Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
111
result(s) for
"Peng, Qiyu"
Sort by:
Sensitive monitoring of xenograft cancer models using cell-free DNA
by
Zhu, Wenjing
,
Tang, Bianbian
,
Peng, Qiyu
in
Animal models
,
Biomedical and Life Sciences
,
Biomedicine
2025
Furthermore, biopsies taken after sacrifice did not reveal any tumors, indicating that HCC1937 cells did not form solid tumors. Besides imaging, a human-specific PCR primer set was designed, validated, and utilized in this study to evaluate ctDNA (Suppl. [See PDF for image] Fig. 1 Detection of ctDNA in xenograft mouse models. (a-g) NCG mice engrafted with HCC1937 cells (named m1 to m6, respectively). (a) Study design and experiment timepoints. (b) In vivo imaging results at various timepoints. (c) Positron emission tomography (PET) imaging results at week 12 post engraftment. [...]due to its high sensitivity, ctDNA has been effectively utilized for monitoring minimal residual disease and predicting early cancer relapses [4, 5]. [...]our study highlights the persistence of ctDNA in xenograft mice lacking recognizable tumors, underscoring the limitations of current in vivo imaging methods.
Journal Article
Requirements of Scintillation Crystals with the Development of PET Scanners
2022
Positron emission tomography (PET) is widely used in the diagnosis of tumors, cardiovascular system diseases, and neurological diseases. Scintillation crystals are an important part of PET scanners; they can convert γ photons into fluorescent photons to obtain their energy, time, and position information. Currently, an important research goal in PET is to find scintillation crystals with better performance. In this work, the principle of scintillation crystals is introduced, and the properties and requirements of scintillation crystals in different PET scanners are analyzed. At present, Lu2(1−x)Y2xSiO5 (LYSO) is the scintillation crystal with the best comprehensive properties. LaBr3 performs even better regarding the timing characteristics and light output; however, LaBr3 has not been used in any PET scanner because of its deliquescence. Detectors made of Gd3(Ga, Al)5O12 (GAGG) exhibit a high depth of interaction (DOI) resolution and have considerable application potential. The application fields of PET are constantly expanding, and its future development aims to achieve high spatial resolution and high sensitivity, which require scintillation crystals with better performance.
Journal Article
Evaluation of Various Scintillator Materials in Radiation Detector Design for Positron Emission Tomography (PET)
by
Ying, Gaoyang
,
Huang, Qiu
,
Zhang, Yibin
in
coincidence timing resolution
,
Composition
,
Crystals
2020
The performance of radiation detectors used in positron-emission tomography (PET) is determined by the intrinsic properties of the scintillators, the geometry and surface treatment of the scintillator crystals and the electrical and optical characteristics of the photosensors. Experimental studies were performed to assess the timing resolution and energy resolution of detectors constructed with samples of different scintillator materials (LaBr3, CeBr3, LFS, LSO, LYSO: Ce, Ca and GAGG) that were fabricated into different shapes with various surface treatments. The saturation correction of SiPMs was applied for tested detectors based on a Tracepro simulation. Overall, we tested 28 pairs of different forms of scintillators to determine the one with the best CTR and light output. Two common high-performance silicon photomultipliers (SiPMs) provided by SensL (J-series, 6 mm) or AdvanSiD (NUV, 6 mm) were used for photodetectors. The PET detector constructed with 6 mm CeBr3 cubes achieved the best CTR with a FWHM of 74 ps. The 4 mm co-doped LYSO: Ce, Ca pyramid crystals achieved 88.1 ps FWHM CTR. The 2 mm, 4 mm and 6 mm 0.2% Ce, 0.1% Ca co-doped LYSO cubes achieved 95.6 ps, 106 ps and 129 ps FWHM CTR, respectively. The scintillator crystals with unpolished surfaces had better timing than those with polished surfaces. The timing resolution was also improved by using certain geometric factors, such as a pyramid shape, to improve light transportation in the scintillator crystals.
