Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
45 result(s) for "Mizukami, Shinya"
Sort by:
Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
We developed a novel dual-energy (DE) virtual monochromatic (VM) very-deep super-resolution (VDSR) method with an unsharp masking reconstruction algorithm (DE–VM–VDSR) that uses projection data to improve the nodule contrast and reduce ripple artifacts during chest digital tomosynthesis (DT). For estimating the residual errors from high-resolution and multiscale VM images from the projection space, the DE–VM–VDSR algorithm employs a training network (mini-batch stochastic gradient-descent algorithm with momentum) and a hybrid super-resolution (SR) image [simultaneous algebraic reconstruction technique (SART) total-variation (TV) first-iterative shrinkage–thresholding algorithm (FISTA); SART–TV–FISTA] that involves subjective reconstruction with bilateral filtering (BF) [DE–VM–VDSR with BF]. DE-DT imaging was accomplished by pulsed X-ray exposures rapidly switched between low (60 kV, 37 projection) and high (120 kV, 37 projection) tube-potential kVp by employing a 40° swing angle. This was followed by comparison of images obtained employing the conventional polychromatic filtered backprojection (FBP), SART, SART–TV–FISTA, and DE–VM–SART–TV–FISTA algorithms. The improvements in contrast, ripple artifacts, and resolution were compared using the signal-difference-to-noise ratio (SDNR), Gumbel distribution of the largest variations, radial modulation transfer function (radial MTF) for a chest phantom with simulated ground-glass opacity (GGO) nodules, and noise power spectrum (NPS) for uniform water phantom. The novel DE–VM–VDSR with BF improved the overall performance in terms of SDNR (DE–VM–VDSR with BF: 0.1603, without BF: 0.1517; FBP: 0.0521; SART: 0.0645; SART–TV–FISTA: 0.0984; and DE–VM–SART–TV–FISTA: 0.1004), obtained a Gumbel distribution that yielded good images showing the type of simulated GGO nodules used in the chest phantom, and reduced the ripple artifacts. The NPS of DE–VM–VDSR with BF showed the lowest noise characteristics in the high-frequency region (~0.8 cycles/mm). The DE–VM–VDSR without BF yielded an improved resolution relative to that of the conventional reconstruction algorithms for radial MTF analysis (0.2–0.3 cycles/mm). Finally, based on the overall image quality, DE–VM–VDSR with BF improved the contrast and reduced the high-frequency ripple artifacts and noise.
Verification of dose distribution in high dose-rate brachytherapy for cervical cancer using a normoxic N-vinylpyrrolidone polymer gel dosimeter
The polymer gel dosimeter has been proposed for use as a 3D dosimeter for complex dose distribution measurement of high dose-rate (HDR) brachytherapy. However, various shapes of catheter/applicator for sealed radioactive source transport used in clinical cases must be placed in the gel sample. The absorbed dose readout for the magnetic resonance (MR)-based polymer gel dosimeters requires calibration data for the dose-transverse relaxation rate (R2) response. In this study, we evaluated in detail the dose uncertainty and dose resolution of three calibration methods, the multi-sample and distance methods using the Ir-192 source and the linear accelerator (linac) method using 6MV X-rays. The use of Ir-192 sources increases dose uncertainty with steep dose gradients. We clarified that the uniformly irradiated gel sample improved the signal-to-noise ratio (SNR) due to the large slice thickness of MR images and could acquire an accurate calibration curve using the linac method. The curved tandem and ovoid applicator used for intracavitary irradiation of HDR brachytherapy for cervical cancer were reproduced with a glass tube to verify the dose distribution. The results of comparison with the treatment planning system (TPS) calculation by gamma analysis on the 3%/2 mm criterion were in good agreement with a gamma pass rate of 90%. In addition, the prescription dose could be evaluated accurately. We conclude that it is easy to place catheter/applicator in the polymer gel dosimeters, making them a useful tool for verifying the 3D dose distribution of HDR brachytherapy with accurate calibration methods.
