Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
2,624 result(s) for "Electroencephalogram"
Sort by:
Aperiodic brain activity and response to anesthesia vary in disorders of consciousness
•Aperiodic EEG, but not oscillation, correlates with level of consciousness.•Anesthesia steepens the EEG spectral slope across disorders of consciousness.•Changes in EEG spectral slope reflect pre-anesthetic level of responsiveness.•Changes in the aperiodic EEG accompany loss of signal complexity and criticality. In the human electroencephalogram (EEG), oscillatory power co-exist with non-oscillatory, aperiodic activity. Although EEG analysis has traditionally focused exclusively on oscillatory power, recent investigations have shown that the aperiodic EEG component can distinguish conscious wakefulness from sleep and anesthetic-induced unconsciousness. This study investigates the aperiodic EEG component of individuals in a disorder of consciousness (DOC); how it changes in response to exposure to anesthesia; and how it relates to the brain's information richness and criticality. High-density EEG was recorded from 43 individuals in a DOC, with 16 of these individuals undergoing a protocol of propofol anesthesia. The aperiodic component was defined by the spectral slope of the power spectral density. Our results demonstrate that the EEG aperiodic component is more informative about the participants’ level of consciousness than the oscillatory component, especially for patients that suffered from a stroke. Importantly, the pharmacologically induced change in the spectral slope from 30 to 45 Hz positively correlated with individual's pre-anesthetic level of consciousness. The pharmacologically induced loss of information-richness and criticality was associated with individual's pre-anesthetic aperiodic component. During exposure to anesthesia, the aperiodic component distinguished individuals with DOC, according to their 3-month recovery status. The aperiodic EEG component has been historically neglected; this research highlights the necessity of considering this measure for the assessment of individuals in DOC and future research that seeks to understand the neurophysiological underpinnings of consciousness. [Display omitted]
Autoreject: Automated artifact rejection for MEG and EEG data
We present an automated algorithm for unified rejection and repair of bad trials in magnetoencephalography (MEG) and electroencephalography (EEG) signals. Our method capitalizes on cross-validation in conjunction with a robust evaluation metric to estimate the optimal peak-to-peak threshold – a quantity commonly used for identifying bad trials in M/EEG. This approach is then extended to a more sophisticated algorithm which estimates this threshold for each sensor yielding trial-wise bad sensors. Depending on the number of bad sensors, the trial is then repaired by interpolation or by excluding it from subsequent analysis. All steps of the algorithm are fully automated thus lending itself to the name Autoreject. In order to assess the practical significance of the algorithm, we conducted extensive validation and comparisons with state-of-the-art methods on four public datasets containing MEG and EEG recordings from more than 200 subjects. The comparisons include purely qualitative efforts as well as quantitatively benchmarking against human supervised and semi-automated preprocessing pipelines. The algorithm allowed us to automate the preprocessing of MEG data from the Human Connectome Project (HCP) going up to the computation of the evoked responses. The automated nature of our method minimizes the burden of human inspection, hence supporting scalability and reliability demanded by data analysis in modern neuroscience. [Display omitted] •A strategy for artifact rejection in M/EEG using peak-to-peak thresholds is proposed•The thresholds are estimated using cross-validation with a robust error metric•The method detects and repairs outlier data segments for each sensor•Comparison with competing methods on 200 subjects with ground truth responses
Removal of Artifacts from EEG Signals: A Review
Electroencephalogram (EEG) plays an important role in identifying brain activity and behavior. However, the recorded electrical activity always be contaminated with artifacts and then affect the analysis of EEG signal. Hence, it is essential to develop methods to effectively detect and extract the clean EEG data during encephalogram recordings. Several methods have been proposed to remove artifacts, but the research on artifact removal continues to be an open problem. This paper tends to review the current artifact removal of various contaminations. We first discuss the characteristics of EEG data and the types of different artifacts. Then, a general overview of the state-of-the-art methods and their detail analysis are presented. Lastly, a comparative analysis is provided for choosing a suitable methods according to particular application.
