Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
350
result(s) for
"Redaelli, Andrea"
Sort by:
Phase transitions and chemical segregation in Ge-rich GST based phase change memory cells
by
Claverie, Alain
,
Luong, Minh-Anh
,
Laurin, Luca
in
639/301/1005/1007
,
639/301/1005/1008
,
Chemical analysis
2025
In this work, a detailed chemical and crystallographic analysis of basic logic and a few selected intermediate RESET states of Ge-rich Ge-Sb-Te-based (GST) phase-change memories (PCM) is presented, with a particular focus on the understanding of the microscopic mechanisms underlying their electrical characteristics. We demonstrate that Ge-rich GST-based PCM store the information not only in their crystalline or amorphous phase, as in conventional PCM based on Ge
2
Sb
2
Te
5
, but also in their active material stoichiometries: the amorphous phase is characterized by a Ge-rich composition, guaranteeing automotive-compliant retention, while the crystalline phase shows a composite structure, made of cubic GST and rhombohedral Sb grains, the latter mostly found close to the heater. This switching of composition explains the high temperature retention capability of Ge-rich GST cells and their preserved good functionality in the high conductive state. Analysis of intermediate RESET states unveils the microscopic details of these physical and chemical transitions, giving insights on the physical origin of the electrical characteristics of Ge-rich GST-based PCM.
Journal Article
Revisiting the Local Structure in Ge-Sb-Te based Chalcogenide Superlattices
by
Bragaglia, Valeria
,
Yu, Xiaoming
,
Kooi, Bart J.
in
140/146
,
639/301/1005/1008
,
639/766/119/544
2016
The technological success of phase-change materials in the field of data storage and functional systems stems from their distinctive electronic and structural peculiarities on the nanoscale. Recently, superlattice structures have been demonstrated to dramatically improve the optical and electrical performances of these chalcogenide based phase-change materials. In this perspective, unravelling the atomistic structure that originates the improvements in switching time and switching energy is paramount in order to design nanoscale structures with even enhanced functional properties. This study reveals a high- resolution atomistic insight of the [GeTe/Sb
2
Te
3
] interfacial structure by means of Extended X-Ray Absorption Fine Structure spectroscopy and Transmission Electron Microscopy. Based on our results we propose a consistent novel structure for this kind of chalcogenide superlattices.
Journal Article
Diagnostic Approach and Differences between Spinal Infections and Tumors
2023
Study design: A systematic review of the literature about differential diagnosis between spine infection and bone tumors of the spine. Background and Purpose: The differential diagnosis between spine infection and bone tumors of the spine can be misled by the prevalence of one of the conditions over the other in different areas of the world. A review of the existing literature on suggestive or even pathognomonic imaging aspects of both can be very useful for correctly orientating the diagnosis and deciding the most appropriate area for biopsy. The purpose of our study is to identify which imaging technique is the most reliable to suggest the diagnosis between spine infection and spine bone tumor. Methods: A primary search on Medline through PubMed distribution was made. We identified five main groups: tuberculous, atypical spinal tuberculosis, pyogenic spondylitis, and neoplastic (primitive and metastatic). For each group, we evaluated the commonest localization, characteristics at CT, CT perfusion, MRI, MRI with Gadolinium, MRI diffusion (DWI) and, in the end, the main features for each group. Results: A total of 602 studies were identified through the database search and a screening by titles and abstracts was performed. After applying inclusion and exclusion criteria, 34 articles were excluded and a total of 22 full-text articles were assessed for eligibility. For each article, the role of CT-scan, CT-perfusion, MRI, MRI with Gadolinium and MRI diffusion (DWI) in distinguishing the most reliable features to suggest the diagnosis of spine infection versus bone tumor/metastasis was collected. Conclusion: Definitive differential diagnosis between infection and tumor requires biopsy and culture. The sensitivity and specificity of percutaneous biopsy are 72% and 94%, respectively. Imaging studies can be added to address the diagnosis, but a multidisciplinary discussion with radiologists and nuclear medicine specialists is mandatory.
Journal Article
How to Reduce the Risk of Mechanical Failures in Adult Deformity Surgery: Comparing GAP Score and Roussouly Type Restoration
2025
Study Design
Retrospective Cohort Study.
Objectives
To assess long-term alignment descriptors correlating with mechanical complications.
