Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Series Title
      Series Title
      Clear All
      Series Title
  • Reading Level
      Reading Level
      Clear All
      Reading Level
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Content Type
    • Item Type
    • Is Full-Text Available
    • Subject
    • Country Of Publication
    • Publisher
    • Source
    • Target Audience
    • Donor
    • Language
    • Place of Publication
    • Contributors
    • Location
27 result(s) for "جودة الهواء"
Sort by:
تقييم مؤشر جودة الهواء وانعكاساته البيئية على سكان مدينة الفلوجة
يسهم التحضر السريع في زيادة تراكيز الملوثات في الهواء المحيط، وهذا ما يظهر واضحا بعد تطبيق المعادلة الخطية لمؤشر جودة الهواء في مدينة الفلوجة، إذ تراوحت قيم مؤشر جودة الهواء للدقائق العالقة الكلية بين فئة الجيد والخطر جدا (AQI= ٠- ٥٠٠) للموسمين، أما قيم مؤشر جودة الهواء للجسيمات ذات حجم (PM 2.5) فتراوحت قيم مؤشر بين فئة المعتدل إلى فئة الخطر جدا (AQl= 51- 500) لشهر كانون الثاني، في حين تراوحت قيم المؤشر بين فئة المعتدل والخطر ( = AQl51- 300) لشهر تموز، أما قيم مؤشر جودة الهواء للجسيمات ذات حجم (PM 10) فتراوحت بين المعتدل والخطر جدا (AQl = 51-500) لشهر كانون الثاني، أما شهر تموز فتراوحت قيم المؤشر بين فئة الجيد والخطر (AQl = 0-300) ومن التأثيرات الصحية التي ترافق ارتفاع قيم المؤشر انخفاض قدرة التحمل لدى الأشخاص الأصحاء وظهور أعراض سلبية للأشخاص المصابين بالحساسية، أما إذا كانت قيم المؤشر أكبر من ٥٠٠ فيمكن أن يؤدي إلى حدوث وفيات للناس المرضى وكبار السن، وتتباين قيم المؤشر تبعا لتباين الأنشطة البشرية ونوع الوقود المستعمل في مدينة الفلوجة.
Assessment of Ambient Air Quality Level at Different Areas inside Dammam University , Case Study
The air pollution problem inside university campuses has different sources, including the traffic activity inside the campus, lab works and the transportation of air pollutants from the surrounding areas and activities. The aim of this study is to assess levels of air pollutants at different areas inside the campus of University of Dammam (UD). Different air pollutants were measured including PM10, CO2, CO, SO2, NO2, O3 and VOCs. At the same time, the atmospheric temperature and relative humidity were recorded. Levels of the selected air pollutants were measured at two different durations of the day (early morning and late afternoon) during the studying and holiday periods of the academic year 201 -2012. Levels of all pollutants during the morning rush hours of the studying periods were higher than those during the other periods (holidays and afternoon periods).In addition, the highest levels of air pollutants were found at the main gate and administration building that are characterized by high traffic movement compared with the other sites inside the UD campus. These results indicated that the main source of air pollution inside UD campus is the traffic activity. The mean levels of PM10 at most selected sites were higher than the recommended air quality guidelines. تتعدد مصادر تلوث الهواء داخل الحرم الجامعي بحيث تشمل حركة السيارات و انبعاثات المعامل بالإضافة إلى انتقال الملوثات من المصادر الخارجة مثل المصانع و عمليات البناء وغيرها. ونتيجة لذلك فإن الطلاب والعاملين داخل الحرم الجامعي مع كثرة عددهم يمكن أن يتعرضوا لتزكيزات عالية مبن هذه الملوثات مما قد يؤثر سلبا على صحتهم أو كفاءة أدائهم التعليمي والإداري وتهدف هذه الدراسة إلى تقييم مستوى جودة الهواء الخارجي في مناطق مختلفة من الحرم الجامعي لجامعة الدمام. و قد تم خلال هذه الدراسة قياس تركيزات العديد من الملوثات في الهواء الخارجي داخل حرم جامعة الدمام تضمنت الجسيمات الاقل من ١٠ ميكرون حجما، و غاز ثانى أكسيد الكربون، وغاز أول أكسيد الكربون، وغاز ثاني أكسيد الكبريت، و غاز ثاني أكسيد النيتروجين، وغاز الأوزون، و أبخرة المركبات العضوية المتطايرة. إضافة إلى ذلك، فقد سجلت درجة الحرارة و الرطوبة النسبية تزامنا مع وقت أخذ العينات ملوثات الهواء. و قد تم قياس مستويات ملوثات الهواء المختارة في فترتين مختلفتين من اليوم الدراسي (الصباح الباكر وبعد الظهر) و ذلك خلال فترات الدراسة والعطلات الدراسية للعام الدراسي 2011-2012. و قد أظهرت نتائج الدراسة أن مستويات جميع الملوثات خلال ساعات الذروة الصباحية لفترات الدراسة أعلى من غيرها في الفترات الأخرى (العطلات وفترات بعد الظهر). و بالإضافة إلى ذلك، فقد سجلت أعلى مستويات لملوثات الهواء عند البوابة الرئيسية ومبنى الإدارة الرئيسي. و تتميز هذه المواقع بوجود حركة مرور عالية مقارنة مع المواقع الأخرى داخل الحرم الجامعي، فضلا على أنها تقع بالقرب من الطريق الرئيسي المروري خارج الحرم الجامعي. و قد أثبتت هذه النتائج أن المصدر الرئيسي لتلوث الهواء داخل حرم جامعة الدمام هو نشاط الحركة المرورية للسيارات .وكانت معظم مستويات الجسيمات الاقل من 10ميكرون حجما في معظم مواقع مختارة أعلى من الحدود الامنة المقررة لنوعية الهواء الجيد في قوانين البيئة.
