Molecular Architectures of Trimeric SIV and HIV-1 Envelope Glycoproteins on Intact Viruses: Strain-Dependent Variation in Quaternary Structure
by
Meyerson, Joel R.
,
Nandwani, Rachna
,
de la Cruz, M. Jason V.
in
Acquired immune deficiency syndrome
,
AIDS
,
Biochemistry/Macromolecular Assemblies and Machines
2010
The initial step in target cell infection by human, and the closely related simian immunodeficiency viruses (HIV and SIV, respectively) occurs with the binding of trimeric envelope glycoproteins (Env), composed of heterodimers of the viral transmembrane glycoprotein (gp41) and surface glycoprotein (gp120) to target T-cells. Knowledge of the molecular structure of trimeric Env on intact viruses is important both for understanding the molecular mechanisms underlying virus-cell interactions and for the design of effective immunogen-based vaccines to combat HIV/AIDS. Previous analyses of intact HIV-1 BaL virions have already resulted in structures of trimeric Env in unliganded and CD4-liganded states at ~20 Å resolution. Here, we show that the molecular architectures of trimeric Env from SIVmneE11S, SIVmac239 and HIV-1 R3A strains are closely comparable to that previously determined for HIV-1 BaL, with the V1 and V2 variable loops located at the apex of the spike, close to the contact zone between virus and cell. The location of the V1/V2 loops in trimeric Env was definitively confirmed by structural analysis of HIV-1 R3A virions engineered to express Env with deletion of these loops. Strikingly, in SIV CP-MAC, a CD4-independent strain, trimeric Env is in a constitutively \"open\" conformation with gp120 trimers splayed out in a conformation similar to that seen for HIV-1 BaL Env when it is complexed with sCD4 and the CD4i antibody 17b. Our findings suggest a structural explanation for the molecular mechanism of CD4-independent viral entry and further establish that cryo-electron tomography can be used to discover distinct, functionally relevant quaternary structures of Env displayed on intact viruses.
Journal Article
Keeping 3D electron crystallography relevant: Leveraging new technologies for 3D ED/MicroED at a regional cryoEM center
2025
The crystallographic method MicroED (3D ED/MicroED) has seen a resurgence for protein structure determination since 2013, and for solving small-molecule structures since 2018. However, since the cryoEM “resolution revolution” in 2014, there has not been widespread adoption of the technique at cryoEM facilities as compared with single particle analysis. I discuss my experiences concerning the setup and use of MicroED at the New York Structural Biology Center, from 2018 to present, as well as technological advances in the cryoEM technique since then. In particular, I highlight how these improvements have guided current development and use of MicroED in multiuser facilities.
Journal Article
The collection of MicroED data for macromolecular crystallography
by
Liu, Jinyang
,
Nannenga, Brent L
,
Calero, Guillermo
in
631/45/535/1258/1259
,
631/535/1258/1260
,
631/92/612
2016
MicroED is a cryo-EM technique for collecting electron diffraction data from microcrystals and nanocrystals. This protocol from Gonen and colleagues describes how to prepare the protein crystal samples, how to set up the electron microscope for MicroED, and diffraction data collection.
The formation of large, well-ordered crystals for crystallographic experiments remains a crucial bottleneck to the structural understanding of many important biological systems. To help alleviate this problem in crystallography, we have developed the MicroED method for the collection of electron diffraction data from 3D microcrystals and nanocrystals of radiation-sensitive biological material. In this approach, liquid solutions containing protein microcrystals are deposited on carbon-coated electron microscopy grids and are vitrified by plunging them into liquid ethane. MicroED data are collected for each selected crystal using cryo-electron microscopy, in which the crystal is diffracted using very few electrons as the stage is continuously rotated. This protocol gives advice on how to identify microcrystals by light microscopy or by negative-stain electron microscopy in samples obtained from standard protein crystallization experiments. The protocol also includes information about custom-designed equipment for controlling crystal rotation and software for recording experimental parameters in diffraction image metadata. Identifying microcrystals, preparing samples and setting up the microscope for diffraction data collection take approximately half an hour for each step. Screening microcrystals for quality diffraction takes roughly an hour, and the collection of a single data set is ∼10 min in duration. Complete data sets and resulting high-resolution structures can be obtained from a single crystal or by merging data from multiple crystals.
Journal Article
Molecular mechanisms of assembly and TRIP13-mediated remodeling of the human Shieldin complex
by
Xu, Guotai
,
Xie, Wei
,
Wang, Juncheng
in
Adenosine Triphosphate - metabolism
,
ATPases Associated with Diverse Cellular Activities - chemistry
,
ATPases Associated with Diverse Cellular Activities - metabolism
2021
The Shieldin complex, composed of REV7, SHLD1, SHLD2, and SHLD3, protects DNA double-strand breaks (DSBs) to promote nonhomologous end joining. The AAA⁺ ATPase TRIP13 remodels Shieldin to regulate DNA repair pathway choice. Here we report crystal structures of human SHLD3–REV7 binary and fused SHLD2–SHLD3–REV7 ternary complexes, revealing that assembly of Shieldin requires fused SHLD2–SHLD3 induced conformational heterodimerization of open (O-REV7) and closed (C-REV7) forms of REV7. We also report the cryogenic electron microscopy (cryo-EM) structures of the ATPγS-bound fused SHLD2–SHLD3–REV7–TRIP13 complexes, uncovering the principles underlying the TRIP13-mediated disassembly mechanism of the Shieldin complex. We demonstrate that the N terminus of REV7 inserts into the central channel of TRIP13, setting the stage for pulling the unfolded N-terminal peptide of C-REV7 through the central TRIP13 hexameric channel. The primary interface involves contacts between the safety-belt segment of C-REV7 and a conserved and negatively charged loop of TRIP13. This process is mediated by ATP hydrolysis-triggered rotatory motions of the TRIP13 ATPase, thereby resulting in the disassembly of the Shieldin complex.
