Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
59
result(s) for
"Henzlova, Milena J."
Sort by:
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
by
Baber, Usman
,
Sweeny, Joseph M.
,
Guma, Krista A.
in
Aged
,
Area Under Curve
,
automated quantification
2013
Recently introduced high-efficiency (HE) SPECT cameras with solid-state CZT detectors have been shown to decrease imaging time and reduce radiation exposure to patients. An automated, computer-derived quantification of HE MPI has been shown to correlate well with coronary angiography on one HE SPECT camera system (D-SPECT), but has not been compared to visual interpretation on any of the HE SPECT platforms.
Patients undergoing a clinically indicated Tc-99m sestamibi HE SPECT (GE Discovery 530c with supine and prone imaging) study over a 1-year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Both MPI studies and coronary angiograms were reinterpreted by blinded readers. One hundred and twenty two very low (risk of CAD < 5%) or low (risk of CAD < 10%) likelihood subjects with normal myocardial perfusion were used to create normal reference limits. Computer-derived quantification of the total perfusion deficit at stress and rest was obtained with QPS software. The visual and automated MPI quantification were compared to coronary angiography (≥70% luminal stenosis) by receiver operating curve (ROC) analysis.
Of the 3,111 patients who underwent HE SPECT over a 1-year period, 160 patients qualified for the correlation study (66% male, 52% with a history of CAD). The ROC area under the curve (AUC) was similar for both the automated and the visual interpretations using both supine only and combined supine and prone images (0.69-0.74). Using thresholds determined from sensitivity and specificity curves, the automated reads showed higher specificity (59%-67% vs 27%-60%) and lower sensitivity (71%-72% vs 79%-93%) than the visual reads. By including prone images sensitivity decreased slightly but specificity increased for both. By excluding patients with known CAD and cardiomyopathies, AUC and specificity increased for both techniques (0.72-0.82). The use of a difference score to evaluate ischemic burden resulted in lower sensitivities but higher specificities for both automated and visual quantification. There was good agreement between the visual interpretation and automated quantification in the entire cohort of 160 unselected consecutive patients (r = 0.70-0.81, P < .0001).
Automated and visual quantification of high-efficiency SPECT MPI with the GE Discovery camera provides similar overall diagnostic accuracy when compared to coronary angiography. There was good correlation between the two methods of assessment. Combined supine and prone stress imaging provided the best diagnostic accuracy.
Journal Article
Comparison of high efficiency CZT SPECT MPI to coronary angiography
2011
The recently introduced cadmium zinc telluride (CZT) SPECT cameras have the potential to reduce radiation exposure to patients and shorten imaging time. So far, there has been only one small study comparing the results of high efficiency CZT SPECT myocardial perfusion imaging (MPI) to invasive coronary angiography.
All patients who had either a Tc-99m sestamibi or Tl-201 SPECT MPI study using a CZT camera (GE Discovery NM 530c) over a 1-year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Standard stress protocols were employed. Rest images were acquired for 5 min and stress supine and prone images for 3 min each. Both MPI studies and coronary angiograms were interpreted by blinded readers. A standard 17-segment model was employed for MPI interpretation, and coronary angiograms were interpreted for the presence of obstructive epicardial coronary artery disease (CAD) defined as ≥70% luminal narrowing. Correlation was based on the ability to diagnose obstructive epicardial CAD.
Of the 3,111 patients who underwent SPECT imaging using the CZT camera during this time period, 230 patients qualified for the correlation study (mean age 64.2 ± 11.0 years old, 69% male, and 49% had a history of intracoronary stenting). Tc-99m was used in 76% vs Tl-201 in 24% of the studies. Exercise stress was performed in 60% of patients and vasodilator pharmacologic stress in 40%. Sensitivity was 95%, normalcy rate was 97%, and accuracy was 69% for detecting obstructive CAD.
In this so far largest correlation study between coronary angiography and high efficiency CZT SPECT imaging, a high sensitivity and accuracy for detecting obstructive epicardial CAD was found for this new SPECT camera technology.
Journal Article
Aminophylline shortage and current recommendations for reversal of vasodilator stress: an ASNC information statement endorsed by SCMR
by
Schwartz, Ronald G.
,
Dyke, Christopher
,
Abidov, Aiden
in
Aminophylline
,
Aminophylline - administration & dosage
,
Aminophylline - supply & distribution
2018
Pharmacologic reversal of serious or intolerable side effects (SISE) from vasodilator stress is an important safety and comfort measure for patients experiencing such effects. While typically performed using intravenous aminophylline, recurrent shortages of this agent have led to a greater need to limit its use and consider alternative agents. This information statement provides background and recommendations addressing indications for vasodilator reversal, timing of a reversal agent, incidence of observed SISE with vasodilator stress, clinical and logistical considerations for aminophylline-based reversal, and alternative non-aminophylline based reversal protocols.
