Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
by
Baber, Usman
, Sweeny, Joseph M.
, Guma, Krista A.
, George, Titus
, Slomka, Piotr J.
, Croft, Lori B.
, Duvall, W. Lane
, Gerlach, Jim R.
, Henzlova, Milena J.
in
Aged
/ Area Under Curve
/ automated quantification
/ Automation
/ Cardiology
/ Cohort Studies
/ Constriction, Pathologic - pathology
/ Coronary Angiography
/ Coronary Artery Bypass
/ Coronary Artery Disease - diagnostic imaging
/ Coronary Artery Disease - therapy
/ CZT SPECT MPI
/ Exercise Test
/ Female
/ high-efficiency SPECT MPI
/ Humans
/ Image Processing, Computer-Assisted
/ Imaging
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Myocardial Perfusion Imaging
/ Nuclear Medicine
/ Original Article
/ Radiology
/ Radiopharmaceuticals
/ Reference Values
/ Reproducibility of Results
/ Retrospective Studies
/ ROC Curve
/ Sensitivity and Specificity
/ Software
/ Technetium Tc 99m Sestamibi
/ Time Factors
/ Tomography, Emission-Computed, Single-Photon
2013
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
by
Baber, Usman
, Sweeny, Joseph M.
, Guma, Krista A.
, George, Titus
, Slomka, Piotr J.
, Croft, Lori B.
, Duvall, W. Lane
, Gerlach, Jim R.
, Henzlova, Milena J.
in
Aged
/ Area Under Curve
/ automated quantification
/ Automation
/ Cardiology
/ Cohort Studies
/ Constriction, Pathologic - pathology
/ Coronary Angiography
/ Coronary Artery Bypass
/ Coronary Artery Disease - diagnostic imaging
/ Coronary Artery Disease - therapy
/ CZT SPECT MPI
/ Exercise Test
/ Female
/ high-efficiency SPECT MPI
/ Humans
/ Image Processing, Computer-Assisted
/ Imaging
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Myocardial Perfusion Imaging
/ Nuclear Medicine
/ Original Article
/ Radiology
/ Radiopharmaceuticals
/ Reference Values
/ Reproducibility of Results
/ Retrospective Studies
/ ROC Curve
/ Sensitivity and Specificity
/ Software
/ Technetium Tc 99m Sestamibi
/ Time Factors
/ Tomography, Emission-Computed, Single-Photon
2013
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
by
Baber, Usman
, Sweeny, Joseph M.
, Guma, Krista A.
, George, Titus
, Slomka, Piotr J.
, Croft, Lori B.
, Duvall, W. Lane
, Gerlach, Jim R.
, Henzlova, Milena J.
in
Aged
/ Area Under Curve
/ automated quantification
/ Automation
/ Cardiology
/ Cohort Studies
/ Constriction, Pathologic - pathology
/ Coronary Angiography
/ Coronary Artery Bypass
/ Coronary Artery Disease - diagnostic imaging
/ Coronary Artery Disease - therapy
/ CZT SPECT MPI
/ Exercise Test
/ Female
/ high-efficiency SPECT MPI
/ Humans
/ Image Processing, Computer-Assisted
/ Imaging
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Myocardial Perfusion Imaging
/ Nuclear Medicine
/ Original Article
/ Radiology
/ Radiopharmaceuticals
/ Reference Values
/ Reproducibility of Results
/ Retrospective Studies
/ ROC Curve
/ Sensitivity and Specificity
/ Software
/ Technetium Tc 99m Sestamibi
/ Time Factors
/ Tomography, Emission-Computed, Single-Photon
2013
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
Journal Article
High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography
2013
Request Book From Autostore
and Choose the Collection Method
Overview
Recently introduced high-efficiency (HE) SPECT cameras with solid-state CZT detectors have been shown to decrease imaging time and reduce radiation exposure to patients. An automated, computer-derived quantification of HE MPI has been shown to correlate well with coronary angiography on one HE SPECT camera system (D-SPECT), but has not been compared to visual interpretation on any of the HE SPECT platforms.
Patients undergoing a clinically indicated Tc-99m sestamibi HE SPECT (GE Discovery 530c with supine and prone imaging) study over a 1-year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Both MPI studies and coronary angiograms were reinterpreted by blinded readers. One hundred and twenty two very low (risk of CAD < 5%) or low (risk of CAD < 10%) likelihood subjects with normal myocardial perfusion were used to create normal reference limits. Computer-derived quantification of the total perfusion deficit at stress and rest was obtained with QPS software. The visual and automated MPI quantification were compared to coronary angiography (≥70% luminal stenosis) by receiver operating curve (ROC) analysis.
Of the 3,111 patients who underwent HE SPECT over a 1-year period, 160 patients qualified for the correlation study (66% male, 52% with a history of CAD). The ROC area under the curve (AUC) was similar for both the automated and the visual interpretations using both supine only and combined supine and prone images (0.69-0.74). Using thresholds determined from sensitivity and specificity curves, the automated reads showed higher specificity (59%-67% vs 27%-60%) and lower sensitivity (71%-72% vs 79%-93%) than the visual reads. By including prone images sensitivity decreased slightly but specificity increased for both. By excluding patients with known CAD and cardiomyopathies, AUC and specificity increased for both techniques (0.72-0.82). The use of a difference score to evaluate ischemic burden resulted in lower sensitivities but higher specificities for both automated and visual quantification. There was good agreement between the visual interpretation and automated quantification in the entire cohort of 160 unselected consecutive patients (r = 0.70-0.81, P < .0001).
Automated and visual quantification of high-efficiency SPECT MPI with the GE Discovery camera provides similar overall diagnostic accuracy when compared to coronary angiography. There was good correlation between the two methods of assessment. Combined supine and prone stress imaging provided the best diagnostic accuracy.
Publisher
Elsevier Inc,Springer US,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.