TOPOLOGICAL DATA ANALYSIS OF SINGLE-TRIAL ELECTROENCEPHALOGRAPHIC SIGNALS
Epilepsy is a neurological disorder marked by sudden recurrent episodes of sensory disturbance, loss of consciousness, or convulsions, associated with abnormal electrical activity in the brain. Statistical analysis of neurophysiological recordings, such as electroencephalography (EEG), facilitates the understanding of epileptic seizures. Standard statistical methods typically analyze amplitude and frequency information in EEG signals. In the current study, we propose a topological data analysis (TDA) framework to analyze single-trial EEG signals. The framework denoises signals with a weighted Fourier series (WFS), and tests for differences between the topological features—persistence landscapes (PLs) of denoised signals through resampling in the frequency domain. Simulation studies show that the test is robust for topologically similar signals while bearing sensitivity to topological tearing in signals. In an application to single-trial epileptic EEG signals, EEG signals in the diagnosed seizure origin and its symmetric site are found to have similar PLs before and during a seizure attack, in contrast to signals at other sites showing significant statistical difference in the PLs of the two phases.
Brain functional and effective connectivity based on electroencephalography recordings: A review
Functional connectivity and effective connectivity of the human brain, representing statistical dependence and directed information flow between cortical regions, significantly contribute to the study of the intrinsic brain network and its functional mechanism. Many recent studies on electroencephalography (EEG) have been focusing on modeling and estimating brain connectivity due to increasing evidence that it can help better understand various brain neurological conditions. However, there is a lack of a comprehensive updated review on studies of EEG‐based brain connectivity, particularly on visualization options and associated machine learning applications, aiming to translate those techniques into useful clinical tools. This article reviews EEG‐based functional and effective connectivity studies undertaken over the last few years, in terms of estimation, visualization, and applications associated with machine learning classifiers. Methods are explored and discussed from various dimensions, such as either linear or nonlinear, parametric or nonparametric, time‐based, and frequency‐based or time‐frequency‐based. Then it is followed by a novel review of brain connectivity visualization methods, grouped by Heat Map, data statistics, and Head Map, aiming to explore the variation of connectivity across different brain regions. Finally, the current challenges of related research and a roadmap for future related research are presented. This article reviews EEG‐based functional and effective connectivity studies undertaken over the last few years, in terms of estimation, visualization, and applications associated with machine learning classifiers. Methods are explored and discussed from various dimensions, such as either linear or nonlinear, parametric, or nonparametric, time‐based, frequency‐based or time‐frequency‐based. Then it is followed by a novel review of brain connectivity visualization methods, grouped by Heat Map, data statistics and Head Map, aiming to explore the variation of connectivity across different brain regions. Finally, the current challenges of related research and a roadmap for future related research are presented.
Smart Devices and Wearable Technologies to Detect and Monitor Mental Health Conditions and Stress: A Systematic Review
Recently, there has been an increase in the production of devices to monitor mental health and stress as means for expediting detection, and subsequent management of these conditions. The objective of this review is to identify and critically appraise the most recent smart devices and wearable technologies used to identify depression, anxiety, and stress, and the physiological process(es) linked to their detection. The MEDLINE, CINAHL, Cochrane Central, and PsycINFO databases were used to identify studies which utilised smart devices and wearable technologies to detect or monitor anxiety, depression, or stress. The included articles that assessed stress and anxiety unanimously used heart rate variability (HRV) parameters for detection of anxiety and stress, with the latter better detected by HRV and electroencephalogram (EGG) together. Electrodermal activity was used in recent studies, with high accuracy for stress detection; however, with questionable reliability. Depression was found to be largely detected using specific EEG signatures; however, devices detecting depression using EEG are not currently available on the market. This systematic review highlights that average heart rate used by many commercially available smart devices is not as accurate in the detection of stress and anxiety compared with heart rate variability, electrodermal activity, and possibly respiratory rate.
