Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
54
result(s) for
"Cherenkov light"
Sort by:
NUV-Sensitive Silicon Photomultiplier Technologies Developed at Fondazione Bruno Kessler
by
Piemonte, Claudio
,
Gola, Alberto
,
Regazzoni, Veronica
in
Cherenkov light detection
,
cryogenic SiPM
,
liquid
2019
Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm2. Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD–LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD–Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm2. Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.
Journal Article
Psoralen as a Photosensitizers for Photodynamic Therapy by Means of In Vitro Cherenkov Light
by
Runge, Roswitha
,
Hübinger, Lisa
,
Brogsitter, Claudia
in
Chemical bonds
,
Coumarins
,
Dimethyl sulfoxide
2022
Possible enhancements of DNA damage with light of different wavelengths and ionizing radiation (Rhenium-188—a high energy beta emitter (Re-188)) on plasmid DNA and FaDu cells via psoralen were investigated. The biophysical experimental setup could also be used to investigate additional DNA damage due to photodynamic effects, resulting from Cherenkov light. Conformational changes of plasmid DNA due to DNA damage were detected and quantified by gel electrophoresis and fluorescent staining. The clonogene survival of the FaDu cells was analyzed with colony formation assays. Dimethyl sulfoxide was chosen as a chemical modulator, and Re-188 was used to evaluate the radiotoxicity and light (UVC: λ = 254 nm and UVA: λ = 366 nm) to determine the phototoxicity. Psoralen did not show chemotoxic effects on the plasmid DNA or FaDu cells. After additional treatment with light (only 366 nm—not seen with 254 nm), a concentration-dependent increase in single strand breaks (SSBs) was visible, resulting in a decrease in the survival fraction due to the photochemical activation of psoralen. Whilst UVC light was phototoxic, UVA light did not conclude in DNA strand breaks. Re-188 showed typical radiotoxic effects with SSBs, double strand breaks, and an overall reduced cell survival for both the plasmid DNA and FaDu cells. While psoralen and UVA light showed an increased toxicity on plasmid DNA and human cancer cells, Re-188, in combination with psoralen, did not provoke additional DNA damage via Cherenkov light.
Journal Article
Investigation of Photodynamic Therapy Promoted by Cherenkov Light Activated Photosensitizers—New Aspects and Revelations
2024
This work investigates the proposed enhanced efficacy of photodynamic therapy (PDT) by activating photosensitizers (PSs) with Cherenkov light (CL). The approaches of Yoon et al. to test the effect of CL with external radiation were taken up and refined. The results were used to transfer the applied scheme from external radiation therapy to radionuclide therapy in nuclear medicine. Here, the CL for the activation of the PSs (psoralen and trioxsalen) is generated by the ionizing radiation from rhenium-188 (a high-energy beta-emitter, Re-188). In vitro cell survival studies were performed on FaDu, B16 and 4T1 cells. A characterization of the PSs (absorbance measurement and gel electrophoresis) and the CL produced by Re-188 (luminescence measurement) was performed as well as a comparison of clonogenic assays with and without PSs. The methods of Yoon et al. were reproduced with a beam line at our facility to validate their results. In our studies with different concentrations of PS and considering the negative controls without PS, the statements of Yoon et al. regarding the positive effect of CL could not be confirmed. There are slight differences in survival fractions, but they are not significant when considering the differences in the controls. Gel electrophoresis showed a dominance of trioxsalen over psoralen in conclusion of single and double strand breaks in plasmid DNA, suggesting a superiority of trioxsalen as a PS (when irradiated with UVA). In addition, absorption measurements showed that these PSs do not need to be shielded from ambient light during the experiment. An observational test setup for a PDT nuclear medicine approach was found. The CL spectrum of Re-188 was measured. Fluctuating inconclusive results from clonogenic assays were found.
