Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
54
result(s) for
"Sethi, Amrita"
Sort by:
Advanced Endoscopic Procedures in Pregnancy
2022
Sex-dependent increased lithogenicity is attributed to the female sex hormones (3). [...]pregnancy, a high estrogen and progesterone state, is a major risk factor for biliary stone formation. According to the American College of Obstetricians and Gynecologists, “exposure to less than 5 rad [50 mGy] has not been associated with an increase in fetal anomalies, growth restriction or abortion” (13). Draping the lower abdomen and pelvis reduces the exposure to the uterus, although most of the radiation exposure to the fetus comes from radiation scattered by the pregnant patient. [...]ancillary strategies (Table 1) to mitigate the risk of radiation exposure further should be implemented.Table 1. Pregnancy was an independent risk factor with an odds ratio of 2.8 (confidence interval [CI] 2.1–3.8) (27). The challenges with these techniques include inability to exclude cystic duct cannulation with wire and confirmation of ductal clearance. [...]some have described the safe use of cholangioscopy for the confirmation of selective ductal cannulation and clearance (23).
Journal Article
Accuracy in Polyp Size Measurement Among Surgeons, Gastroenterologists, Trainees, and Experts: A Prospective Video-Based Study
2024
INTRODUCTION:Polyp size determination plays an important role in endoscopic decision making and follow-up determination. However, there is a lack of knowledge of endoscopist accuracy for polyp sizing and efficacy of available tools for size measurement. Our aim was to compare the accuracy of visual assessment, snare, forceps, and virtual scale endoscope (VSE) in estimating polyp size among a diverse group of endoscopists.METHODS:We conducted a prospective video-based study. One hundred twenty polyps measured and recorded along with all available measurement tools were randomized to visual assessment, snare, forceps, or VSE group. Eleven endoscopists conducted video-based measurement using the randomized measurement tool. Primary outcome was relative accuracy in polyp size measurement compared with caliper measurement immediately postresection.RESULTS:One thousand three hundred twenty measurements were performed. VSE had statistically significantly higher relative accuracy when compared to forceps (79.3 vs 71.3%; P < 0.0001). Forceps had statistically significantly higher relative accuracy when compared to visual assessment (71.3 vs 63.6%; P = 0.0036). There was no statistically significant difference when comparing visual assessment and snare-based measurements (63.6 vs 62.8%; P = 0.797). Overall, 21.5% of polyps >5 mm were misclassified as ≤5 mm and 17.3% of polyps ≥10 mm were misclassified as <10 mm. VSE had the lowest percentage of polyps >5 mm misclassified as ≤5 mm (2.6%), polyps ≤5 mm misclassified as >5 mm (5.1%), and polyps <10 mm misclassified as ≥10 mm (1.7%).DISCUSSION:Visual size estimation of polyps is inaccurate independently of training level, sex, and specialty. Size measurement accuracy can be improved using forceps and yields the highest relative accuracy when an adaptive scale technology is used.
Journal Article
Acute Pancreatitis Task Force on Quality: Development of Quality Indicators for Acute Pancreatitis Management
by
Habash, Samar
,
Hawes, Robert H.
,
Reddy, Rathan
in
Advisory Committees
,
Analgesics - therapeutic use
,
Anti-Bacterial Agents - therapeutic use
2019
Detailed recommendations and guidelines for acute pancreatitis (AP) management currently exist. However, quality indicators (QIs) are required to measure performance in health care. The goal of the Acute Pancreatitis Task Force on Quality was to formally develop QIs for the management of patients with known or suspected AP using a modified version of the RAND/UCLA Appropriateness Methodology.
A multidisciplinary expert panel composed of physicians (gastroenterologists, hospitalists, and surgeons) who are acknowledged leaders in their specialties and who represent geographic and practice setting diversity was convened. A literature review was conducted, and a list of proposed QIs was developed. In 3 rounds, panelists reviewed literature, modified QIs, and rated them on the basis of scientific evidence, bias, interpretability, validity, necessity, and proposed performance targets.
Supporting literature and a list of 71 proposed QIs across 10 AP domains (Diagnosis, Etiology, Initial Assessment and Risk Stratification, etc.) were sent to the expert panel to review and independently rate in round 1 (95% of panelists participated). Based on a round 2 face-to-face discussion of QIs (75% participation), 41 QIs were classified as valid. During round 3 (90% participation), panelists rated the 41 valid QIs for necessity and proposed performance thresholds. The final classification determined that 40 QIs were both valid and necessary.
Hospitals and providers managing patients with known or suspected AP should ensure that patients receive high-quality care and desired outcomes according to current evidence-based best practices. This physician-led initiative formally developed 40 QIs and performance threshold targets for AP management. Validated QIs provide a dependable quantitative framework for health systems to monitor the quality of care provided to patients with known or suspected AP.
