Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
24 result(s) for "Chatzimavroudis, G."
Sort by:
Outcomes of posterior component separation with transversus abdominis release (TAR) in large and other complex ventral hernias: a single-surgeon experience
PurposeOver the last years, great advances in the repair of abdominal wall hernias have dramatically improved patients’ outcomes. Especially for large and other complex ventral hernias, the application of component separation techniques has been a landmark in their successful management. The aim of this study is to present our experience with the posterior component separation with transversus abdominis release (TAR) in patients with these demanding ventral hernias.MethodsA retrospective analysis of prospectively collected data of all patients who underwent elective ventral hernia repair with TAR between January 2016 and December 2019 was performed. Preoperative, intraoperative, and postoperative data were analyzed.ResultsA total of 125 patients with large and other complex ventral hernias were included in the final analysis. More than 80% of patients had one or more comorbidities. Of all patients, 116 (92.8%) had a history of previous abdominal surgery, 27 (21.6%) had a history of SSI and nine (7.2%) had active fistulas. Postoperatively, SSOs were presented in 11 patients (8.8%), including three cases of SSI. Neither mesh infection occurred, nor mesh excision required. With a mean follow-up of 2.5 years, only one recurrence was observed.ConclusionsWith a wound complication rate of less than 9% and a recurrence rate of less than 1%, our results show that TAR is a reliable, safe and effective technique for the repair of massive and other complex ventral hernias. The combination of knowledge of the abdominal wall anatomy at a proficient level, proper training, and adoption of a strict prehabilitation program are considered prerequisites for the successful management of such demanding hernias.
Paraduodenal hernias: a systematic review of the literature
PurposeParaduodenal hernias (PDH), also called mesocolic hernias, account for up to 53% of all internal hernias, but they cause only 0.2–0.9% of all cases of intestinal obstruction. This is the first systematic review of all reported cases so far, investigating their clinical presentation, radiological imaging, and treatment outcomes.MethodsAfter a detailed search in PubMed and Medline, using the keywords “paraduodenal hernia”, 115 studies matched our criteria. A review of these reports was conducted and the full texts were examined.ResultsA total of 159 patients were included in our analysis, with 69.8% and 30.2% of them suffering from either a left or a right PDH, respectively. Mean age at diagnosis was 44.1 years, with a 2/1 male/female ratio. PDH were associated with non-specific symptoms and signs; abdominal pain being the most common. Computed tomography (CT) scan of the abdomen was the most frequently used diagnostic modality. Regardless of PDH localization, all patients were operated on, with approximately one-third of them undergoing a laparoscopic operation, which was associated with a significantly decreased morbidity rate as well as length of hospital stay, compared with the open repair.ConclusionsPDH are not usually associated with specific symptoms and signs; thus, they constitute a diagnostic challenge, requiring a high level of knowledge and clinical suspicion. Undoubtedly, CT scan of the abdomen is the gold standard diagnostic tool. Their operative repair is mandatory, with the laparoscopic approach demonstrating significant advantages over the open repair, seeming to be the optimum treatment strategy.
Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine
PurposeChoice of the best possible fixation system in terms of safety and effectiveness for intraperitoneal mesh placement in hernia surgery remains controversial. The aim of the present study was to compare the performance of four fixation systems in a swine model of intraperitoneal mesh fixation.MethodsFourteen Landrace swine were utilized in the study. The experiment included two stages. Initially, four pieces of mesh (Ventralight ™ ST) sizing 10 × 5 cm were placed and fixed intraperitoneally to reinforce 4 small full thickness abdominal wall defects created with diathermy. These defects were repaired primarily with absorbable suture before mesh implantation. Each mesh was anchored with a different tack device between Absorbatack™, Protack™, Capsure™, or Optifix™. The second stage took place after 60 days and included euthanasia, laparoscopy, and laparotomy via U-shaped incision to obtain the measurements for the outcome parameters. The primary endpoint of the study was to compare the peel strength of the compound tack/mesh from the abdominal wall. Secondary parameters were the extent and quality of visceral adhesions to the mesh, the degree of mesh shrinkage and the histological response around the tacks.ResultsThirteen out of 14 animals survived the experiment and 10 were included in the final analysis. Capsure™ tacks had higher peel strength when compared to Absorbatack™ (p = 0.028); Protack™ (p = 0.043); and Optifix™ (p = 0.009). No significant differences were noted regarding the extent of visceral adhesions (Friedman’s test p value 0.854), the adhesion quality (Friedman’s test p value 0.506), or the mesh shrinkage (Friedman’s test p value = 0.827). Four out of the ten animals developed no adhesions at all 2 months after implantation.ConclusionCapsure™ fixation system provided higher peel strength that the other tested devices in our swine model of intraperitoneal mesh fixation. Our findings generate the hypothesis that this type of fixation may be superior in a clinical setting. Clinical trials with long-term follow-up are required to assess the safety and efficacy of mesh fixation systems in hernia surgery.
