Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
58
result(s) for
"Chubb, Henry"
Sort by:
Weakly supervised classification of aortic valve malformations using unlabeled cardiac MRI sequences
by
Xiao, Ke
,
Chubb, Henry
,
Saha, Priyanka
in
60 APPLIED LIFE SCIENCES
,
631/114/1305
,
692/4019/592/75/1539
2019
Biomedical repositories such as the UK Biobank provide increasing access to prospectively collected cardiac imaging, however these data are unlabeled, which creates barriers to their use in supervised machine learning. We develop a weakly supervised deep learning model for classification of aortic valve malformations using up to 4,000 unlabeled cardiac MRI sequences. Instead of requiring highly curated training data, weak supervision relies on noisy heuristics defined by domain experts to programmatically generate large-scale, imperfect training labels. For aortic valve classification, models trained with imperfect labels substantially outperform a supervised model trained on hand-labeled MRIs. In an orthogonal validation experiment using health outcomes data, our model identifies individuals with a 1.8-fold increase in risk of a major adverse cardiac event. This work formalizes a deep learning baseline for aortic valve classification and outlines a general strategy for using weak supervision to train machine learning models using unlabeled medical images at scale.
The availability of labelled training data is one of the practical obstacles towards wide application of machine learning models in medicine. Here the authors develop a weakly supervised deep learning model for the classification of aortic malformations using unlabelled cardiac MRI sequences from the UK biobank.
Journal Article
Identifying locations of re-entrant drivers from patient-specific distribution of fibrosis in the left atrium
2020
Clinical evidence suggests a link between fibrosis in the left atrium (LA) and atrial fibrillation (AF), the most common sustained arrhythmia. Image-derived fibrosis is increasingly used for patient stratification and therapy guidance. However, locations of re-entrant drivers (RDs) sustaining AF are unknown and therapy success rates remain suboptimal. This study used image-derived LA models to explore the dynamics of RD stabilization in fibrotic regions and generate maps of RD locations. LA models with patient-specific geometry and fibrosis distribution were derived from late gadolinium enhanced magnetic resonance imaging of 6 AF patients. In each model, RDs were initiated at multiple locations, and their trajectories were tracked and overlaid on the LA fibrosis distributions to identify the most likely regions where the RDs stabilized. The simulations showed that the RD dynamics were strongly influenced by the amount and spatial distribution of fibrosis. In patients with fibrosis burden greater than 25%, RDs anchored to specific locations near large fibrotic patches. In patients with fibrosis burden below 25%, RDs either moved near small fibrotic patches or anchored to anatomical features. The patient-specific maps of RD locations showed that areas that harboured the RDs were much smaller than the entire fibrotic areas, indicating potential targets for ablation therapy. Ablating the predicted locations and connecting them to the existing pulmonary vein ablation lesions was the most effective in-silico ablation strategy.
Journal Article
The use of Z-scores in paediatric cardiology
2012
Z-scores are a means of expressing the deviation of a given measurement from the size or age specific population mean. By taking account of growth or age, Z-scores are an excellent means of charting serial measurements in paediatric cardiological practice. They can be applied to echocardiographic measurements, blood pressure and patient growth, and thus may assist in clinical decision-making.
Journal Article
The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
2018
Background
Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation.
Methods
Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters (‘Repro’,
n
= 10), 3 T scanner (‘3 T’, n = 10), half-slice thickness (‘Half-slice’, n = 10) or half GBCA dose (‘Half-gad’, n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence).
Results
A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for ‘Repro’ group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454–0.825, PVE 0.618–0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, ‘Repro’ group). There was no significant relationship between indices of PAAS and AF recurrence.
Conclusion
PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome.
Trial registration
United Kingdom National Research Ethics Service 08/H0802/68 – 30th September 2008.