Development of a denoising convolutional neural network-based algorithm for metal artifact reduction in digital tomosynthesis for arthroplasty: A phantom study
The present study aimed to develop a denoising convolutional neural network metal artifact reduction hybrid reconstruction (DnCNN-MARHR) algorithm for decreasing metal objects in digital tomosynthesis (DT) for arthroplasty by using projection data. For metal artifact reduction (MAR), we implemented a DnCNN-MARHR algorithm based on a training network (mini-batch stochastic gradient descent algorithm with momentum) to estimate the residual reference (140 keV virtual monochromatic [VM]) and object (70 kV with metal artifacts) images. For this, we used projection data and subtracted the estimated residual images from the object images, involving hybrid and subjectively reconstructed image usage (back projection and maximum likelihood expectation maximization [MLEM]). The DnCNN-MARHR algorithm was compared with the dual-energy material decomposition reconstruction algorithm (DEMDRA), VM, MLEM, established and commonly used filtered back projection (FBP), and a simultaneous algebraic reconstruction technique-total variation (SART-TV) with MAR processing. MAR was compared using artifact index (AI) and texture analysis. Artifact spread functions (ASFs) for images that were out-of-plane and in-focus were evaluated using a prosthesis phantom. The overall performance of the DnCNN-MARHR algorithm was adequate with regard to the ASF, and the derived images showed better results, without being influenced by the metal type (AI was almost equal to the best value for the DEMDRA). In the ASF analysis, the DnCNN-MARHR algorithm generated better MAR compared with that obtained employing usual algorithms for reconstruction using MAR processing. In addition, comparison of the difference (mean square error) between DnCNN-MARHR and the conventional algorithm resulted in the smallest VM. The DnCNN-MARHR algorithm showed the best performance with regard to image homogeneity in the texture analysis. The proposed algorithm is particularly useful for reducing artifacts in the longitudinal direction, and it is not affected by tissue misclassification.
Amygdala-centred functional connectivity affects daily cortisol concentrations: a putative link with anxiety
The amygdala plays a critical role in emotion. Its functional coupling with the hippocampus and ventromedial prefrontal cortex extending to a portion of the anterior cingulate cortex (ACC) is implicated in anxiogenesis and hypothalamic-pituitary-adrenal (HPA) system regulation. However, it remains unclear how amygdala-centred functional connectivity (FC) affects anxiety and cortisol concentrations in everyday life. Here, we investigate the relationship between daily cortisol concentrations (dCOR) and amygdala-centred FC during emotional processing in forty-one healthy humans. FC analyses revealed that higher dCOR predicted strengthened amygdala-centred FC with the hippocampus and cerebellum, but inhibited FC with the supramarginal gyrus and a perigenual part of the ACC (pgACC) when processing fearful faces (vs. neutral faces). Notably, the strength of amygdala-hippocampus FC mediated the positive relationship between cortisol and anxiety, specifically when the effect of amygdala-pgACC FC, a presumptive neural indicator of emotional control, was taken into account. Individuals with diminished connectivity between the amygdala and pgACC during fear-related processing might be more vulnerable to anxiogenesis as it pertains to greater circulating cortisol levels in everyday life. Individual functional patterns of amygdala-hippocampal-pgACC connectivity might provide a key to understand the complicate link between cortisol and anxiety-related behaviors.