Trocar site hernia following laparoscopic cholecystectomy: a 10-year single center experience
Introduction Laparoscopic cholecystectomy (LC) is the gold standard of treatment for patients with symptomatic cholelithiasis. Compared to open cholecystectomy, LC is associated with significantly lower postoperative complications. Trocar site hernia (TSH) is an uncommon, but potentially dangerous, complication of LC. The aim of this study was to evaluate the incidence of TSH following LC. Methods The records of all patients who underwent elective LC between January 2004 and December 2013 were retrospectively reviewed. The open technique with a vertical incision infraumbilically was used to establish pneumoperitoneum. Two or three other skin incisions were made and trocars were inserted. In all cases, only the fascia at the site of infra-umbilical incision was closed. Following hospital discharge, all patients were regularly re-examined 1, 4 and 52 weeks postoperatively and were contacted by phone during November–December 2015. Based on the findings from clinical and telephone follow-ups, the incidence of TSH was recorded. Using univariate/multivariate analysis, we investigated several variables to identify risk factors for TSH development. Results During the study period, 1172 patients were eligible and included in the final analysis. Seven patients (0.6%) presented TSH at 1-year follow-up. At the end of the study and with a mean follow-up of 65.86 ± 25.19 months, 11 patients (0.94%) presented TSH. Interestingly, all TSHs were developed at the infra-umbilical site. Multivariate analysis identified obesity as an independent risk factor for TSH. Conclusion The incidence of TSH following LC is considerably low. Obesity is an independent risk factor for TSH development, while closure of fascial incision of 10 mm below the xiphoid is not justified.
Lichtenstein technique for inguinal hernia repair using polypropylene mesh fixed with sutures vs. self-fixating polypropylene mesh: a prospective randomized comparative study
Purpose Chronic postoperative pain is probably the most significant complication of tension-free inguinal hernia repair as its presence can considerably affect the life quality of the patient. Different mesh materials and different surgical techniques for mesh fixation have been applied to reduce chronic postoperative pain, with controversial, nevertheless, results. The aim of this prospective randomized study was to evaluate the effect of a relatively new mesh with self-fixating properties, used to repair inguinal hernia with the Lichtenstein technique, on early and chronic postoperative pain. Methods Between June 2009 and June 2010, 50 patients with primary unilateral inguinal hernia were treated using the Lichtenstein technique. Patients were randomly assigned to receive either a polypropylene mesh, fixed with polypropylene sutures ( n  = 25; group A), or a self-fixating polypropylene mesh with resorbable polylactic acid microgrips ( n  = 25; group B). Demographic data were recorded. Early and chronic postoperative pain was evaluated using the visual analog scale (VAS). Duration of surgery, complications, length of hospitalization and recurrence were also recorded. Results No statistical difference was found between the two groups in association to demographic data. Operating time was 53.4 ± 12.5 and 44.4 ± 7.2 min in groups A and B, respectively, and the difference was statistically significant ( p  < 0.001). No difference was observed between the groups regarding the postoperative complications. The VAS of early postoperative pain was 1.7 ± 1.9 in group A and 1.3 ± 1.6 in group B, with the difference being not statistically significant ( p  = 0.21). Concerning chronic pain, no remarkable statistically significant difference was observed between the two groups at 3-month, 1- and 2-year follow-up period. At the end of the study, no recurrence was reported in either group. Conclusions Self-fixating mesh can be safely and effectively used in inguinal hernia repair with the additional advantage of reducing the operative time compared to the classic Lichtenstein technique. However, its use is not accompanied by reduced rates in early or chronic postoperative pain.
Tannenbaum and metal stents in the palliative treatment of malignant distal bile duct obstruction: a comparative study of patency and cost effectiveness
Stent clogging is the major limitation of palliative treatment for malignant biliary obstruction. Metal stents have much better patency than plastic stents, but are more expensive. Preliminary data suggest that the recently designed plastic (Tannenbaum) stent has better duration of patency than the polyethylene stent. This study aimed to compare the efficacy and cost effectiveness between the Tannenbaum stent without side holes and the uncovered metal stent for patients with malignant distal common bile duct obstruction. In this study, 47 patients (median age, 73 years, range, 56-86 years) with inoperable malignant distal common bile duct strictures were prospectively randomized to receive either a Tannenbaum stent (n = 24) or an uncovered self-expandable metal stent (n = 23). The patients were clinically evaluated, and biochemical tests were analyzed if necessary until their death or surgery for gastric outlet obstruction. Cumulative first stent patency and patient survival were compared between the two groups. Cost-effectiveness analysis also was performed for the two study groups. The two groups were comparable in terms of age, gender, and diagnosis. The median first stent patency was longer in the metal group than in the Tannenbaum stent group (255 vs 123.5 days; p = 0.002). There was no significant difference in survival between the two groups. The total cost associated with the Tannenbaum stents was lower than for the metal stents (17,700 vs 30,100 euros; p = 0.001), especially for patients with liver metastases (3,000 vs 6,900 euros; p < 0.001). Metal stent placement is an effective treatment for inoperable malignant distal common bile duct obstruction, but Tannenbaum stent placement is a cost-saving strategy, as compared with metal stent placement, especially for patients with liver metastases and expected short survival time.