Journal Article
Optimization of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
2018
Background
Cardiovascular magnetic resonance (CMR) imaging may be used to visualize post-ablation atrial scar (PAAS), and three-dimensional late gadolinium enhancement (3D LGE) is the most widely employed technique for imaging of chronic scar. Detection of PAAS provides a unique non-invasive insight into the effects of the ablation and may help guide further ablation procedures. However, there is evidence that PAAS is often not detected by CMR, implying a significant sensitivity problem, and imaging parameters vary between leading centres. Therefore, there is a need to establish the optimal imaging parameters to detect PAAS.
Methods
Forty subjects undergoing their first pulmonary vein isolation procedure for AF had detailed CMR assessment of atrial scar: one scan pre-ablation, and two scans post-ablation at 3 months (separated by 48 h). Each scan session included ECG- and respiratory-navigated 3D LGE acquisition at 10, 20 and 30 min post injection of a gadolinium-based contrast agent (GBCA). The first post-procedural scan was performed on a 1.5 T scanner with standard acquisition parameters, including double dose (0.2 mmol/kg) Gadovist and 4 mm slice thickness. Ten patients subsequently underwent identical scan as controls, and the other 30 underwent imaging with a reduced, single, dose GBCA (
n
= 10), half slice thickness (
n
= 10) or on a 3 T scanner (
n
= 10). Apparent signal-to-noise (aSNR), contrast-to-noise (aCNR) and imaging quality (Likert Scale, 3 independent observers) were assessed. PAAS location and area (%PAAS scar) were assessed following manual segmentation. Atrial shells with standardised %PAAS at each timepoint were then compared to ablation lesion locations to assess quality of scar delineation.
Results
A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. Likert scale of imaging quality had high interobserver and intraobserver intraclass correlation coefficients (0.89 and 0.96 respectively), and showed lower overall imaging quality on 3 T and at half-slice thickness. aCNR, and quality of scar delineation increased significantly with time. aCNR was higher with reduced, single, dose of GBCA (
p
= 0.005).
Conclusion
3D LGE CMR atrial scar imaging, as assessed qualitatively and quantitatively, improves with time from GBCA administration, with some indices continuing to improve from 20 to 30 min. Imaging should be performed at least 20 min post-GBCA injection, and a single dose of contrast should be considered.
Trial registration
Trial registry- United Kingdom National Research Ethics Service 08/H0802/68 – 30th September 2008.
Journal Article
Utility of smart watches for identifying arrhythmias in children
by
Trela, Anthony
,
Chubb, Henry
,
Navarre, Brittany
in
692/4019/2773
,
692/699/75/29
,
692/700/1720/3187
2023
Background
Arrhythmia symptoms are frequent complaints in children and often require a pediatric cardiology evaluation. Data regarding the clinical utility of wearable technologies are limited in children. We hypothesize that an Apple Watch can capture arrhythmias in children.
Methods
We present an analysis of patients ≤18 years-of-age who had signs of an arrhythmia documented by an Apple Watch. We include patients evaluated at our center over a 4-year-period and highlight those receiving a formal arrhythmia diagnosis. We evaluate the role of the Apple Watch in arrhythmia diagnosis, the results of other ambulatory cardiac monitoring studies, and findings of any EP studies.
Results
We identify 145 electronic-medical-record identifications of
Apple Watch
, and find arrhythmias confirmed in 41 patients (28%) [mean age 13.8 ± 3.2 years]. The arrythmias include: 36 SVT (88%), 3 VT (7%), 1 heart block (2.5%) and wide 1 complex tachycardia (2.5%). We show that invasive EP study confirmed diagnosis in 34 of the 36 patients (94%) with SVT (2 non-inducible). We find that the Apple Watch helped prompt a workup resulting in a new arrhythmia diagnosis for 29 patients (71%). We note traditional ambulatory cardiac monitors were worn by 35 patients (85%), which did not detect arrhythmias in 10 patients (29%). In 73 patients who used an Apple Watch for recreational or self-directed heart rate monitoring, 18 (25%) sought care due to device findings without any arrhythmias identified.
