Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
1 result(s) for "AMS-ICP-MS (All-Matrix sampling ICP-MS)"
Sort by:
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
This study presents a rapid and highly sensitive method for the determination of trace rubidium (Rb) and cesium (Cs) in high-salinity brines using inductively coupled plasma mass spectrometry (ICP-MS) equipped with an all-matrix sampling (AMS) device. The AMS system achieves online gas dilution by vertically introducing argon gas into the brine sample flow, effectively reducing the severe matrix suppression effect caused by 35 g·L −1 salinity to an intermediate level. Experimental results demonstrated that the signal suppression induced by coexisting cations (K + , Na + , Ca 2+ , Mg 2+ ) in actual brine samples was minimal (< 1.5%), thereby eliminating the need for conventional matrix matching or standard addition approaches. Accurate quantification was achieved through a straightforward calibration process based on standard curves (Rb: 5–400 μg·L −1 ; Cs: 5–400 μg·L −1 ; R 2  > 0.999), enhanced by dynamic internal standard correction using yttrium (Y) and rhodium (Rh), along with optimized instrument parameters (RF power and nebulizer gas flow rate). The method demonstrates excellent limits of detection (LOD: 0.039 μg·L −1 for Rb; 0.005 μg·L −1 for Cs), high precision (RSD < 5%), and acceptable recovery rates (85%–108%). The accuracy was further validated through comparison with AAS standard addition for high-concentration samples (> 200 μg·L −1 ), yielding consistent recoveries (98.6% –114%) and inter-method deviations ≤ 12.2%. Additionally, the simplification of the sample pretreatment procedure—from a traditional multi-step dilution to a single-step dilution without acid-washed containers—enhances analytical efficiency by over 70%. This approach provides a robust, sensitive, and operationally efficient solution for the analysis of extreme high-salinity environmental samples.