Endoloop-assisted polypectomy for large pedunculated colorectal polyps
The use of an endoloop may minimize the risk for bleeding after endoscopic polypectomy of large colorectal polyps. This study aimed to assess the safety and efficacy of colonoscopic ligation of the stalk of large pedunculated polyps by means of an endoloop technique, and to focus particular attention on the instances in which the use of this device was unsuccessful. This study retrospectively evaluated attempted endoloop endoscopic polypectomy in 33 patients (19 men and 14 women; mean age, 62.5 years) with large pedunculated polyps. Application of the endoloop was impossible in four patients, and the snare became entangled with the loop in one patient. The remaining 28 patients underwent endoloop-assisted polypectomy. Bleeding occurred in four patients, either because the loop slipped of the stalk after polypectomy (2 patients) or because a thin stalk (< or = 4 mm) was transected by the loop before polypectomy (2 patients). Colonoscopic polypectomy with an endoloop may be safer than conventional polypectomy. The reasons for technical failure of this technique include a narrow left colon lumen, a thin stalk (< or = 4 mm), and close cutting in relation to the site of encirclement by the loop.
Tension-free repair versus modified Bassini technique (Andrews technique) for strangulated inguinal hernia: a comparative study
To compare tension-free hernia repair to a modified Bassini technique (Andrew's technique) used to treat complicated inguinal hernia. In the period 1990-2004, 75 patients were submitted to emergency operation because of strangulated inguinal hernia. 33 patients underwent tension-free repair utilizing a polypropylene mesh (group A), whereas the remaining 42 patients underwent a modified Bassini technique (group B). Mean operative time was significantly longer for group B (91.5+/-9.3 min vs 75.7+/-10.5 min, p<0.05). Postoperative hospital stay was also significantly longer in group B compared to group A (10.3+/-3.4 days vs 4.5+/-2.1 days, p<0.01). Postoperative complication rate did not differ significantly between the two groups (5/33, 15.1% vs 5/42, 11.9%, p=n.s.). No mesh had to be removed. At follow-up (mean 9+/-4.2 years), there was one recurrence in group A (1/33, 3%) and two recurrences in group B (2/42, 4.7%) (p=n.s.). The presence of a strangulated inguinal hernia cannot be considered a contraindication for the use of a prosthetic mesh.
Preoperative Assessment of Perianal Fistulas with Combined Magnetic Resonance and Tridimensional Endoanal Ultrasound: A Prospective Study
Background: we designed a prospective study of diagnostic accuracy that compared pelvic MRI and 3D-EAUS with pelvic MRI alone in the preoperative evaluation and postoperative outcomes of patients with perianal fistulas. Methods: the sample size was 72 patients and this was divided into two imaging groups. MRI alone was performed on the first group. Both MRI and 3D-EAUS were performed in parallel on the second group. Surgical exploration took place after two weeks and was the standard reference. Park’s classification, the presence of a concomitant abscess or a secondary tract, and the location of the internal opening were recorded. All patients were re-evaluated for complete fistula healing and fecal incontinence six months postoperatively. All of the collected data were subjected to statistical analysis. Results: the MRI group included 36 patients with 42 fistulas. The MRI + 3D-EAUS group included 36 patients with 46 fistulas. The adjusted sensitivity and negative predictive value were 1.00 for most fistula types in the group that underwent combined imaging. The adjusted specificity improved for intersphincteric fistulas in the same group. The adjusted balanced accuracy improved for all fistula types except rectovaginal. The combination of imaging methods showed improved diagnostic accuracy only in the detection of a secondary tract. The healing rate at six months was 100%. Fecal incontinence at six months did not present a statistically significant difference between the two groups (Fisher’s exact test p-value > 0.9). Patients with complex perianal fistulas had a statistically significant higher probability of undergoing a second surgery (x2 test p-value = 0.019). Conclusions: the combination of pelvic MRI and 3D-EAUS showed improved metrics of diagnostic accuracy and should be used in the preoperative evaluation of all patients with perianal fistulas, especially those with complex types.