Conclusion
We demonstrate that the Apple Watch can record arrhythmia events in children, including events not identified on traditionally used ambulatory monitors.
Plain language summary
Wearable devices, such as smart watches, have become popular for the monitoring of health, particularly for people with heart conditions. Wearable devices have been well-studied in adults, however there is less information available on their effectiveness in monitoring children’s health. We reviewed the heart electrical recordings of a group of children who submitted recordings obtained from their Apple Watches during moments when they felt as though their heart’s rhythm was abnormal. The Apple Watches captured rhythm abnormalities that matched the diagnoses obtained using heart monitors used clinically. This study shows that use of Apple Watches can enable clinicians to identify abnormalities that many traditional at-home monitoring devices do not detect. Thus, wearable devices, such as the Apple Watch, could be used to help identify heart rhythm disorders in children.
Zahedivash et al. undertake a single center retrospective analysis of patients less than 18 years of age with history of an arrhythmia to determine whether a wearable device can capture arrhythmias. Arrhythmias are identified in 28% of patients, mainly the difficult to identify supraventricular tachycardias.
Journal Article
Single center blind testing of a US multi-center validated diagnostic algorithm for Kawasaki disease in Taiwan
2022
BackgroundKawasaki disease (KD) is the leading cause of acquired heart disease in children. The major challenge in KD diagnosis is that it shares clinical signs with other childhood febrile control (FC) subjects. We sought to determine if our algorithmic approach applied to a Taiwan cohort.MethodsA single center (Chang Gung Memorial Hospital in Taiwan) cohort of patients suspected with acute KD were prospectively enrolled by local KD specialists for KD analysis. Our previously single-center developed computer-based two-step algorithm was further tested by a five-center validation in US. This first blinded multi-center trial validated our approach, with sufficient sensitivity and positive predictive value, to identify most patients with KD diagnosed at centers across the US. This study involved 418 KDs and 259 FCs from the Chang Gung Memorial Hospital in Taiwan.FindingsOur diagnostic algorithm retained sensitivity (379 of 418; 90.7%), specificity (223 of 259; 86.1%), PPV (379 of 409; 92.7%), and NPV (223 of 247; 90.3%) comparable to previous US 2016 single center and US 2020 fiver center results. Only 4.7% (15 of 418) of KD and 2.3% (6 of 259) of FC patients were identified as indeterminate. The algorithm identified 18 of 50 (36%) KD patients who presented 2 or 3 principal criteria. Of 418 KD patients, 157 were infants younger than one year and 89.2% (140 of 157) were classified correctly. Of the 44 patients with KD who had coronary artery abnormalities, our diagnostic algorithm correctly identified 43 (97.7%) including all patients with dilated coronary artery but one who found to resolve in 8 weeks.InterpretationThis work demonstrates the applicability of our algorithmic approach and diagnostic portability in Taiwan.
Journal Article
Improved co-registration of ex-vivo and in-vivo cardiovascular magnetic resonance images using heart-specific flexible 3D printed acrylic scaffold combined with non-rigid registration
2019
Background
Ex-vivo cardiovascular magnetic resonance (CMR) imaging has played an important role in the validation of in-vivo CMR characterization of pathological processes. However, comparison between in-vivo and ex-vivo imaging remains challenging due to shape changes occurring between the two states, which may be non-uniform across the diseased heart. A novel two-step process to facilitate registration between ex-vivo and in-vivo CMR was developed and evaluated in a porcine model of chronic myocardial infarction (MI).
Methods
Seven weeks after ischemia-reperfusion MI, 12 swine underwent in-vivo CMR imaging with late gadolinium enhancement followed by ex-vivo CMR 1 week later. Five animals comprised the control group, in which ex-vivo imaging was undertaken without any support in the LV cavity, 7 animals comprised the experimental group, in which a two-step registration optimization process was undertaken. The first step involved a heart specific flexible 3D printed scaffold generated from in-vivo CMR, which was used to maintain left ventricular (LV) shape during ex-vivo imaging. In the second step, a non-rigid co-registration algorithm was applied to align in-vivo and ex-vivo data. Tissue dimension changes between in-vivo and ex-vivo imaging were compared between the experimental and control group. In the experimental group, tissue compartment volumes and thickness were compared between in-vivo and ex-vivo data before and after non-rigid registration. The effectiveness of the alignment was assessed quantitatively using the DICE similarity coefficient.
