Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
by
Zhang, Yibin
, Peng, Qiyu
, Xie, Qiangqiang
, Yu, Hongsen
, Xu, Jianfeng
, Xie, Siwei
, Zhang, Xi
, Zhu, Zhiliang
in
coincidence timing resolution
/ dual-ended readout
/ Energy
/ optical simulation
/ Optics
/ positron emission tomography
/ Sensors
/ Simulation
/ time of flight
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
by
Zhang, Yibin
, Peng, Qiyu
, Xie, Qiangqiang
, Yu, Hongsen
, Xu, Jianfeng
, Xie, Siwei
, Zhang, Xi
, Zhu, Zhiliang
in
coincidence timing resolution
/ dual-ended readout
/ Energy
/ optical simulation
/ Optics
/ positron emission tomography
/ Sensors
/ Simulation
/ time of flight
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
by
Zhang, Yibin
, Peng, Qiyu
, Xie, Qiangqiang
, Yu, Hongsen
, Xu, Jianfeng
, Xie, Siwei
, Zhang, Xi
, Zhu, Zhiliang
in
coincidence timing resolution
/ dual-ended readout
/ Energy
/ optical simulation
/ Optics
/ positron emission tomography
/ Sensors
/ Simulation
/ time of flight
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
Journal Article
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
2021
Request Book From Autostore
and Choose the Collection Method
Overview
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.
Publisher
MDPI AG,MDPI
This website uses cookies to ensure you get the best experience on our website.