Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
2,516 result(s) for "Analytical validation"
Sort by:
Development and Validation of Two Diagnostic Real-Time PCR (TaqMan) Assays for the Detection of Bordetella avium from Clinical Samples and Comparison to the Currently Available Real-Time TaqMan PCR Assay
Bordetella avium (BA) is one of many pathogens that cause respiratory diseases in turkeys. However, other bacterial species can easily overgrow it during isolation attempts. This makes confirming the diagnosis of BA as the causative agent of turkey coryza more difficult. Currently, there are two PCR assays for the molecular detection of BA. One is conventional gel-based PCR and the other is TaqMan real-time PCR (qPCR) assay. However, multiple pitfalls were detected in both assays regarding their specificity, sensitivity, and efficiency, which limits their utility as diagnostic tools. In this study, we developed and validated two TaqMan qPCR assays and compared their performance to the currently available TaqMan qPCR. The two assays were able to correctly identify all BA isolates and showed negative results against a wide range of different microorganisms. The two assays were found to have high efficiency with a detection limit of approximately 1 × 103 plasmid DNA Copies/mL with high repeatability and reproducibility. In comparison to the currently available TaqMan qPCR assay, the newly developed assays showed significantly higher PCR efficiencies due to superior primers and probes design. The new assays can serve as a reliable tool for the sensitive, specific, and efficient diagnosis of BA.
Clinical and analytical comparison of six Simoa assays for plasma P-tau isoforms P-tau181, P-tau217, and P-tau231
Introduction Studies using different assays and technologies showed highly promising diagnostic value of plasma phosphorylated (P-)tau levels for Alzheimer’s disease (AD). We aimed to compare six P-tau Simoa assays, including three P-tau181 (Eli Lilly, ADx, Quanterix), one P-tau217 (Eli Lilly), and two P-tau231 (ADx, Gothenburg). Methods We studied the analytical (sensitivity, precision, parallelism, dilution linearity, and recovery) and clinical (40 AD dementia patients, age 66±8years, 50%F; 40 age- and sex-matched controls) performance of the assays. Results All assays showed robust analytical performance, and particularly P-tau217 Eli Lilly; P-tau231 Gothenburg and all P-tau181 assays showed robust clinical performance to differentiate AD from controls, with AUCs 0.936–0.995 (P-tau231 ADx: AUC = 0.719). Results obtained with all P-tau181 assays, P-tau217 Eli Lilly assay, and P-tau231 Gothenburg assay strongly correlated (Spearman’s rho > 0.86), while correlations with P-tau231 ADx results were moderate (rho < 0.65). Discussion P-tau isoforms can be measured robustly by several novel high-sensitive Simoa assays.
Generic Protocols for the Analytical Validation of Next-Generation Sequencing-Based ctDNA Assays: A Joint Consensus Recommendation of the BloodPAC’s Analytical Variables Working Group
Abstract Liquid biopsy, particularly the analysis of circulating tumor DNA (ctDNA), has demonstrated considerable promise for numerous clinical intended uses. Successful validation and commercialization of novel ctDNA tests have the potential to improve the outcomes of patients with cancer. The goal of the Blood Profiling Atlas Consortium (BloodPAC) is to accelerate the development and validation of liquid biopsy assays that will be introduced into the clinic. To accomplish this goal, the BloodPAC conducts research in the following areas: Data Collection and Analysis within the BloodPAC Data Commons; Preanalytical Variables; Analytical Variables; Patient Context Variables; and Reimbursement. In this document, the BloodPAC’s Analytical Variables Working Group (AV WG) attempts to define a set of generic analytical validation protocols tailored for ctDNA-based Next-Generation Sequencing (NGS) assays. Analytical validation of ctDNA assays poses several unique challenges that primarily arise from the fact that very few tumor-derived DNA molecules may be present in circulation relative to the amount of nontumor-derived cell-free DNA (cfDNA). These challenges include the exquisite level of sensitivity and specificity needed to detect ctDNA, the potential for false negatives in detecting these rare molecules, and the increased reliance on contrived samples to attain sufficient ctDNA for analytical validation. By addressing these unique challenges, the BloodPAC hopes to expedite sponsors’ presubmission discussions with the Food and Drug Administration (FDA) with the protocols presented herein. By sharing best practices with the broader community, this work may also save the time and capacity of FDA reviewers through increased efficiency.
Analytical and Clinical Validation of Assays for Volumetric Absorptive Microsampling (VAMS) of Drugs in Different Blood Matrices: A Literature Review
Volumetric absorptive microsampling (VAMS) is the newest and most promising sample-collection technique for quantitatively analyzing drugs, especially for routine therapeutic drug monitoring (TDM) and pharmacokinetic studies. This technique uses an absorbent white tip to absorb a fixed volume of a sample (10–50 µL) within a few seconds (2–4 s), is more flexible, practical, and more straightforward to be applied in the field, and is probably more cost-effective than conventional venous sampling (CVS). After optimization and validation of an analytical method of a drug taken by VAMS, a clinical validation study is needed to show that the results by VAMS can substitute what is gained from CVS and to justify implementation in routine practice. This narrative review aimed to assess and present studies about optimization and analytical validation of assays for drugs taken by VAMS, considering their physicochemical drug properties, extraction conditions, validation results, and studies on clinical validation of VAMS compared to CVS. The review revealed that the bio-analysis of many drugs taken with the VAMS technique was optimized and validated. However, only a few clinical validation studies have been performed so far. All drugs that underwent a clinical validation study demonstrated good agreement between the two techniques (VAMS and CVS), but only by Bland–Altman analysis. Only for tacrolimus and mycophenolic acid were three measurements of agreement evaluated. Therefore, VAMS can be considered an alternative to CVS in routine practice, especially for tacrolimus and mycophenolic acid. Still, more extensive clinical validation studies need to be performed for other drugs.
Paper Spray Tandem Mass Spectrometry Based on Molecularly Imprinted Polymer Substrate for Cocaine Analysis in Oral Fluid
This study proposes a new direct and fast method of analysis employing paper spray mass spectrometry (PS-MS). The paper used in the proposed method was modified with molecularly imprinted polymers (MIP) to create a specific site for cocaine analysis in oral fluid. MIP membrane was successfully synthetized and employed. The developed method showed to be linear in a concentration range from LOQ to 100 ng mL –1 . The experimental value of LOQ obtained was 1 ng mL –1 . The inter-day and intra-day precision and accuracy of the PS-MS method presented values lower than 15%. The total recoveries were also evaluated. The PS-MS method for the analysis of cocaine in oral fluid showed to be very promising and the validation parameters showed a good correlation with the literature. Graphical abstract ᅟ
Analytical validation of the PAM50-based Prosigna Breast Cancer Prognostic Gene Signature Assay and nCounter Analysis System using formalin-fixed paraffin-embedded breast tumor specimens
Background NanoString’s Prosigna™ Breast Cancer Prognostic Gene Signature Assay is based on the PAM50 gene expression signature. The test outputs a risk of recurrence (ROR) score, risk category, and intrinsic subtype (Luminal A/B, HER2-enriched, Basal-like). The studies described here were designed to validate the analytical performance of the test on the nCounter Analysis System across multiple laboratories. Methods Analytical precision was measured by testing five breast tumor RNA samples across 3 sites. Reproducibility was measured by testing replicate tissue sections from 43 FFPE breast tumor blocks across 3 sites following independent pathology review at each site. The RNA input range was validated by comparing assay results at the extremes of the specified range to the nominal RNA input level. Interference was evaluated by including non-tumor tissue into the test. Results The measured standard deviation (SD) was less than 1 ROR unit within the analytical precision study and the measured total SD was 2.9 ROR units within the reproducibility study. The ROR scores for RNA inputs at the extremes of the range were the same as those at the nominal input level. Assay results were stable in the presence of moderate amounts of surrounding non-tumor tissue (<70% by area). Conclusions The analytical performance of NanoString’s Prosigna assay has been validated using FFPE breast tumor specimens across multiple clinical testing laboratories.
Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening
Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. Graphical Abstract ᅟ
Intra-Individual Variability of Urinary EGF and Clusterin, and Effect of Frozen Storage on Stability: Results from UVALID
Urinary epidermal growth factor (uEGF) and clusterin (uCLU) are emerging biomarkers in chronic kidney disease (CKD), but rigorous analytical validation is required before clinical implementation. We evaluated intra-individual variability and long-term storage stability of uEGF and uCLU in CKD. In the prospective, multicenter UVALID study, 60 adults with CKD stages 2–4 underwent urine sampling at three visits over 8 weeks. First-morning and 24-h urine samples were collected to assess intra-individual variability over 24 h, 3 days and 8 weeks. Biomarkers were measured in duplicate by ELISA and normalized to urinary creatinine (/Cr). Inter-laboratory performance was assessed using quality control samples. Stability after 12 and 15 months of storage at −20 °C and −80 °C and the influence of pH were evaluated. Over 24 h, 3 days, and 8 weeks, uEGF/Cr demonstrated low variability and remained stable after long-term storage at both temperatures. In contrast, uCLU/Cr showed greater variability and pronounced instability at −20 °C, whereas stability was preserved at −80 °C. Samples with pH > 6 partially preserved uCLU stability at −20 °C. Inter-laboratory reproducibility was acceptable for uEGF but suboptimal for uCLU at low concentrations. Thus, uEGF showed robust analytical performance, supporting its potential clinical applicability in CKD, whereas uCLU exhibited important analytical and pre-analytical limitations, warranting further assay optimization. These findings underscore the need for rigorous validation to facilitate biomarker implementation in clinical practice.
Plasma brain-derived tau: analytical and clinical validation of the first commercial immunoassay
Brain-derived tau (BD-tau) is a promising blood-based biomarker for neurodegeneration/brain injury in neurodegenerative and acute neurological disorders. However, widespread use is hampered by lack of commercial assays. Using the Simoa® HD-X analyzer, we evaluated the first commercial research-use only BD-tau Advantage PLUS assay’s robustness, precision, spike recovery, specificity, dilution linearity, and limit of detection. Matrix effect was examined by comparing BD-tau levels in n = 48 plasma/serum and n = 20 plasma/CSF sample pairs. Clinical performance was examined in a traumatic brain injury (TBI) cohort. Twenty repeated measurements of three plasma samples gave intra- and inter-plate coefficient of variation (CV) ≤ 7.24%. Analytically, BD-tau concentrations decreased linearly up to 16-fold dilution, spike recovery was 86–96%, and signals were highly specific to the CNS-abundant recombinant tau-441 but not the peripherally-enriched “big-tau” isoform. Moreover, signals were stable for up to four freeze/thaw cycles. Furthermore, there were significant correlations between plasma/serum (r = 0.8392; p < 0.0001) and plasma/CSF (r = 0.6150; p = 0.0039) pairs. Finally, plasma BD-tau was elevated in severe-acute TBI vs. chronic-mixed TBI and unaffected controls (p < 0.0001; AUC = 0.9986, and p < 0.0001; AUC = 1.000, respectively). In severe-acute TBI patients, plasma BD-tau was correlated with plasma p-tau217 (r = 0.5761, p = 0.0005), NfL (r = 0.8910, p = 0.0001), and GFAP (r = 0.5424, p = 0.0011). CSF BD-tau and CSF p-tau217 were strongly correlated (r = 0.9667, p = 0.0002). BD-tau Advantage PLUS produces robust brain-derived tau-specific readings that demonstrate utility in detecting severe-acute TBI.
Analytical and Clinical Considerations in Implementing the Roche Elecsys Troponin T Gen 5 STAT Assay
Abstract Objectives To evaluate the analytical and clinical performance characteristics of the fifth-generation troponin T reagent. Methods Troponin T was measured in 2,332 paired serum and plasma samples from emergency department and hospital patients using the fourth- and fifth-generation reagents. Testing was repeated after recentrifugation to determine the frequency of analytical outliers and percentage of patients with elevated values for each assay. We conducted separate experiments to determine the effects of biotin and hemolysis interference, as well as measure interinstrument variability, for fifth-generation troponin T. Results Analytic outliers occurred more frequently using the fifth-generation reagent (3.4%) compared with the fourth-generation reagent (1.0%). The frequency of elevated troponin T above the 99th percentile upper reference limit was 26% for the fourth-generation reagent and 52% for the fifth-generation reagent. Clinically significant assay interference by biotin was observed at 20 ng/mL, but hemolysis interference was not observed until an H index of 150. Instrument-to-instrument variability between e411 and e601/602 instrument platforms is predicted to confound clinical interpretation of troponin changes. Conclusions Analytical outliers and instrument-to-instrument variability are the two analytical variables most likely to confound interpretation of changes in fifth-generation troponin T results over time.