Methods
The study included adult spinal deformity cases older than 18, with a minimum of four instrumented levels and a 5-year follow-up. Exclusions: previous spinal fusion, neuromuscular/rheumatic diseases, active infections, tumors, or incomplete radiographic exams. Collected data: demographic, surgical, pre- and post-operative spinopelvic parameters, and post-operative complications. The GAP score, original Roussouly type restoration, Schwab’s criteria, and Odontoid to hip axis angle were evaluated using machine learning and logistic regression. Complications were evaluated with a Kaplan-Meier curve.
Results
Two hundred and twelve patients fulfilled the inclusion and exclusion criteria and were enrolled in the study. The observed rate of revision surgery for mechanical complications was 40.6% (86 out of 212 patients). Higher post-operative GAP scores were associated with increased risks of revision for junctional failure (AUC = 0.72 [IC 95%] 0.62-0.80). The inability to restore the original Roussouly spinal shape was statistically associated with higher mechanical failure rates. A machine-learning approach and subsequent logistic regression found that the GAP score and original Roussouly type restoration are the most important predictors for mechanical failure, and GAP score lordosis distribution index and relative pelvic version are the most important factors to predict the risk of mechanical failure.
Conclusions
In our series, a proper post-operative GAP Score and the restoration of the original Roussouly type significantly minimize mechanical complication rates. We observed that junctional failure tends to occur earlier among complications, while implant failure occurs later in the follow-up.
Journal Article
The Positive Side Effect of Anterior Cervical Decompression and Fusion on Axial Neck Pain
by
Vanni, Daniele
,
Barile, Francesca
,
Lepori, Paolo
in
Back surgery
,
Neck pain
,
Original Research
2025
Study Design
Observational Cohort Study.
Objectives
This study aims to comprehensively assess the outcomes of anterior cervical spine surgery in patients who have undergone surgical intervention for radiculopathy or myelopathy, with a specific focus on the surgery’s impact on axial neck pain.
Methods
Data from an institutional spine surgery registry were analyzed for patients who underwent anterior cervical spine surgery between January 2016 and March 2022. Patient demographics, clinical variables, and outcome measures, including the Neck Disability Index (NDI), numeric rating scales for neck and arm pain (NRS-Neck and NRS-Arm), and 36-Item Short Form Health Survey (SF-36) scores, were collected. Statistical analysis included paired t-tests, chi-squared tests, and multivariate linear regression.
Results
Of 257 patients, 156 met the inclusion criteria. Patients showed significant improvement in NDI, NRS-Neck, NRS-Arm, SF-36 (Physical and Mental components), and all changes exceeded the minimum clinically important difference. Multivariate regression revealed that lower preoperative physical and mental component scores and higher preoperative NRS-Neck predicted worse NDI scores at follow-up.
Conclusions
This study underscores that anterior cervical fusion not only effectively alleviates arm pain and disability but also has a positive impact on axial neck pain, which may not be the primary target of surgery. Our findings emphasize the potential benefits of surgical intervention when neck pain coexists with neurologic compression. This contribution adds to the growing body of evidence emphasizing the importance of precise diagnosis and patient selection. Future research, ideally focusing on patients with isolated neck pain, should further explore alternative surgical approaches to enhance treatment options.