Current Status, Challenges, and Possible Solutions of EEG-Based Brain-Computer Interface: A Comprehensive Review
Brain-Computer Interface (BCI), in essence, aims at controlling different assistive devices through the utilization of brain waves. It is worth noting that the application of BCI is not limited to medical applications, and hence, the research in this field has gained due attention. Moreover, the significant number of related publications over the past two decades further indicates the consistent improvements and breakthroughs that have been made in this particular field. Nonetheless, it is also worth mentioning that with these improvements, new challenges are constantly discovered. This article provides a comprehensive review of the state-of-the-art of a complete BCI system. First, a brief overview of electroencephalogram (EEG)-based BCI systems is given. Secondly, a considerable number of popular BCI applications are reviewed in terms of electrophysiological control signals, feature extraction, classification algorithms, and performance evaluation metrics. Finally, the challenges to the recent BCI systems are discussed, and possible solutions to mitigate the issues are recommended.Brain-Computer Interface (BCI), in essence, aims at controlling different assistive devices through the utilization of brain waves. It is worth noting that the application of BCI is not limited to medical applications, and hence, the research in this field has gained due attention. Moreover, the significant number of related publications over the past two decades further indicates the consistent improvements and breakthroughs that have been made in this particular field. Nonetheless, it is also worth mentioning that with these improvements, new challenges are constantly discovered. This article provides a comprehensive review of the state-of-the-art of a complete BCI system. First, a brief overview of electroencephalogram (EEG)-based BCI systems is given. Secondly, a considerable number of popular BCI applications are reviewed in terms of electrophysiological control signals, feature extraction, classification algorithms, and performance evaluation metrics. Finally, the challenges to the recent BCI systems are discussed, and possible solutions to mitigate the issues are recommended.
Recent Progress on Microelectrodes in Neural Interfaces
Brain‒machine interface (BMI) is a promising technology that looks set to contribute to the development of artificial limbs and new input devices by integrating various recent technological advances, including neural electrodes, wireless communication, signal analysis, and robot control. Neural electrodes are a key technological component of BMI, as they can record the rapid and numerous signals emitted by neurons. To receive stable, consistent, and accurate signals, electrodes are designed in accordance with various templates using diverse materials. With the development of microelectromechanical systems (MEMS) technology, electrodes have become more integrated, and their performance has gradually evolved through surface modification and advances in biotechnology. In this paper, we review the development of the extracellular/intracellular type of in vitro microelectrode array (MEA) to investigate neural interface technology and the penetrating/surface (non-penetrating) type of in vivo electrodes. We briefly examine the history and study the recently developed shapes and various uses of the electrode. Also, electrode materials and surface modification techniques are reviewed to measure high-quality neural signals that can be used in BMI.
Lack of delta waves and sleep disturbances during non-rapid eye movement sleep in mice lacking α1G-subunit of T-type calcium channels
T-type calcium channels have been implicated as a pacemaker for brain rhythms during sleep but their contribution to behavioral states of sleep has been relatively uncertain. Here, we found that mice lacking α1 G T-type Ca 2+ channels showed a loss of the thalamic delta (1–4 Hz) waves and a reduction of sleep spindles (7–14 Hz), whereas slow (<1 Hz) rhythms were relatively intact, when compared with the wild-type during urethane anesthesia and non-rapid eye movement (NREM) sleep. Analysis of sleep disturbances, as defined by the occurrence of brief awakening (BA) episodes during NREM sleep, revealed that mutant mice exhibited a higher incidence of BAs of >16 sec compared with the wild-type, whereas no difference was seen in BAs of <16 sec between the two genotypes. These results are consistent with the previous idea of the distinct nature of delta oscillations and sleep spindles from cortically generated slow waves. These results also suggest that the α1 G -subunit of T-type calcium channels plays a critical role in the genesis of thalamocortical oscillations and contributes to the modulation of sleep states and the transition between NREM sleep and wake states. electroencephalogram oscillations thalamus
High-speed spelling with a noninvasive brain–computer interface
The past 20 years have witnessed unprecedented progress in brain–computer interfaces (BCIs). However, low communication rates remain key obstacles to BCI-based communication in humans. This study presents an electroencephalogram-based BCI speller that can achieve information transfer rates (ITRs) up to 5.32 bits per second, the highest ITRs reported in BCI spellers using either noninvasive or invasive methods. Based on extremely high consistency of frequency and phase observed between visual flickering signals and the elicited single-trial steady-state visual evoked potentials, this study developed a synchronous modulation and demodulation paradigm to implement the speller. Specifically, this study proposed a new joint frequency-phase modulation method to tag 40 characters with 0.5-s-long flickering signals and developed a user-specific target identification algorithm using individual calibration data. The speller achieved high ITRs in online spelling tasks. This study demonstrates that BCIs can provide a truly naturalistic high-speed communication channel using noninvasively recorded brain activities.