Journal Article
Integrative structure and functional anatomy of a nuclear pore complex
2018
Nuclear pore complexes play central roles as gatekeepers of RNA and protein transport between the cytoplasm and nucleoplasm. However, their large size and dynamic nature have impeded a full structural and functional elucidation. Here we determined the structure of the entire 552-protein nuclear pore complex of the yeast
Saccharomyces cerevisiae
at sub-nanometre precision by satisfying a wide range of data relating to the molecular arrangement of its constituents. The nuclear pore complex incorporates sturdy diagonal columns and connector cables attached to these columns, imbuing the structure with strength and flexibility. These cables also tie together all other elements of the nuclear pore complex, including membrane-interacting regions, outer rings and RNA-processing platforms. Inwardly directed anchors create a high density of transport factor-docking Phe-Gly repeats in the central channel, organized into distinct functional units. This integrative structure enables us to rationalize the architecture, transport mechanism and evolutionary origins of the nuclear pore complex.
The structure of the yeast nuclear pore complex, determined at sub-nanometre precision using an integrative approach that combines a wide range of data, reveals details of its architecture, transport mechanism and evolutionary origins.
Structure of yeast nuclear pore complex
Nuclear pore complexes (NPCs) are the gateways for the transport of RNA and proteins into and out of the nucleus. Although previous work has provided structural insights into parts of NPCs, getting a full picture of these complexes has proved difficult owing to their large size and dynamic nature. A multidisciplinary team of researchers now report the structure of the entire 552-protein NPC of the yeast at a sub-nanometre level using an integrative approach including mass spectrometry, cryo-electron tomography and chemical crosslinking. The structure provides a detailed view of the functional elements of the NPC and clarifies its architecture, mechanism of action and evolutionary origins.
Journal Article
Atomic-resolution structures from fragmented protein crystals with the cryoEM method MicroED
by
Seidler, Paul
,
Cascio, Duilio
,
Hinck, Andrew P
in
101/28
,
631/1647/2258/1258/1259
,
631/1647/2258/1266/1265
2017
Fragmentation of large, imperfect crystals into nanocrystals by sonication, vortexing, or vigorous pipetting facilitates atomic-resolution analysis by the cryo-EM method MicroED.
Traditionally, crystallographic analysis of macromolecules has depended on large, well-ordered crystals, which often require significant effort to obtain. Even sizable crystals sometimes suffer from pathologies that render them inappropriate for high-resolution structure determination. Here we show that fragmentation of large, imperfect crystals into microcrystals or nanocrystals can provide a simple path for high-resolution structure determination by the cryoEM method MicroED and potentially by serial femtosecond crystallography.
Journal Article
Atomic resolution structures from fragmented protein crystals by the cryoEM method MicroED
2017
Crystallographic analysis of macromolecules depends on large, well-ordered crystals, which often require significant effort to obtain. Even sizable crystals sometimes suffer from pathologies that render them inappropriate for high-resolution structure determination. Here we show that fragmentation of large, imperfect crystals can provide a simple path for high-resolution structure determination by serial femtosecond crystallography or the cryoEM method MicroED.
Journal Article
Structural basis for Lamassu-based antiviral immunity and its evolution from DNA repair machinery
2025
Bacterial immune systems exhibit remarkable diversity and modularity, as a consequence of the continuous selective pressures imposed by phage predation. Despite recent mechanistic advances, the evolutionary origins of many antiphage immune systems remain elusive, especially for those that encode homologs of the Structural Maintenance of Chromosomes (SMC) superfamily, which are essential for chromosome maintenance and DNA repair across domains of life. Here, we elucidate the structural basis and evolutionary emergence of Lamassu, a bacterial immune system family featuring diverse effectors but a core conserved SMC-like sensor. Using cryo-EM, we determined structures of the
Lamassu complex in both apo- and dsDNA-bound states, revealing unexpected stoichiometry and topological architectures. We further demonstrate how Lamassu specifically senses dsDNA
and phage replication origins
, thereby triggering the formation of LmuA tetramers that activate the Cap4 nuclease domain. Our findings reveal that Lamassu evolved via exaptation of the bacterial Rad50-Mre11 DNA repair system to form a compact, modular sensor for viral replication, exemplifying how cellular machinery can be co-opted for novel immune functions.
Journal Article
A method to minimize condenser lens-induced hysteresis effects in a JEOL JEM-3200FSC microscope to enable stable cryoEM low-dose operations
2017
Low dose imaging procedures are key for a successful cryoEM experiment (whether by electron cryotomography, single particle analysis, electron crystallography, or MicroED). We present a method to minimize magnetic hysteresis of the condenser lens system in the JEOL JEM-3200FSC transmission electron microscope (TEM) in order to maintain a stable optical axis for the beam path of low-dose imaging. The simple procedure involves independent voltage ramping of the CL1 and CL2 lenses immediately before switching to the focusing and exposure beam settings for data collection.