Journal Article
A Novel Portable Gamma Radiation Sensor Based on a Monolithic Lutetium-Yttrium Oxyorthosilicate Ring
2021
Portable radiation detectors are widely used in environmental radiation detection and medical imaging due to their portability feature, high detection efficiency, and large field of view. Lutetium-yttrium oxyorthosilicate (LYSO) is a widely used scintillator in gamma radiation detection. However, the structure and the arrangement of scintillators limit the sensitivity and detection accuracy of these radiation detectors. In this study, a novel portable sensor based on a monolithic LYSO ring was developed for the detection of environmental radiation through simulation, followed by construction and assessments. Monte Carlo simulations were utilized to prove the detection of gamma rays at 511 keV by the developed sensor. The simulations data, including energy resolutions, decoding errors, and sensitivity, showed good potential for the detection of gamma rays by the as-obtained sensor. The experimental results using the VA method revealed decoding errors in the energy window width of 50 keV less than 2°. The average error was estimated at 0.67°, a sufficient value for the detection of gamma radiation. In sum, the proposed radiation sensor appears promising for the construction of high-performance radiation detectors and systems.
Journal Article
An 8.8 ps RMS Resolution Time-To-Digital Converter Implemented in a 60 nm FPGA with Real-Time Temperature Correction
by
Song, Zhipeng
,
Huang, Qiu
,
Peng, Qiyu
in
BASIC BIOLOGICAL SCIENCES
,
Calibration
,
CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS
2020
This paper presented a non-uniform multiphase (NUMP) time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA) with real-time automatic temperature compensation. NUMP-TDC is a novel, low-cost, high-performance TDC that has achieved an excellent performance in Altera Cyclone V FPGA. The root mean square (RMS) for the intrinsic timing resolution was 2.3 ps. However, the propagation delays in the delay chain of some FPGAs (for example, the Altera Cyclone 10 LP) vary significantly as the temperature changes. Thus, the timing performances of NUMP-TDCs implemented in those FPGAs are significantly impacted by temperature fluctuations. In this study, a simple method was developed to monitor variations in propagation delays using two registers deployed at both ends of the delay chain and compensate for changes in propagation delay using a look-up table (LUT). When the variations exceeded a certain threshold, the LUT for the delay correction was updated, and a bin-by-bin correction was launched. Using this correction approach, a resolution of 8.8 ps RMS over a wide temperature range (5 °C to 80 °C) had been achieved in a NUMP-TDC implemented in a Cyclone 10 LP FPGA.
Journal Article
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
by
Zhang, Yibin
,
Peng, Qiyu
,
Xie, Qiangqiang
in
coincidence timing resolution
,
dual-ended readout
,
Energy
2021
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.
Journal Article
Pathophysiology characterization of Alzheimer’s disease in South China’s aging population: for the Greater-Bay-Area Healthy Aging Brain Study (GHABS)
2024
Introduction
The Guangdong-Hong Kong-Macao Greater-Bay-Area of South China has an 86 million population and faces a significant challenge of Alzheimer’s disease (AD). However, the characteristics and prevalence of AD in this area are still unclear due to the rarely available community-based neuroimaging AD cohort.
Methods
Following the standard protocols of the Alzheimer’s Disease Neuroimaging Initiative, the Greater-Bay-Area Healthy Aging Brain Study (GHABS) was initiated in 2021. GHABS participants completed clinical assessments, plasma biomarkers, genotyping, magnetic resonance imaging (MRI), β-amyloid (Aβ) positron emission tomography (PET) imaging, and tau PET imaging. The GHABS cohort focuses on pathophysiology characterization and early AD detection in the Guangdong-Hong Kong-Macao Greater Bay Area. In this study, we analyzed plasma Aβ
42
/Aβ
40
(A), p-Tau
181
(T), neurofilament light, and GFAP by Simoa in 470 Chinese older adults, and 301, 195, and 70 had MRI, Aβ PET, and tau PET, respectively. Plasma biomarkers, Aβ PET, tau PET, hippocampal volume, and temporal-metaROI cortical thickness were compared between normal control (NC), subjective cognitive decline (SCD), mild cognitive impairment (MCI), and dementia groups, controlling for age, sex, and
APOE-ε4
. The prevalence of plasma A/T profiles and Aβ PET positivity were also determined in different diagnostic groups.