Usefulness of a Metal Artifact Reduction Algorithm in Digital Tomosynthesis Using a Combination of Hybrid Generative Adversarial Networks
In this study, a novel combination of hybrid generative adversarial networks (GANs) comprising cycle-consistent GAN, pix2pix, and (mask pyramid network) MPN (CGpM-metal artifact reduction [MAR]), was developed using projection data to reduce metal artifacts and the radiation dose during digital tomosynthesis. The CGpM-MAR algorithm was compared with the conventional filtered back projection (FBP) without MAR, FBP with MAR, and convolutional neural network MAR. The MAR rates were compared using the artifact index (AI) and Gumbel distribution of the largest variation analysis using a prosthesis phantom at various radiation doses. The novel CGpM-MAR yielded an adequately effective overall performance in terms of AI. The resulting images yielded good results independently of the type of metal used in the prosthesis phantom (p < 0.05) and good artifact removal at 55% radiation-dose reduction. Furthermore, the CGpM-MAR represented the minimum in the model with the largest variation at 55% radiation-dose reduction. Regarding the AI and Gumbel distribution analysis, the novel CGpM-MAR yielded superior MAR when compared with the conventional reconstruction algorithms with and without MAR at 55% radiation-dose reduction and presented features most similar to the reference FBP. CGpM-MAR presents a promising method for metal artifact and radiation-dose reduction in clinical practice.
Effect of Breath Holding on Spleen Volume Measured by Magnetic Resonance Imaging
Ultrasonographic studies have demonstrated transient reduction in spleen volume in relation to apnea diving. We measured spleen volume under various respiratory conditions by MR imaging to accurately determine the influence of ordinary breath holding on spleen volumetry. Twelve healthy adult volunteers were examined. Contiguous MR images of the spleen were acquired during free breathing and during respiratory manipulations, including breath holding at the end of normal expiration, breath holding at deep inspiration, and the valsalva maneuver, and spleen volume was measured from each image set based on the sum-of-areas method. Acquisition during free breathing was performed with respiratory triggering. The duration of each respiratory manipulation was 30 s, and five sets of MR images were acquired serially during each manipulation. Baseline spleen volume before respiratory manipulation was 173.0 ± 79.7 mL, and the coefficient of variance for two baseline measures was 1.4% ± 1.6%, suggesting excellent repeatability. Spleen volume decreased significantly just after the commencement of respiratory manipulation, remained constant during the manipulation, and returned to the control value 2 min after the cessation of the manipulation, irrespective of manipulation type. The percentages of volume reduction were 10.2% ± 2.9%, 10.2% ± 3.5%, and 13.3% ± 5.7% during expiration breath holding, deep-inspiration breath holding, and the valsalva maneuver, respectively, and these values did not differ significantly. Spleen volume is reduced during short breath-hold apnea in healthy adults. Physiological responses of the spleen to respiratory manipulations should be considered in the measurement and interpretation of spleen volume.
Whole Three-Dimensional Dosimetry of Carbon Ion Beams with an MRI-Based Nanocomposite Fricke Gel Dosimeter Using Rapid T1 Mapping Method
MRI-based gel dosimeters are attractive systems for the evaluation of complex dose distributions in radiotherapy. In particular, the nanocomposite Fricke gel dosimeter is one among a few dosimeters capable of accurately evaluating the dose distribution of heavy ion beams. In contrast, reduction of the scanning time is a challenging issue for the acquisition of three-dimensional volume data. In this study, we investigated a three-dimensional dose distribution measurement method for heavy ion beams using variable flip angle (VFA), which is expected to significantly reduce the MRI scanning time. Our findings clarified that the whole three-dimensional dose distribution could be evaluated within the conventional imaging time (20 min) and quality of one cross-section.
Biosynthesis of nearly monodispersed poly(ε-l-lysine) in Streptomyces species
Poly(ε- l -lysine) (ε-PL) is a naturally occurring poly(amino acid) characterized by a unique structure linking ε-amino and carboxyl groups of l -lysine. Due to its various functions and its biodegradability and non-toxicity, the ε-PL polymer has attracted increasing attention in recent years. ε-PL is frequently found in various strains of Streptomyces sp. This review gives an up-to-date overview regarding the biosynthesis of ε-PL focussing mainly on results obtained from ten newly isolated producer strains, using the two-stage culture method of cell growth and ε-PL production cultures. The production of nearly monodispersed ε-PL is covered together with the development of ε-PL specific hydrolases and the release of synthesized ε-PL into the culture broth. From these results, coupled with the termination of polymerization through nucleophilic chain transfer, the biosynthetic mechanism of the polymer is discussed.