Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Reference ranges for clinical electrophysiology of vision
by
Hamilton, Ruth
, Quentin, Davis C
in
Age
/ Electrophysiology
/ Electroretinograms
/ Laboratories
/ Patients
/ Visual evoked potentials
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Reference ranges for clinical electrophysiology of vision
by
Hamilton, Ruth
, Quentin, Davis C
in
Age
/ Electrophysiology
/ Electroretinograms
/ Laboratories
/ Patients
/ Visual evoked potentials
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Reference ranges for clinical electrophysiology of vision
2021
Request Book From Autostore
and Choose the Collection Method
Overview
IntroductionEstablishing robust reference intervals for clinical procedures has received much attention from international clinical laboratories, with approved guidelines. Physiological measurement laboratories have given this topic less attention; however, most of the principles are transferable.MethodsHerein, we summarise those principles and expand them to cover bilateral measurements and one-tailed reference intervals, which are common issues for those interpreting clinical visual electrophysiology tests such as electroretinograms (ERGs), visual evoked potentials (VEPs) and electrooculograms (EOGs).ResultsThe gold standard process of establishing and defining reference intervals, which are adequately reliable, entails collecting data from a minimum of 120 suitable reference individuals for each partition (e.g. sex, age) and defining limits with nonparametric methods. Parametric techniques may be used under some conditions. A brief outline of methods for defining reference limits from patient data (indirect sampling) is given. Reference intervals established elsewhere, or with older protocols, can be transferred or verified with as few as 40 and 20 suitable reference individuals, respectively. Consideration is given to small numbers of reference subjects, interpretation of serial measurements using subject-based reference values, multidimensional reference regions and age-dependent reference values. Bilateral measurements, despite their correlation, can be used to improve reference intervals although additional care is required in computing the confidence in the reference interval or the reference interval itself when bilateral measurements are only available from some of subjects.DiscussionGood quality reference limits minimise false-positive and false-negative results, thereby maximising the clinical utility and patient benefit. Quality indicators include using appropriately sized reference datasets with appropriate numerical handling for reporting; using subject-based reference limits where appropriate; and limiting tests for each patient to only those which are clinically indicated, independent and highly discriminating.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.