Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
49 result(s) for "Krombach, G. A."
Sort by:
Very pronounced bowel sparing during radiation therapy for anal carcinoma using a natural spacer (Myoma) – a case report
Background Using dose-painted intensity-modulated radiation therapy, specific dose volume constraints or implantation of tissue expanders prior to radiotherapy are validated options for reducing radiation dose on the bowel and therefore minimizing acute gastrointestinal toxicity during chemoradiation for anorectal malignancies. We describe the rare case of a female patient with a locally advanced anal carcinoma where a large myomatous uterus served as a natural spacer to protect the bowel during radiation therapy. Case presentation Initially the patient presented with anal pain, proctoscopy followed by an excisional biopsy confirmed the diagnosis of a squamous cell carcinoma of the anus. Imaging examination showed a locally advanced tumor and in addition a large uterus with typical leiomyomas up to 11.5 cm in diameter. The patient underwent chemoradiation; because of the large leiomyomas there was almost no dose burden for the small intestine and therefore practically no gastrointestinal toxicity. Conclusion As we know, this report describes the situation that a large myomatous uterus served as a natural spacer during radiation therapy in a way that is unique to date.
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
Purpose The combination of positron emission tomography (PET) and magnetic resonance (MR) tomography in a single device is anticipated to be the next step following PET/CT for future molecular imaging application. Compared to CT, the main advantages of MR are versatile soft tissue contrast and its capability to acquire functional information without ionizing radiation. However, MR is not capable of measuring a physical quantity that would allow a direct derivation of the attenuation values for high-energy photons. Methods To overcome this problem, we propose a fully automated approach that uses a dedicated T1-weighted MR sequence in combination with a customized image processing technique to derive attenuation maps for whole-body PET. The algorithm automatically identifies the outer contour of the body and the lungs using region-growing techniques in combination with an intensity analysis for automatic threshold estimation. No user interaction is required to generate the attenuation map. Results The accuracy of the proposed MR-based attenuation correction (AC) approach was evaluated in a clinical study using whole-body PET/CT and MR images of the same patients ( n  = 15). The segmentation of the body and lung contour (L-R directions) was evaluated via a four-point scale in comparison to the original MR image (mean values >3.8). PET images were reconstructed using elastically registered MR-based and CT-based (segmented and non-segmented) attenuation maps. The MR-based AC showed similar behaviour as CT-based AC and similar accuracy as offered by segmented CT-based AC. Standardized uptake value (SUV) comparisons with reference to CT-based AC using predefined attenuation coefficients showed the largest difference for bone lesions (mean value ± standard variation of SUV max : −3.0% ± 3.9% for MR; −6.5% ± 4.1% for segmented CT). A blind comparison of PET images corrected with segmented MR-based, CT-based and segmented CT-based AC afforded identical lesion detectability, but slight differences in image quality were found. Conclusion Our MR‐based attenuation correction method offers similar correction accuracy as offered by segmented CT. According to the specialists involved in the blind study, these differences do not affect the diagnostic value of the PET images.
Sarcopenia of kidney transplant recipients as a predictive marker for reduced graft function and graft survival after kidney transplantation
PurposeThe association between sarcopenia of kidney transplant recipients and outcome after kidney transplantation (KT) has not yet been fully understood and is still considered controversial. The aim of our study was to analyze the impact of pre-transplant sarcopenia on graft function, postoperative complication rates, and survival of the patients after renal transplantation.MethodsIn this retrospective single-center study, all patients who underwent KT (01/2013–12/2017) were included. Demographic data, rejection rates, delayed graft function, and graft and patient survival rates were analyzed. Sarcopenia was measured in computed tomography images by the sex-adjusted Hounsfield unit average calculation (HUAC).ResultsDuring the study period, 111 single KTs (38 women and 73 men) were performed. Living donor kidney transplants were performed in 48.6%. In total, 32.4% patients had sarcopenia. Sarcopenic patients were significantly older (59.6 years vs. 49.8 years; p < 0.001), had a higher body mass index (BMI = 27.6 kg/m2 vs. 25.0 kg/m2; p = 0.002), and were more likely to receive deceased donor kidneys (72.2% vs. 41.3%; p = 0.002). Interestingly, 3 years after KT, the creatinine serum levels were significantly higher (2.0 mg/dl vs. 1.5 mg/dl; p = 0.001), whereas eGFR (39.9 ml/min vs. 53.4 ml/min; p = 0.001) and graft survival were significantly lower (p = 0.004) in sarcopenic transplant recipients. Sarcopenic patients stayed in hospital significantly longer postoperatively than those who were non-sarcopenic.ConclusionsAt the time of kidney transplantation, sarcopenia was found to predict reduced long-term graft function and diminished graft survival after KT. The early identification of sarcopenic patients can not only enable an optimized selection of recipients, but also the initiation of pre-habilitation programs during the waiting period.