Journal Article
A Configurable 64-Channel ASIC for Cherenkov Radiation Detection from Space
by
Di Salvo, Andrea
,
Mignone, Marco
,
Palmieri, Pietro Antonio
in
Analog to digital converters
,
Application specific integrated circuits
,
ASIC
2023
This work presents the development of a 64-channel application-specific integrated circuit (ASIC), implemented to detect the optical Cherenkov light from sub-orbital and orbital altitudes. These kinds of signals are generated by ultra-high energy cosmic rays (UHECRs) and cosmic neutrinos (CNs). The purpose of this front-end electronics is to provide a readout unit for a matrix of silicon photo-multipliers (SiPMs) to identify extensive air showers (EASs). Each event can be stored into a configurable array of 256 cells where the on-board digitization can take place with a programmable 12-bits Wilkinson analog-to-digital converter (ADC). The sampling, the conversion process, and the main digital logic of the ASIC run at 200 MHz, while the readout is managed by dedicated serializers operating at 400 MHz in double data rate (DDR). The chip is designed in a commercial 65 nm CMOS technology, ensuring a high configurability by selecting the partition of the channels, the resolution in the interval 8–12 bits, and the source of its trigger. The production and testing of the ASIC is planned for the forthcoming months.
Journal Article
Increase in the intensity of an optical signal with fluorescein during proton and carbon‐ion irradiation
2021
Purpose Although the imaging of luminescence emitted in water during irradiation of protons and carbon ions is a useful method for range and dose estimations, the intensity of the images is relatively low due to the low photon production of the luminescence phenomenon. Therefore, a relatively long time is required for the imaging. Since a fluorescent dye, fluorescein, may increase the intensity of the optical signal, we measured the luminescence images of water with different concentrations of fluorescein during irradiation of protons and carbon ions and compared the results with those by measurements with water. Methods A cooled charge‐coupled device (CCD) camera was used for imaging a water phantom with different concentrations of fluorescein from 0.0063 to 0.025 mg/cm3, in addition to a water phantom without fluorescein during irradiation of 150‐MeV protons and 241.5‐MeV/n carbon ions. Results For both protons and carbon ions, the intensity of the luminescence images increased as the concentration of fluorescein increased. With a fluorescein concentration of 0.025 mg/cm3, the intensities increased to more than 10 times those of water for both protons and carbon ions. Although the shape of the depth profiles of luminescence images of water with fluorescein appeared similar to that of water for protons, those for carbon ions were different from those of water due to the increase in the Cherenkov light component at shallow depths by the decrease in the angular dependencies of the Cherenkov light. Conclusion We confirmed the increase in intensity of the luminescence of water by adding fluorescein for particle ions. With a small amount of Cherenkov light contamination in the images, such as protons, the relative distributions of the luminescence images with fluorescein were similar to that of water and will be used for range or dose determination in a short time.
Journal Article
EAS Observation Conditions in the SPHERE-2 Balloon Experiment
2022
The SPHERE project studies primary cosmic rays by detection of the Cherenkov light of extensive air showers reflected from the snow covered surface of the earth. Measurements with the aerial-based detector SPHERE-2 were performed in 2011–2013. The detector was lifted by a balloon to altitudes of up to 900 m above the snow covered surface of Lake Baikal, Russia. The results of the experiment are summarized now in a series of papers that opens with this article. An overview of the SPHERE-2 detector telemetry monitoring systems is presented along with the analysis of the measurements conditions including atmosphere profile. The analysis of the detector state and environment atmosphere conditions monitoring provided various cross-checks of detector calibration, positioning, and performance.
Journal Article
Parametric analysis of the Lateral Distribution Function of Cherenkov light for Yakutsk EAS Array in the Energy Range 1-20 PeV
by
Hariharan, B.
,
Al-Rubaiee, A. A.
,
Al-Zubaidi, Falah
in
Arrays
,
Cerenkov radiation
,
Cherenkov light
2020
In this research, the simulation of lateral distribution function (LDF) of Cherenkov radiation was performed using CORSIKA software for two hadronic models QGSJET and GHEISHA. This simulation was performed for several elementary particles such as protons, iron nuclei, electrons and gamma quanta, in the range of energies 1-20 PeV for three zenith angles 0°, 20° and 30°. A parameterization of Cherenkov light LDF was performed for that simulated curves using Lorentzian function. The comparison between the obtained results for LDF of Cherenkov light with that measured with Yakutsk EAS array gave a good agreement within the distances of 100-1000 m from the shower axis.
