MbrlCatalogueTitleDetail

Do you wish to reserve the book?
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device
Journal Article

A rapid method for detecting trace Rb and Cs in high-salinity brines by ICP-MS equipped with an all-matrix sampling device

2025
Request Book From Autostore and Choose the Collection Method
Overview
This study presents a rapid and highly sensitive method for the determination of trace rubidium (Rb) and cesium (Cs) in high-salinity brines using inductively coupled plasma mass spectrometry (ICP-MS) equipped with an all-matrix sampling (AMS) device. The AMS system achieves online gas dilution by vertically introducing argon gas into the brine sample flow, effectively reducing the severe matrix suppression effect caused by 35 g·L −1 salinity to an intermediate level. Experimental results demonstrated that the signal suppression induced by coexisting cations (K + , Na + , Ca 2+ , Mg 2+ ) in actual brine samples was minimal (< 1.5%), thereby eliminating the need for conventional matrix matching or standard addition approaches. Accurate quantification was achieved through a straightforward calibration process based on standard curves (Rb: 5–400 μg·L −1 ; Cs: 5–400 μg·L −1 ; R 2  > 0.999), enhanced by dynamic internal standard correction using yttrium (Y) and rhodium (Rh), along with optimized instrument parameters (RF power and nebulizer gas flow rate). The method demonstrates excellent limits of detection (LOD: 0.039 μg·L −1 for Rb; 0.005 μg·L −1 for Cs), high precision (RSD < 5%), and acceptable recovery rates (85%–108%). The accuracy was further validated through comparison with AAS standard addition for high-concentration samples (> 200 μg·L −1 ), yielding consistent recoveries (98.6% –114%) and inter-method deviations ≤ 12.2%. Additionally, the simplification of the sample pretreatment procedure—from a traditional multi-step dilution to a single-step dilution without acid-washed containers—enhances analytical efficiency by over 70%. This approach provides a robust, sensitive, and operationally efficient solution for the analysis of extreme high-salinity environmental samples.