The impact of early surgical intervention in free intestinal perforation: a time-to-intervention pilot study
Purposes An abdominal inflammatory focus is the second most often source of sepsis with a high risk of death in surgical intensive care units. By establishing evidence-based bundled strategies the surviving sepsis campaign provided an optimized rapid and continuous treatment of these emergency patients. Hereby the hospital mortality decreased from 35 to 30 %. Sepsis treatment is based on three major therapeutic elements: surgical treatment (source control), antiinfective treatment, and supportive care. The international guidelines of the surviving sepsis campaign were updated recently and recommend rapid diagnosis of the infection and source control within the first 12 h after the diagnosis (grade 1c). Interestingly this recommendation is mainly based on studies on soft tissue infections. Methods In this retrospective analysis 76 septic patients with an intraabdominal inflammatory focus were included. All patients underwent surgery at different time-points after diagnosis. Results With 80 % patients of the early intervention group had an improved overall survival (vs. 73 % in the late intervention group). Conclusions Literature on the time dependency of early source control is rare and in part contradicting. Results of this pilot study reveal that immediate surgical intervention might be of advantage for septic emergency patients. Further multi-center approaches will be necessary to evaluate, whether the TTI has any impact on the outcome of septic patients with intestinal perforation.
Correlation of native T1 mapping with right ventricular function and pulmonary haemodynamics in patients with chronic thromboembolic pulmonary hypertension before and after balloon pulmonary angioplasty
ObjectivesThe aim of this study was to assess native T1 mapping in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) before and 6 months after balloon pulmonary angioplasty (BPA) and compare the results with right heart function and pulmonary haemodynamics.MethodsMagnetic resonance imaging at 1.5 T and right heart catheterisation were performed in 21 consecutive inoperable CTEPH patients before and 6 months after BPA. T1 values were measured within the septal myocardium, the upper and lower right ventricular insertion points, and the lateral wall at the basal short-axis section. In addition, the area-adjusted septal native T1 time (AA-T1) was calculated and compared with right ventricular function (RVEF), mean pulmonary arterial pressure (mPAP) and pulmonary vascular resistance (PVR).ResultsThe mean AA-T1 value decreased significantly after BPA (1,045.8 ± 44.3 ms to 1,012.5 ± 50.4 ms; p < 0.001). Before BPA, native T1 values showed a moderate negative correlation with RVEF (r = -0.61; p = 0.0036) and moderate positive correlations with mPAP (r = 0.59; p < 0.01) and PVR (r = 0.53; p < 0.05); after BPA correlation trends were present (r = -0.21, r = 0.30 and r = 0.35, respectively).ConclusionsNative T1 values in patients with inoperable CTEPH were significantly lower after BPA and showed significant correlations with RVEF and pulmonary haemodynamics before BPA. Native T1 mapping seems to be indicative of reverse myocardial tissue remodelling after BPA and might therefore have good potential for pre-procedural patient selection, non-invasive therapy monitoring and establishing a prognosis.Key Points• BPA is a promising treatment option for patients with inoperable CTEPH• Native septal T1 values significantly decrease after BPA and show good correlations with right ventricular function and haemodynamics before BPA• Prognosis and non-invasive therapy monitoring might be supported in the future by native T1 mapping
Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils
We examined to what degree the visualization of anatomic structures in the human knee is improved using 3.0-T magnetic resonance imaging (MRI) and many element RF receive coils as compared to 1.5 T. We imaged 20 knees at 1.5 and 3.0 T using T2-weighted STIR, T2-weighted gradient echo, T1-weighted spin-echo, true-FISP and T2-weighted fast spin echo techniques in conjunction with 32-element RF coil arrays. The 3.0-T examination was considerably faster than its 1.5-T counterpart. A superior subjective visibility at 3.0 T vs 1.5 T was found in 27 of 50 evaluated structures (meniscus, ligaments) with the exception of true-FISP techniques. The 3.0-T examination provided a better visibility (evaluated by blinded consensus-reading by two radiologists) of small structures such as the ligamentum transversum genu. Also, cartilage was better delineated at 3.0 T. A 23% increased average signal-to-noise ratio as assessed using a temporal filter was observed at 3.0 T as compared to 1.5 T. At 3.0 T, imaging of the human knee is faster and results in a subjective visibility of anatomic structures that is superior to and competitive with 1.5 T.