Results
The aims, study design, data collection, and potential applications of GHABS are summarized. SCD individuals had significantly higher plasma p-Tau
181
and plasma GFAP than the NC individuals. MCI and dementia patients showed more abnormal changes in all the plasma and neuroimaging biomarkers than NC and SCD individuals. The frequencies of plasma A+/T+ (NC; 5.9%, SCD: 8.2%, MCI: 25.3%, dementia: 64.9%) and Aβ PET positivity (NC: 25.6%, SCD: 22.5%, MCI: 47.7%, dementia: 89.3%) were reported.
Discussion
The GHABS cohort may provide helpful guidance toward designing standard AD community cohorts in South China. This study, for the first time, reported the pathophysiology characterization of plasma biomarkers, Aβ PET, tau PET, hippocampal atrophy, and AD-signature cortical thinning, as well as the prevalence of Aβ PET positivity in the Guangdong-Hong Kong-Macao Greater Bay Area of China. These findings provide novel insights into understanding the characteristics of abnormal AD pathological changes in South China’s older population.
Journal Article
Development and Evaluation of a Dual-Layer-Offset PET Detector Constructed with Different Reflectors
2022
Dual-layer-offset or multi-layer-offset design of a PET detector can improve spatial resolution while maintaining high sensitivity. In this study, three dual-layer-offset LYSO detectors with three different reflectors (ESR, Toray, and BaSO4) were developed. The top layer consisted of a 17 × 17 array of crystals 1 × 1 × 6.5 mm3 in size and the bottom layer consisted of an 18 × 18 array of crystals 1 × 1 × 9.5 mm3 in size. Neither light guides nor optical glue were used between the two layers of crystals. A custom-designed electronics system, composed of a 6 × 6 SiPM array, two FPC cables, and a custom-designed data processing module, was used to read out signals. An optimized interaction-decoding algorithm using the center of gravity to determine the position and threshold of analog signals for timing methods was applied to generate decoding flood histograms. The detector performances, in terms of peak to valley ratio of the flood histograms and energy resolutions, were calculated and compared. The dual-layer-offset PET detector constructed with BaSO4 reflectors performed much better than the other two reflectors in both crystal identification and energy resolution. The average peak-to-valley ratio and the energy resolution were approximately 7 and 11%, respectively. In addition, the crystals in the bottom layer showed better performance at crystal identification than those in the top layer. This study can act as a reference providing guidance in choosing scintillator reflectors for multi-layer dedicated DOI detectors designed for small-animal PET imaging.
Journal Article
Quantitative evaluations of ankle spasticity and stiffness in neurological disorders using manual spasticity evaluator
2011
Spasticity and contracture are major sources of disability in people with neurological impairments that have been evaluated using various instruments: the Modified Ashworth Scale, tendon reflex scale, pendulum test, mechanical perturbations, and passive joint range of motion (ROM). These measures generally are either convenient to use in clinics but not quantitative or they are quantitative but difficult to use conveniently in clinics. We have developed a manual spasticity evaluator (MSE) to evaluate spasticity/contracture quantitatively and conveniently, with ankle ROM and stiffness measured at a controlled low velocity and joint resistance and Tardieu catch angle measured at several higher velocities. We found that the Tardieu catch angle was linearly related to the velocity, indicating that increased resistance at higher velocities was felt at further stiffer positions and, thus, that the velocity dependence of spasticity may also be position-dependent. This finding indicates the need to control velocity in spasticity evaluation, which is achieved with the MSE. Quantitative measurements of spasticity, stiffness, and ROM can lead to more accurate characterizations of pathological conditions and outcome evaluations of interventions, potentially contributing to better healthcare services for patients with neurological disorders such as cerebral palsy, spinal cord injury, traumatic brain injury, and stroke.
Journal Article
Waste Plastic Recycling Upgrade Design Nanogenerator for Catalytic Degradation of Pollutants
2023
In recent years, electrocatalytic degradation of pollutants based on nanogenerators has gradually emerged. Compared with the huge energy consumption of traditional electrocatalysis, this method can effectively use displacement current to induce charge transfer and complete catalysis, so it can directly use the existing water flow energy and other energy sources in nature. This work will explain the basic principles, methods, and measurement methods of preparing nanogenerators from waste plastics, as well as the classification of electrocatalytic principles and methods relative to nanogenerators, which provides important support for the research in this emerging field. At the same time, the analysis based on this knowledge will also lay the foundation for future design.
Journal Article