Journal Article
Energy Resolution Studies in Simulation for the IDEA Dual-Readout Calorimeter Prototype
2022
Precision measurements of Z, W, and H decays at the next generation of circular lepton colliders will require excellent energy resolution for both electromagnetic and hadronic showers. The resolution is limited by event-to-event fluctuations in the shower development, especially in the hadronic system. Compensating for this effect can greatly improve the achievable energy resolution. Furthermore, the resolution can benefit greatly from the use of particle-flow algorithms, which requires the calorimeters to have a high granularity. The approach of dual-readout calorimetry has emerged as a candidate to fulfil both of these requirements by allowing to reconstruct the fluctuations in the shower development event-by-event and offering a high transverse granularity. An important benchmark of such a calorimeter is the electromagnetic energy resolution; a prototype of the IDEA calorimeter has been built for use in testbeams. In parallel, a simulation of this prototype has been developed in Geant4 for a testbeam environment. Here, we outline how this simulation was used to study the electromagnetic energy resolution and conclude that a resolution of 14%/E is achievable.
Journal Article
Reactor Pulse Operation for Nuclear Instrumentation Detector Testing – Preparation of a Dedicated Experimental Campaign at the JSI TRIGA Reactor
by
Radulović, Vladimir
,
De Izarra, Grégoire
,
Lengar, Igor
in
activation dosimetry
,
Chambers
,
cherenkov light
2021
The availability of neutron fields with a high neutron flux, suitable for irradiation testing of nuclear instrumentation detectors relevant for applications in nuclear facilities such as material testing reactors (MTRs), nuclear power reactors and future fusion reactors is becoming increasingly limited. Over the last several years there has been increased interest in the experimental capabilities of the 250 kW Jožef Stefan Institute (JSI) TRIGA research reactor for such applications, however, the maximal achievable neutron flux in steady-state operation mode falls short of MTR-relevant conditions. The JSI TRIGA reactor can also operate in pulse mode, with a maximal achievable peak power of approximately 1 GW, for a duration of a few ms. A collaboration project between the JSI and the French Atomic and Alternative Energy Commission (CEA) was initiated to investigate absolute neutron flux measurements at very high neutron flux levels in reactor pulse operation. Such measurements will be made possible by special CEA-developed miniature fission chambers and modern data acquisition systems, supported by the JSI TRIGA instrumentation and activation dosimetry. Additionally, measurements of the intensity of Cherenkov light are proposed and being investigated as an alternative experimental method. This paper presents the preparatory activities for an exhaustive experimental campaign, which were carried out in 2019-2020, consisting of test measurements with not fully appropriate fission chambers, activation dosimetry and silicon photomultipliers (SiPMs) The presented results provide useful and promising experimental indications relevant for the design of the experimental campaign.
Journal Article
Radioluminescence by synchrotron radiation with lower energy than the Cherenkov light threshold in water
by
Hirano, Yoshiyuki
,
Onoda, Daichi
,
Nagae, Takayuki
in
Cherenkov light
,
dose measurement
,
Geant4
2020
Radioluminescence by protons and carbon ions of energy lower than the Cherenkov threshold (∼260 keV) in water has been observed. However, the origin of the luminescence has not been investigated well. In the present work, we imaged radioluminescence in water using synchrotron radiation that was of sufficiently lower energy (11 keV) than the Cherenkov threshold and we measured its spectrum using a high-sensitivity cooled CCD camera and optical longpass filters having 5 different thresholds. In addition, to determine effects of impurities in water, the water target was changed from ultrapure water to tap water. Monte Carlo simulation (Geant4) was also performed to compare its results with the experimentally obtained radioluminescence distribution. In the simulation, photons were generated in proportion to the energy deposition in water. As a result, the beam trajectory was clearly imaged by the radioluminescence in water. The spectrum was proportional to λ−3.4 0.4 under an assumption of no peaks. In the spectrum and distribution, no differences were observed between ultrapure water and tap water. TOC (total organic carbon) contents of ultrapure water and tap water as an impurity were measured and these were 0.26 mg l−1 and 2.3 mg l−1, respectively. The radioluminescence seemed to be attributable to water molecules not impurities. The radioluminescence distribution of the simulation was consistent with the experimental distribution and this suggested that radioluminescence was proportional to dose, which is expected to allow use for dose measurement.
Journal Article