Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Reading LevelReading Level
-
Content TypeContent Type
-
YearFrom:-To:
-
More FiltersMore FiltersItem TypeIs Full-Text AvailableSubjectCountry Of PublicationPublisherSourceTarget AudienceDonorLanguagePlace of PublicationContributorsLocation
Done
Filters
Reset
352
result(s) for
"Hamilton, Ruth"
Sort by:
That Liverpool girl
by
Hamilton, Ruth author
in
World War, 1939-1945 England Liverpool Fiction
,
Tragedy Fiction
,
Romance fiction
2011
Three generations of strong, determined women and the war that threatened to tear them apart. In the backstreets of Liverpool, Eileen Watson lives with her mother, Nellie, daughter Mel and her three tear-away sons. Life isn't great, but they have eachother, and family can get you through anything. Or... can it? Then, on the third day in September 1939, Britain declares war on Germany and their lives change forever.
ISCEV Standard for full-field clinical electroretinography (2022 update)
2022
The full-field electroretinogram (ERG) is a mass electrophysiological response to diffuse flashes of light and is used widely to assess generalized retinal function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for clinical ERG testing. Minimum protocols for basic ERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis, monitoring and inter-laboratory comparisons, while also responding to evolving clinical practices and technology. The main changes in this updated ISCEV Standard for clinical ERGs include specifying that ERGs may meet the Standard without mydriasis, providing stimuli adequately compensate for non-dilated pupils. There is more detail about analysis of dark-adapted oscillatory potentials (OPs) and the document format has been updated and supplementary content reduced. There is a more detailed review of the origins of the major ERG components. Several tests previously tabulated as additional ERG protocols are now cited as published ISCEV extended protocols. A non-standard abbreviated ERG protocol is described, for use when patient age, compliance or other circumstances preclude ISCEV Standard ERG testing.
Journal Article
ISCEV Standard for full-field clinical electroretinography (2015 update)
by
Hamilton, Ruth
,
Brigell, Mitchell G.
,
Bach, Michael
in
Accommodation, Ocular - physiology
,
Dark Adaptation - physiology
,
Electrodes
2015
This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for full-field clinical electroretinography (ffERG or simply ERG). The parameters for Standard flash stimuli have been revised to accommodate a variety of light sources including gas discharge lamps and light emitting diodes. This ISCEV Standard for clinical ERGs specifies six responses based on the adaptation state of the eye and the flash strength: (1) Dark-adapted 0.01 ERG (rod ERG); (2) Dark-adapted 3 ERG (combined rod-cone standard flash ERG); (3) Dark-adapted 3 oscillatory potentials; (4) Dark-adapted 10 ERG (strong flash ERG); (5) Light-adapted 3 ERG (standard flash “cone” ERG); and (6) Light-adapted 30 Hz flicker ERG. ISCEV encourages the use of additional ERG protocols for testing beyond this minimum standard for clinical ERGs.
Journal Article
Reference ranges for clinical electrophysiology of vision
2021
IntroductionEstablishing robust reference intervals for clinical procedures has received much attention from international clinical laboratories, with approved guidelines. Physiological measurement laboratories have given this topic less attention; however, most of the principles are transferable.MethodsHerein, we summarise those principles and expand them to cover bilateral measurements and one-tailed reference intervals, which are common issues for those interpreting clinical visual electrophysiology tests such as electroretinograms (ERGs), visual evoked potentials (VEPs) and electrooculograms (EOGs).ResultsThe gold standard process of establishing and defining reference intervals, which are adequately reliable, entails collecting data from a minimum of 120 suitable reference individuals for each partition (e.g. sex, age) and defining limits with nonparametric methods. Parametric techniques may be used under some conditions. A brief outline of methods for defining reference limits from patient data (indirect sampling) is given. Reference intervals established elsewhere, or with older protocols, can be transferred or verified with as few as 40 and 20 suitable reference individuals, respectively. Consideration is given to small numbers of reference subjects, interpretation of serial measurements using subject-based reference values, multidimensional reference regions and age-dependent reference values. Bilateral measurements, despite their correlation, can be used to improve reference intervals although additional care is required in computing the confidence in the reference interval or the reference interval itself when bilateral measurements are only available from some of subjects.DiscussionGood quality reference limits minimise false-positive and false-negative results, thereby maximising the clinical utility and patient benefit. Quality indicators include using appropriately sized reference datasets with appropriate numerical handling for reporting; using subject-based reference limits where appropriate; and limiting tests for each patient to only those which are clinically indicated, independent and highly discriminating.
Journal Article
VEP estimation of visual acuity: a systematic review
by
Thompson, Dorothy A
,
Hamilton, Ruth
,
McCulloch, Daphne L
in
Acuity
,
Children
,
Frequency dependence
2021
PurposeVisual evoked potentials (VEPs) can be used to measure visual resolution via a spatial frequency (SF) limit as an objective estimate of visual acuity. The aim of this systematic review is to collate descriptions of the VEP SF limit in humans, healthy and disordered, and to assess how accurately and precisely VEP SF limits reflect visual acuity.MethodsThe protocol methodology followed the PRISMA statement. Multiple databases were searched using “VEP” and “acuity” and associated terms, plus hand search: titles, abstracts or full text were reviewed for eligibility. Data extracted included VEP SF limits, stimulus protocols, VEP recording and analysis techniques and correspondence with behavioural acuity for normally sighted healthy adults, typically developing infants and children, healthy adults with artificially degraded vision and patients with ophthalmic or neurological conditions.ResultsA total of 155 studies are included. Commonly used stimulus, recording and analysis techniques are summarised. Average healthy adult VEP SF limits vary from 15 to 40 cpd, depend on stimulus, recording and analysis techniques and are often, but not always, poorer than behavioural acuity measured either psychophysically with an identical stimulus or with a clinical acuity test. The difference between VEP SF limit and behavioural acuity is variable and strongly dependent on the VEP stimulus and choice of acuity test. VEP SF limits mature rapidly, from 1.5 to 9 cpd by the end of the first month of life to 12–20 cpd by 8–12 months, with slower improvement to 20–40 cpd by 3–5 years. VEP SF limits are much better than behavioural thresholds in the youngest, typically developing infants. This difference lessens with age and reaches equivalence between 1 and 2 years; from around 3–5 years, behavioural acuity is better than the VEP SF limit, as for adults. Healthy, artificially blurred adults had slightly better behavioural acuity than VEP SF limits across a wide range of acuities, while adults with heterogeneous ophthalmic or neurological pathologies causing reduced acuity showed a much wider and less consistent relationship. For refractive error, ocular media opacity or pathology primarily affecting the retina, VEP SF limits and behavioural acuity had a fairly consistent relationship across a wide range of acuity. This relationship was much less consistent or close for primarily macular, optic nerve or neurological conditions such as amblyopia. VEP SF limits were almost always normal in patients with non-organic visual acuity loss.ConclusionsThe VEP SF limit has great utility as an objective acuity estimator, especially in pre-verbal children or patients of any age with motor or learning impairments which prevent reliable measurement of behavioural acuity. Its diagnostic power depends heavily on adequate, age-stratified, reference data, age-stratified empirical calibration with behavioural acuity, and interpretation in the light of other electrophysiological and clinical findings. Future developments could encompass faster, more objective and robust techniques such as real-time, adaptive control.Registration International prospective register of systematic reviews PROSPERO (https://www.crd.york.ac.uk/PROSPERO/), registration number CRD42018085666.
Journal Article
Beyond the clipboard: data collection with GridScore NEXT
2026
Background
Accurate acquisition of phenotypic data is critical for cataloguing and utilising genetic variation in cultivated crops, landraces, and their wild relatives. The collection of phenotypic data using handwritten notes often introduces errors which can and should be avoided. Electronic data collection is crucial for ensuring error prevention and data standardisation and thus ensuring high-quality, reliable data.
Implementation
This paper describes the development of GridScore NEXT, a new plant phenotyping application that significantly advances the state of the art for collecting field trial data in plant genetics, pre-breeding and crop improvement research. Building on its predecessor, GridScore, the development of GridScore NEXT was driven by real life, in the field interactions with expert user groups across a number of crops. This iterative design methodology allowed the development and testing of new features. Collaborators from the 'Biodiversity for Opportunities, Livelihoods and Development' (BOLD) project, focusing on crops including rice, grasspea, and alfalfa, along with barley, potato, vegetable and blueberry teams, provided invaluable insights through training sessions and interviews and in the field use of the application.