Journal Article
Endoscopic Submucosal Dissection Facilitating Techniques Among Non-experts: A Systematic Literature Review
2023
Background and AimsThe dissemination of endoscopic submucosal dissection (ESD) has been limited by its technical complexity and safety profile, particularly among non-experts. Various techniques and devices have facilitated the performance of ESD, but their yield and role in the path to learning ESD remain unclear.MethodsWe performed a systematic review by querying MEDLINE, EMBASE, Web of Science, and Japan Medical Abstracts Society specifically for comparative studies investigating the impact of assigned ESD techniques vs. conventional techniques among non-experts in ESD (< 50 ESD procedures). Procedural outcomes of efficacy, efficiency, and safety were assessed.ResultsWe identified 46 studies evaluating 54 cohorts in which a total 237 non-experts performed 2461 ESDs conventionally, and 1953 ESDs using an assigned ESD technique (knives, countertraction, miscellaneous techniques). The majority of studies were from East Asia (67%), single-center (96%), observational in design (61%), in an animal model (57%), and gastric location (63%). The most studied techniques were countertraction techniques (48% cohorts) and scissor knives (15% cohorts), both of which commonly enhanced efficiency of ESD, and less so efficacy or safety. Techniques found to be beneficial in experts were more likely to be beneficial in non-experts (70% concordance) than vice versa (47% concordance).ConclusionBased on the currently available literature, countertraction techniques and scissor knives should be considered for early incorporation into ESD training by non-experts. Several aspects of ESD training remain understudied, including techniques in Western non-experts, educational resources, and several commonly cited techniques. These areas should guide future investigation to enhance the pathway to learning ESD.
Journal Article
Use of a Novel Artificial Intelligence System Leads to the Detection of Significantly Higher Number of Adenomas During Screening and Surveillance Colonoscopy: Results From a Large, Prospective, US Multicenter, Randomized Clinical Trial
by
Iles-Shih, Lulu
,
Wright, Cindy Haden
,
Mizrahi, Meir
in
Artificial intelligence
,
Cancer
,
Clinical trials
2024
INTRODUCTION:Adenoma per colonoscopy (APC) has recently been proposed as a quality measure for colonoscopy. We evaluated the impact of a novel artificial intelligence (AI) system, compared with standard high-definition colonoscopy, for APC measurement.METHODS:This was a US-based, multicenter, prospective randomized trial examining a novel AI detection system (EW10-EC02) that enables a real-time colorectal polyp detection enabled with the colonoscope (CAD-EYE). Eligible average-risk subjects (45 years or older) undergoing screening or surveillance colonoscopy were randomized to undergo either CAD-EYE-assisted colonoscopy (CAC) or conventional colonoscopy (CC). Modified intention-to-treat analysis was performed for all patients who completed colonoscopy with the primary outcome of APC. Secondary outcomes included positive predictive value (total number of adenomas divided by total polyps removed) and adenoma detection rate.RESULTS:In modified intention-to-treat analysis, of 1,031 subjects (age: 59.1 ± 9.8 years; 49.9% male), 510 underwent CAC vs 523 underwent CC with no significant differences in age, gender, ethnicity, or colonoscopy indication between the 2 groups. CAC led to a significantly higher APC compared with CC: 0.99 ± 1.6 vs 0.85 ± 1.5, P = 0.02, incidence rate ratio 1.17 (1.03-1.33, P = 0.02) with no significant difference in the withdrawal time: 11.28 ± 4.59 minutes vs 10.8 ± 4.81 minutes; P = 0.11 between the 2 groups. Difference in positive predictive value of a polyp being an adenoma among CAC and CC was less than 10% threshold established: 48.6% vs 54%, 95% CI −9.56% to −1.48%. There were no significant differences in adenoma detection rate (46.9% vs 42.8%), advanced adenoma (6.5% vs 6.3%), sessile serrated lesion detection rate (12.9% vs 10.1%), and polyp detection rate (63.9% vs 59.3%) between the 2 groups. There was a higher polyp per colonoscopy with CAC compared with CC: 1.68 ± 2.1 vs 1.33 ± 1.8 (incidence rate ratio 1.27; 1.15-1.4; P < 0.01).DISCUSSION:Use of a novel AI detection system showed to a significantly higher number of adenomas per colonoscopy compared with conventional high-definition colonoscopy without any increase in colonoscopy withdrawal time, thus supporting the use of AI-assisted colonoscopy to improve colonoscopy quality (ClinicalTrials.gov NCT04979962).
Journal Article
Gender-Specific Factors Influencing Gastroenterologists to Pursue Careers in Advanced Endoscopy: Perceptions vs Reality
by
David, Yakira N.
,
Kim, Michelle K.
,
Kumta, Nikhil A.
in
Adult
,
Attitude of Health Personnel
,
Career Choice
2021
In 2020, only 19% of 63 matched advanced endoscopy (AE) fellows were women. This study evaluates the gender-specific factors that influence gastroenterologists to pursue careers in AE.
An anonymous survey was distributed to gastroenterology fellows and attendings through various gastroenterology society online forums. Data were collected on demographics, training, mentorship, current practice, family planning, and career satisfaction.
Women comprised 71.1% of the 332 respondents. 24.7% of female fellows plan to pursue an AE career compared with 37.5% of male fellows (P = 0.195). The main motivating factor for both genders was interest in the subject area. Interest in another subspecialty was the main deterring factor for both genders. Women were more deterred by absence of same-sex mentors (P < 0.001), perception of gender-based bias in the workplace (P = 0.009), family planning (P = 0.018), fertility/pregnancy risks from radiation (P < 0.001), and lack of ergonomic equipment (P = 0.003). AE gastroenterologists of both genders were satisfied with their career decision and would recommend the field to any fellow. Most respondents (64%) believed that more female role models/mentors would improve representation of women in AE.
There are multiple gender-specific factors that deter women from pursuing AE. Increasing the number of female role models is strongly perceived to improve representation of women in AE. Most AE attendings are satisfied with their career and would recommend it to fellows of any gender. Thus, early targeted mentorship of female trainees has potential to improve recruitment of women to the field.
Journal Article