Ambient Air Quality Measurement in Al-Asmarat Discrete, Al Muqatam, Cairo, Egypt
The ambient air pollution of Al-Asmarat discrete, Al-Muqatam, Cairo, Egypt was measured on a 24 hours basis at one sampling station during the summer of 2018 by collecting samples of carbon monoxide (CO), sulfur dioxides (SO₂), hydrogen sulfide (H₂S), nitrogen oxides (NO₂), ozone (O₃) and particulate matters PM (2.5&10) at 15/16 July 2018 and 2/3 August 2018. Temperature and humidity were also measured. Major contributors to those pollutants were due to mobile vehicles and open burning emissions of Al Wafaawa Al Amal dump. We found that the mean concentrations of the air pollutants at the first measurement 15/7 for CO, SO₂, H₂S, NO₂, O₃ and PM (10&2.5) were 0.928 mg/m³, 42.86μg/m³, 151μg/m³, 69.8μg/m³, 21.4μg/m³, and (52.35&62.71mg/m³), respectively. While the concentration at the second measurement 2/8 were 1.10mg/m3, 196.1μg/m3, 252μg/m3, 21.2μg/m3 and (39.9&46.7 μg/m3), respectively. In conclusion, air pollutant concentrations in Al-Asmarat are lower except for SO₂ and H₂S. The mean H₂S concentration was 40 times the World Health Organization (WHO) cut-off limits and the mean SO₂ concentration was more than WHO guidelines and the Egyptian law No.4, while NO₂, NO, O₃ and PM (10&2.5) concentrations are below WHO guidelines and the Egyptian law No.4. Long-term studies are needed to characterize air pollution levels during all seasons, to assess related public health impacts, and explore mitigation approaches.
Computational Investigation for the Windcatcher Top Roof Length Effect on Indoor Air Quality
The main aim of the current research is to calculate the optimum top roof length of wind catcher for enhancing indoor air quality (IAQ) parameters such as (AAV) average air velocity, (AFR) air flow rate, (ACR)air change rate, (MAA) mean age of air and (ACE) air change effectiveness. This work assesses the effect of the top roof length of wind catcher on indoor natural ventilation in a tropical climate or dense urban areas. The research method was conducted through Autodesk CFD 2019 software for simulation purposes. The reference tested model is composed of a rectangular cuboid with 8 m length, 6 m width and 3 m height which represents a small model room for applying the numerical simulation and the wind catcher was combined with the room roof. The tested windcatcher form is a rectangular cuboid of 1.4 m length, 1 m width and 1.5 m height, while the inlet and outlet openings of the wind catcher are 1 m by 1 m. The wind catcher simulation is aimed to determine the IAQ parameters for different 11 case studies with different top roof projection length ranges from 0 cm to 100 cm with an interval each 10 cm. The main results of these CFD simulations are representing the effect of the projection length of top roof of wind catcher on the parameters of natural ventilation performance. Based on the simulation, it can be concluded that the increasing of the top roof of wind catcher to 100 cm leads to increase in the AAV with 10.5%, increase AFR with 190%, increase ACH with 11% at inlet. Also increase AVA with 14%, decrease MAA with 14% and increase ACE with 67% inside the tested model. Depending on the results, this paper suggests a regression equation that can predict the inlet and indoor average air velocity for different projection lengths for the tested model.
جودة التهوية الطبيعية على البيئة السكنية بحي الدقي
يتناول البحث دراسة جودة التهوية الطبيعية على البيئة السكنية، ويتألف من تشكيلة عناصر أبرزها الشوارع والكتلة المبنية وتفاعلها مع الرياح واتجاهتها المكونة للتهوية الطبيعية لإضفاء أنماط من جودة التهوية تختلف من منطقة لأخرى، وتحدد نوعية البيئة السكنية فيما يتعلق بإمكانية التهوية الطبيعية. وتم تسليط الضوء على مورفولوجية المنطقة، من خلال دراسة توزيع المباني ومساحتها ومستوى الكثافة البنائية وارتفاعات المباني، ثم الوقوف على دراسة شبكة الطرق والشوارع كأداة فاعلة في تحديد كفاءة النسيج العمراني لما لها من أهمية بالغة، لكونها أدوات فصل ووصل بين قطع النسيج العمراني. وستركز الدراسة أيضا على مدى التوافق بين هبوب الرياح واتجاهات الشوارع كما يتم إلقاء الضوء على مدى الجودة في التوافق بين هبوب الرياح واتجاهات الشوارع ودراسة تقييم أثر خصائص الشوارع على التهوية ومدى جودة التهوية الطبيعية بالشارع، وينتهي هذا البحث بتحليل جودة التهوية الطبيعية من منظور الخصائص العمرانية بمنطقة الدراسة واختتمت بالنتائج والتوصيات.
الرياح وجودة الهواء بوسط الدلتا المصرية خلال الفترة من 2018-2019 م
يتطلب حماية البيئة والتخطيط لخدمة التنمية المستدامة وصيانة الموارد البيئية دراسة جودة الهواء كأحد أهم متطلبات الحفاظ على الصحة العامة للسكان، لذلك تم دراسة وتقييم جودة الهواء بمنطقة الدراسة من خلال معرفة مؤشر جودة الهواء بمنطقة الدراسة حيث تقع وسط الدلتا في نطاق المنطقة المعتدلة (100:51) تبعا لمؤشر جودة الهواء التابع لوكالة حماية الأمريكية، عدا منطقة طنطا التي تقع ضمن نطاق غير الصحي للأفراد التي تعاني من الحساسية (150:101).