Results
LV cavity volume changed more in the control group (ratio of cavity volume between ex-vivo and in-vivo imaging in control and experimental group 0.14 vs 0.56,
p
< 0.0001) and there was a significantly greater change in the short axis dimensions in the control group (ratio of short axis dimensions in control and experimental group 0.38 vs 0.79,
p
< 0.001). In the experimental group, prior to non-rigid co-registration the LV cavity contracted isotropically in the ex-vivo condition by less than 20% in each dimension. There was a significant proportional change in tissue thickness in the healthy myocardium (change = 29 ± 21%), but not in dense scar (change = − 2 ± 2%,
p
= 0.034). Following the non-rigid co-registration step of the process, the DICE similarity coefficients for the myocardium, LV cavity and scar were 0.93 (±0.02), 0.89 (±0.01) and 0.77 (±0.07) respectively and the myocardial tissue and LV cavity volumes had a ratio of 1.03 and 1.00 respectively.
Conclusions
The pattern of the morphological changes seen between the in-vivo and the ex-vivo LV differs between scar and healthy myocardium. A 3D printed flexible scaffold based on the in-vivo shape of the LV cavity is an effective strategy to minimize morphological changes in the ex-vivo LV. The subsequent non-rigid registration step further improved the co-registration and local comparison between in-vivo and ex-vivo data.
Journal Article
Pacing and Defibrillators in Complex Congenital Heart Disease
by
Chubb, Henry
,
O’Neill, Mark
,
Rosenthal, Eric
in
Cardiovascular disease
,
Catheters
,
Congenital diseases
2016
Device therapy in the complex congenital heart disease (CHD) population is a challenging field. There is a myriad of devices available, but none designed specifically for the CHD patient group, and a scarcity of prospective studies to guide best practice. Baseline cardiac anatomy, prior surgical and interventional procedures, existing tachyarrhythmias and the requirement for future intervention all play a substantial role in decision making. For both pacing systems and implantable cardioverter defibrillators, numerous factors impact on the merits of system location (endovascular versus non-endovascular), lead positioning, device selection and device programming. For those with Fontan circulation and following the atrial switch procedure there are also very specific considerations regarding access and potential complications. This review discusses the published guidelines, device indications and the best available evidence for guidance of device implantation in the complex CHD population.
Journal Article
AI learning for pediatric right ventricular assessment: development and validation across multiple centers
2025
Congenital and acquired heart disease affects approximately 1% of children worldwide, and right ventricular (RV) dysfunction is a common and complex manifestation in conditions such as congenital heart disease, pulmonary hypertension, and prematurity. Accurate RV assessment remains difficult due to the ventricle’s irregular geometry and morphological variability in pediatric patients. Using 24,984 echocardiograms from 3993 children across four tertiary centers in North America and Asia, we developed and validated a video-based deep learning framework for automated RV functional assessment. The model performs frame-level ventricular segmentation and beat-by-beat estimation of fractional area change (FAC), classification of RV-related disease, and exploratory prediction of left ventricular ejection fraction (LV EF). A U²-Net architecture achieved high segmentation accuracy (Dice = 0.86 [A4C], 0.88 [PSAX]) and classification performance (AUC = 0.95 U.S., 0.97 Asia). In LV EF prediction, the model outperformed previous methods across cohorts. This validated framework enables expert-level, real-time quantification of pediatric ventricular function, enhancing diagnostic consistency, reducing manual workload, and supporting earlier intervention for children with heart disease, particularly in resource-limited settings.
Journal Article