Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "Dungan, Kathleenbn M."
Sort by:
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Clinical trial data demonstrates improved glycemic control with hybrid close loop (HCL) insulin delivery systems, yet limited real-world data exists. Data from the inaugural cohort of patients initiating a HCL system (Medtronic MiniMed 670G, Medtronic Canada, Brampton, ON) at a university medical center was used to examine real-world utilization and glycemic control following a standardized implementation process. Data from 34 adult patients with type 1 diabetes were obtained from pump downloads at 4 time points: ( ) previous insulin pump, ( ) HCL in manual-mode, ( ) 2 weeks after HCL auto-mode transition, and ( ) 6 to 12 weeks after initiation of HCL. In-person training by certified diabetes educators was performed across 3 sessions with phone and electronic messaging following auto-mode start. Mean self-monitored blood glucose (SMBG) per day increased from 5.15 baseline to 6.49 at 6 to 12 weeks ( <.05) with 3.26 sensor calibrations per day. Time-in-auto-mode was 79.3% at 2 weeks and 72.3% at final follow-up, with 82% of patients spending >50% of time in auto-mode. There were 8.2 auto-mode exits over the final 14-day download. Time-in-target was 67.3% in manual-mode, 73.4% at 2 weeks ( = .09), and 71.7% by 6 to 12 weeks ( = .06). Hemoglobin A1c (HbA1c) decreased by 0.51% ( = .02), while total daily dose and % basal did not change. Patients with HbA1c <7.0% (53 mmol/mol) at baseline spent more time-in-target than those with HbA1c ≥7.0% (53 mmol/mol; 78.0% versus 67.5%) despite spending less time-in-auto-mode (66.5% versus 74.8%). These data illustrate real-world implementation of HCL technology using a structured education program within a major medical center. Overall benefit may vary based on baseline characteristics such as HbA1c. = certified diabetes educator; = hemoglobin A1c; = hybrid closed loop; = self-monitored blood glucose.