Journal Article
SPECT myocardial perfusion imaging in liver transplantation candidates
by
Singhvi, Aditi
,
W Lane Duvall
,
Tripathi, Nidhi
in
Ejection fraction
,
Liver
,
Liver transplants
2020
BackgroundThe optimal cardiovascular evaluation prior to liver transplantation remains controversial and includes stress echocardiography, stress MPI, cardiac CTA, and coronary angiography. This study summarizes our experience of the past decade using SPECT MPI in patients with end-stage liver disease, including patient characteristics, stress testing protocols, test results, the need for repeat testing, and downstream testing.MethodsAll patients who underwent a clinically indicated stress SPECT MPI study as part of their pre-liver transplant evaluation from 2004 to 2014 were reviewed from the Nuclear Cardiology database. Results of perfusion imaging, repeat testing, subsequent angiography, and need for revascularization were reviewed.ResultsA total of 2500 patients were referred for SPECT MPI, of those 111 had known CAD and 271 underwent more than one MPI study. Compared to other patients undergoing stress MPI, pre-liver transplant patients were younger, had fewer cardiac risk factors and lower prevalence of prior cardiac history, and used pharmacologic stress more often. During the study decade, patient age increased, prevalence of hypertension increased and smoking decreased, prevalence of known CAD increased, and the number of abnormal studies decreased. Abnormal perfusion results were present in 7.8% of pre-liver transplant patients compared to 34.3% of all other patients. In a multivariate model, age and lower ejection fraction were associated with an abnormal MPI result. Of the 64 patients who underwent subsequent invasive or non-invasive coronary angiography after an abnormal MPI, obstructive CAD was diagnosed in 25 patients (1.0%), non-obstructive CAD was diagnosed in 23 patients (0.9%), and normal coronaries found in 16 patients (0.6%); a total of 18 (0.7%) of these underwent coronary revascularization. The average time to repeat testing was 27.2 ± 17.9 months. In a multivariate model, younger age and exercise stress were associated with repeat testing. In only 17 patients out of 271 with a normal initial perfusion, the repeat study became abnormal. The use of stress-first imaging was successful in 80% of patients with a reduction in Tc-99m dose from 39.1 to 18.3 mCi.ConclusionAbnormal SPECT MPI results in candidates for liver transplantation are infrequent compared to non-liver transplant patients and the incidence of obstructive CAD on subsequent angiography even less. Repeat testing in those on the transplant waiting list after initial normal test results appears to be of limited value. Stress-first protocols may be considered for the majority of these patients to reduce testing time and radiation exposure.
Journal Article
Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera
2011
In light of recent focus on diagnostic imaging, cardiac SPECT imaging needs to become a shorter test with lower radiation exposure to patients. Recently introduced Cadmium Zinc Telluride (CZT) cameras have the potential to achieve both goals.
During a 2-month period patients presenting for a Tc-99m sestamibi SPECT MPI study were imaged using a CZT camera using a low-dose rest-stress protocol (5 mCi rest and 15 mCi stress doses). Patients ≥250 lbs or a BMI ≥35 kg/m2 were excluded. Rest images were processed at 5- and 8-minute acquisition times and stress images at 3- and 5-minute acquisition times. A subset of patients had stress imaging performed using both conventional and CZT SPECT cameras. Image acquisition times and SPECT camera images were compared based on total counts, count rate, image quality, and summed rest and stress scores. Twelve month clinical follow-up was also obtained.
131 patients underwent the study protocol (age 64.9 ± 9.8 years, 54.2% male). There was no significant difference in image quality and mean summed scores between 5- and 8-minute rest images and between 3- and 5-minute stress images. When compared to a conventional SPECT camera in 27 patients, total rest and stress perfusion deficits and calculated LVEF were similar (r = 0.94 and 0.96, respectively). At 12 months there was a benign prognosis in patients with normal perfusion. The effective dose was 5.8 mSv for this protocol which is 49.2% less than conventional Tc-99m studies and 75.7% less than conventional Tl-201/Tc-99m dual isotope studies.
New SPECT camera technology with low isotope dose significantly reduces ionizing radiation exposure and imaging times compared to traditional protocols while maintaining image quality and diagnostic accuracy.
Journal Article
A multi-center assessment of the temporal trends in myocardial perfusion imaging
2015
Recent literature suggests that the frequency of abnormal SPECT myocardial perfusion imaging (MPI) has decreased over the past two decades despite an increase in the prevalence of many cardiac risk factors. This study examined the trends in the prevalence of obstructive coronary artery disease (CAD) by abnormal and ischemic MPI and invasive angiography.
We analyzed all patients who underwent stress MPI or invasive angiography at two academic centers between January 1996 and December 2012, for their demographic data and study results.
A total of 108,654 MPI studies were performed. Over time, the percentage of patients with hypertension, hyperlipidemia, diabetes, and a history of smoking increased. There was a decline in the prevalence of abnormal MPI studies in all patients as well as in those with and without known CAD (from 47.2%, 71.8%, and 31.4% in 1996 to 33.9%, 64.8%, and 18.8% in 2012, respectively, all P < .0001). Similarly, there was a decline in the prevalence of ischemic MPI studies in all patients as well as in those with and without known CAD. A total of 142,924 invasive angiograms were performed. There was a decline in the prevalence of one-vessel and multi-vessel coronary disease (from 29.1% and 53.6% in 1996 to 22.4% and 35.9% in 2012, respectively, all P < .0001).
There has been a temporal decline in the prevalence of abnormal and ischemic MPI studies as well as the frequency and extent of obstructive CAD on angiography. However, this decline was not to the same extent as previously reported, and the overall 34% abnormal MPI rate, with 19% in patients with no known CAD and 65% in patients with known CAD, remains a clinically relevant percentage of patients tested.
Journal Article