Effect of synthetic bone replacement material of different size on shear stress resistance within impacted native and thermodisinfected cancellous bone: an in vitro femoral impaction bone grafting model
Antibiotic carrier particles of variable size might influence mechanic properties within impacted thermodisinfected and native cancellous bone different. Herafill®G containing calciumsulfate and calciumcarbonate provides high local concentrations of gentamicin being important for revision surgery in infected joint replacements. Native and thermodisinfected cancellous bone derived from 6 to 7 months old piglets was used for in vitro impaction bone grafting and supplemented each with Herafill®G granules of two different sizes. Micromovement of implants related to shear force was measured in 29 specimens distributed in 6 groups. Thermodisinfected cancellous bone revealed a significant higher shear force resistance than native bone with a mean difference of 423.8 mdeg/Nm (p < 0.001) ranging within 95% confidence interval from 181.5 to 666.0 mdeg/Nm. Adding small granules to thermodisinfected bone did not reduce shear force resistance significantly since adding large granules to native bone improved it by 344.0 mdeg/Nm (p < 0.003). Shear force resistance was found higher at the distal region of the implant compared to a proximal point of measurement throughout all specimens. Less impaction impulses were necessary for thermodisinfected bone. Thermodisinfected cancellous bone might achieve a higher degree of impaction compared with native bone resulting in increased resistance against shear force since impaction was found increased distally. Supplementation of thermodisinfected bone with small granules of Herafill®G might be considered for application of local antibiotics. Large granules appeared more beneficial for supplementation of native bone. Heterogeneity of bone graft and technical aspects of the impaction procedure have to be considered regarding the reproducibility of femoral impaction bone grafting.
Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence
The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo ( n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus ( n=183) or symptoms unrelated to the labyrinth ( n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence.
Virtual endoscopy combined with intraoperative neuronavigation for planning of endoscopic surgery in patients with occlusive hydrocephalus and intracranial cysts
We assessed the clinical value of MR ventriculoscopy (virtual endoscopy, VE) combined with image-guided frameless stereotaxy for endoscopic surgery of occlusive hydrocephalus and intracranial cysts. VE was obtained in 20 patients with hydrocephalus and three with intracranial cysts. All surgical operations were endoscopic. The path of the rigid endoscope to the target point was planned using neuronavigation. VE was carried out along the same trajectory retrospectively in 20 cases and prospectively in three. The results were analysed for demonstration of anatomical landmarks and structures at risk. VE was successful in all patients. Possible obstacles to endoscopic access to the lamina terminalis and the basal cisterns and structures at risk, such as the basilar artery, were clearly shown in relation to the direction of the endoscope. However, the floor of the third ventricle and septum pellucidum were not clearly seen and possible abnormalities could therefore not be appreciated. VE can provide realistic simulation of endoscopic third ventriculostomy and cystostomy. The appropriate trepanation point and trajectory of the endoscope can be assessed with regard to the size of the foramen of Monro and the position of vulnerable structures. This simulated trajectory can be adapted to the field of operation by image-guided neuronavigation. This regime may potentially reduce the risk of damage to intracranial structures.
Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence.