR) ratio were determined. Glioma relapse presented higher ADCmean (MD ± SE, 284 ± 91, p = 0.003) and TBRmax (MD ± SE, 1.10 ± 0.45, p = 0.02) values than treatment-related changes. Both ADCmean (AUC ± SE = 0.82 ± 0.07, p-value < 0.001) and TBRmax (AUC ± SE = 0.81 ± 0.08, p-value < 0.001) achieved reliable diagnostic performance in differentiating glioma recurrence from PTRE. Bivariate analysis based on a combination of ADCmean and TBRmax demonstrated highest diagnostic accuracy (AUC ± SE = 0.90 ± 0.05, p-value < 0.001), improving clinical (false negative and false positive) classification. In conclusion, biparametric analysis using DWI and FET PET, both providing distinct information regarding the underlying pathophysiology, presented best diagnostic accuracy and clinical benefit in differentiating recurrent glioma from treatment-related changes.
Journal Article
Clinical and Radiological Spectrum of Posterior Reversible Encephalopathy Syndrome: Does Age Make a Difference? – A Retrospective Comparison between Adult and Pediatric Patients
2014
Posterior reversible encephalopathy syndrome (PRES) is a serious and increasingly recognized disorder, but data from observational studies on clinicoradiological differences between etiologies and age groups are limited. In this study, we aimed to investigate the clinical and imaging characteristics of PRES in children compared to adults in a large cohort.
We retrospectively reviewed the radiological report data bases between January 1999 and August 2012 for patients with PRES (total of 110 patients). Patients fulfilling the criteria for PRES after detailed investigation of clinical charts and imaging studies were separated into children (<18 years) and adults (≥18 years). Various imaging features at onset of symptoms and on follow-up as well as clinical and paraclinical data were analyzed.
A total of 19 pediatric and 91 adult patients with PRES were included into the study. In pediatric PRES patients, seizures were significantly more frequent as initial PRES-related symptom (p = 0.01). In addition, in children the superior frontal sulcus topographic lesion pattern occurred as frequent as the parieto-occipital one and was significantly more prevalent than in adults (p = 0.02). In contrast, in adults visual disturbances tended to occur more frequently than in children (p = 0.05). Also, severity of edema tended to be greater in adults than in children (p = 0.07).
In our PRES cohort, we found relevant clinicoradiological differences between pediatric and adult PRES patients. However, prospective studies are warranted to establish factors that are specifically associated with pediatric PRES.
Journal Article
Navigation accuracy and assessability of carbon fiber-reinforced PEEK instrumentation with multimodal intraoperative imaging in spinal oncology
by
Onken, Julia
,
Bohner, Georg
,
Czabanka, Marcus
in
692/700/1421/1846
,
692/700/1421/2025
,
692/700/1421/2770
2022
Radiolucent carbon-fiber reinforced PEEK (CFRP) implants have helped improve oncological follow-up and radiation therapy. Here, we investigated the performance of 3D intraoperative imaging and navigation systems for instrumentation and precision assessment of CFRP pedicle screws across the thoraco-lumbar spine. Thirty-three patients with spinal tumors underwent navigated CFRP instrumentation with intraoperative CT (iCT), robotic cone-beam CT (rCBCT) or cone-beam CT (CBCT) imaging. Two different navigation systems were used for iCT-/rCBCT- and CBCT-based navigation. Demographic, clinical and outcome data was assessed. Four blinded observers rated image quality, assessability and accuracy of CFRP pedicle screws. Inter-observer reliability was determined with Fleiss` Kappa analysis. Between 2018 and 2021, 243 CFRP screws were implanted (iCT:93, rCBCT: 99, CBCT: 51), of which 13 were non-assessable (iCT: 1, rCBCT: 9, CBCT: 3; *p = 0.0475; iCT vs. rCBCT). Navigation accuracy was highest using iCT (74%), followed by rCBCT (69%) and CBCT (49%) (*p = 0.0064; iCT vs. CBCT and rCBCT vs. CBCT). All observers rated iCT image quality higher than rCBCT/CBCT image quality (*p < 0.01) but relevant pedicle breaches were reliably identified with substantial agreement between all observers regardless of the imaging modality. Navigation accuracy for CFRP pedicle screws was considerably lower than expected from reports on titanium implants and CT may be best for reliable assessment of CFRP materials.
Journal Article
CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): results of 1-month and 1-year assessment of rebleeding protection and clinical safety in a multicenter study
2022
BackgroundThe primary goal of the CLARYS study is to assess the protection against rebleeding when treating ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) device.MethodsThe CLARYS study is a prospective, multicenter study conducted in 13 European centers. Patients with ruptured bifurcation aneurysms were consecutively included between February 2016 and September 2017. The primary endpoint was defined as the rebleeding rate of the target aneurysm treated with the WEB within 30 days postprocedure. Secondary endpoints included periprocedural and postprocedural adverse events, total procedure and fluoroscopy times, and modified Rankin Scale score at 1 month and 1 year.ResultsSixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. A WEB device was successfully implanted in 93.3%. The rebleeding rate at 1 month and 1 year was 0%. The mean fluoroscopy time was 27.0 min. Twenty-three periprocedural complications were observed in 18 patients and resolved without sequelae in 16 patients. Two of these complications were attributed to the procedure and/or the use of the WEB, leading to a procedure/device-related intraoperative complication rate of 3.3%. Overall mortality at 1 month and 1 year was 1.7% and 3.8%, respectively and overall morbidity at 1 month and 1 year was 15% and 9.6%, respectively. WEB-related 1-month and 1-year morbidity and mortality was 0%.ConclusionsThe interim results of CLARYS show that the endovascular treatment of ruptured bifurcation aneurysms with the WEB is safe and effective and, in particular, provides effective protection against rebleeding. It may induce profound change in the endovascular management of ruptured bifurcation aneurysms.
Journal Article