Results
Key improvements to GridScore NEXT include enhanced data collection tools, supporting individual plant phenotyping within plots and enabling new data types such as GPS coordinates and image traits. GridScore NEXT provides customisable user defined validation rules to help prevent errors and incorporates barcode scanning for accurate, efficient data capture. The application offers an increased toolbox of data visualizations over its predecessor including heatmaps and statistical box plots, which aid in identifying potential data issues and understanding trial performance in the field. GridScore NEXT is cross-platform and can operate without an internet connection, making it ideal for field use in remote areas. Its adoption has led to standardisation of methods, significant error reduction, and the timely sharing of data, enabling quicker decision-making in pre-breeding and characterisation experiments. GridScore NEXT is available under an open-source (Apache 2.0) licence and freely available to all with no restrictions. It offers self-hosting options for enhanced data security and privacy. GridScore NEXT shows broad applicability across a diverse range of not only plant phenotyping experiments, but any experiment that requires the collection of accurate data.
Journal Article
ISCEV extended protocol for VEP methods of estimation of visual acuity
by
Thompson, Dorothy A
,
Hamilton, Ruth
,
McCulloch, Daphne L
in
Acuity
,
Electrophysiology
,
Frequency dependence
2021
The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for visual evoked potentials (VEPs) describes a minimum procedure for clinical VEP testing and encourages more extensive testing. This ISCEV extended protocol is an extension to the VEP standard. It describes procedures for recording multiple VEPs to a range of sizes of pattern stimuli to establish the VEP spatial frequency limit (threshold) and for relating this limit to visual acuity.
Journal Article
ISCEV extended protocol for the dark-adapted red flash ERG
by
Robson, Anthony G
,
Thompson, Dorothy A
,
Hamilton, Ruth
in
Children
,
Color blindness
,
Dystrophy
2018
The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for full-field electroretinography (ERG) describes a minimum procedure, but encourages more extensive testing. This ISCEV extended protocol describes an extension to the ERG standard, namely the dark-adapted (DA) red flash ERG. The DA red flash ERG can be incorporated conveniently within the ISCEV standard ERG protocol after a minimum of 20-min DA and recorded after the DA 0.01 ERG to a flash strength of 0.3 phot cd s m−2, eliciting a waveform with two positive peaks in healthy individuals. The first positive component is the cone-mediated x-wave with a peak at 30–50 ms; the second is a rod-mediated b-wave with a peak time of approximately 100 ms. Shorter DA times may be desirable to shorten the recording time or to alter the prominence of the early cone-mediated x-wave relative to the rod-mediated b-wave. The DA red flash ERG is used to aid the diagnosis of achromatopsia (rod monochromacy), cone dystrophy and other forms of cone system dysfunction, including “Bradyopsia” (RGS9/R9AP-retinopathy), when the DA red flash ERG x-wave is preserved in the absence of ISCEV standard LA ERGs. The DA red flash ERG can also help determine the origin of residual DA ERGs in cases of severe rod dysfunction, for example in disorders such as vitamin A deficiency, fundus albipunctatus (RDH5-retinopathy), Oguchi disease (SAG- or GRK1-retinopathy) and some rod-cone dystrophies. To shorter DA periods, the x-wave may be elicited without the following rod b-wave, shown to be helpful in abbreviated protocols for children.
Journal Article
ISCEV extended protocol for the stimulus–response series for light-adapted full-field ERG
by
Lachapelle, Pierre
,
Hamilton, Ruth
,
McCulloch, Daphne L
in
Bipolar cells
,
Cones
,
Electrophysiology
2019
The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for full-field electroretinography (ERG) describes a minimum protocol for clinical testing but encourages additional ERG testing when appropriate. This ISCEV extended protocol describes methods to record and evaluate a light-adapted (LA) ERG stimulus–response series with increasing flash strengths. The LA ERG stimulus–response series (also referred to as the luminance–response or intensity–response series in the published literature) can characterise generalised cone system function more comprehensively than the ISCEV standard LA ERGs alone. The amplitude of LA ERG a-waves, arising from cones and cone off-bipolar cells, typically shows a saturating function. The LA ERG b-wave amplitudes, which arise primarily from activity of retinal bipolar cells, show an amplitude peak followed by a nonzero plateau (the “photopic hill” phenomenon). This ISCEV extended protocol specifies a stimulus–response series suitable to evaluate generalised dysfunction affecting the LA retina, to aid in distinguishing between the on- and off-responses of the cone system and to monitor ERG changes in these characteristics. The LA ERG stimulus–response series for a- and b-waves is recorded to a sequence of nine flash stimuli ranging from 0.03 to 300 cd s m−2, superimposed on a standard background of 30 cd m−2. A shorter protocol is also presented to measure the mid-range of the function (the “photopic hill”) using 5 flash stimuli.
Journal Article