Journal Article
Pedicle screw insertion with patient-specific 3D-printed guides based on low-dose CT scan is more accurate than free-hand technique in spine deformity patients: a prospective, randomized clinical trial
by
Zerbi, Alberto
,
Redaelli, Andrea
,
Cecchinato, Riccardo
in
Bone surgery
,
Clinical trials
,
Computed tomography
2019
BackgroundScrew misplacement incidence can be as high as 15–30% in spine deformity surgery, with possible devastating consequences. Some technical solutions to prevent misplacement require expensive devices. MySpineTM comprises a low-dose CT scan of the patient’s spine to build a virtual model of the spine to plan the screw trajectories and a 3D-printed patient-specific guide system to prepare the screw trajectories and to implant the screws in the vertebrae in order to increase reproducibility and safety of the implants. The aim of this open-label, single-center, prospective randomized clinical trial with independent evaluation of outcomes was to compare the accuracy of free-hand insertion of pedicle screws to MySpineTM 3D-printed patient-specific guides.MethodsTwenty-nine patients undergoing surgical correction for spinal deformity were randomized to Group A (pedicle screws implantation with MySpineTM) or Group B (free-hand implantation). Group A received 297 pedicle screws, and Group B 243 screws. Forty-three screws in Group A crossed over to free-hand implantation. Screw position was graded according to Gertzbein in grades 0, A, B or C, with grades 0 or A considered as “safe area.” Total fluoroscopy dose and time were compared in six patients of each group.ResultsComparing the two study groups, we observed a statistically significant difference between the two groups (p < 0.05), with 96.1% of screws in the “safe area” in Group A versus a 82.9% in Group B. Group-A patients had a mean effective dose of 0.23 mSv compared to 0.82 mSv in Group B. Patient-specific, 3D-printed pedicle screw guides increase safety in a wide spectrum of deformity conditions. In addition, the total radiation dose is reduced, even considering the need of a low-dose preoperative CT for surgical planning.Level of evidenceI.Graphical abstractThese slides can be retrieved under Electronic Supplementary Material.
Journal Article
Is neck pain treatable with surgery?
by
Stephan, Stephen R.
,
Redaelli, Andrea
,
Riew, K. Daniel
in
Arthritis
,
Back surgery
,
Bone surgery
2024
Introduction
Neck pain is one of the most common complaints in clinical practice and can be caused by a wide variety of conditions. While cervical spine surgery is a well-accepted option for radicular pain and myelopathy, surgery for isolated neck pain is controversial. The identification of the source of pain is challenging and subtle, and misdiagnosis can lead to inappropriate treatment.
Materials and methods and results
We conducted a thorough literature review to discuss and compare different causes of neck pain. We then supplemented the literature with our senior author’s expert analysis of treating cervical spine pathology.
Conclusions
This study provides an in-depth discussion of neck pain and its various presentations, as well as providing insight into treatment strategies and diagnostic pearls that may prevent mistreatment of cervical spine pathology.
Journal Article
The problems associated with revision surgery
2020
This article highlights the issue related to revision surgery in spine and the possible implications in the next future.Graphic abstractThese slides can be retrieved under Electronic Supplementary Material.
Journal Article
Complications in endoscopic spine surgery: a systematic review
by
Ponzo, Matteo
,
Peretti, Giuseppe Maria
,
Vanni, Daniele
in
Back surgery
,
Bone surgery
,
Decompression
2024
Purpose
This systematic review aims to investigate the complication rate of endoscopic spine surgeries, stratifying them by technique, district and kind of procedure performed.
Methods
This study was conducted according to the PRISMA statement. The literature search was conducted in MEDLINE, CINAHL, EMBASE, Cochrane Register, OTseeker and ScienceDirect database. Types of studies included were observational studies (cohort studies, case–control studies and case series) and randomised or quasi-randomised clinical with human subjects. No restrictions on publication year were applied. Repeated articles, reviews, expert's comments, congress abstracts, technical notes and articles not in English were excluded. Several data were extracted from the articles. In particular, data of perioperative (≤ 3 months) and late (> 3 months) complications were collected and grouped according to: (1) surgical technique [uniportal full-endoscopic spine surgery (UESS) or unilateral biportal endoscopic spine surgery (UBESS)]; (2) spinal district treated [cervical, thoracic or lumbar] and (3) type of procedure [discectomy/decompression or fusion]. Complication analysis was performed in subgroups with at least 100 patients to have clinically meaningful statistical validity.
Results
A total of 117 full-text articles were assessed for eligibility. Of the 117 records included, 95 focused their research on UESS (14 LOE V, 33 LOE IV, 43 LOE III and five LOE II) and 23 on UBESS (three LOE V, eight LOE IV, 10 LOE III and two LOE II). A total of 20,020 patients were extracted to investigate the incidence of different perioperative and late complications, 10,405 for UESS and 9615 for UBESS.
Conclusion
The present study summarises the complications reported in the literature for spinal endoscopic procedures. On the one hand, the most relevant described were perioperative complications (transient neurological deficit, dural tear and dysesthesia) that are especially meaningful for endoscopic discectomy and decompression. On the other hand, late complications, such as mechanical implant failure, are more common in endoscopic interbody fusion.
Level of Evidence
I.
Journal Article