Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
1,953 result(s) for "Electromyography - instrumentation"
Sort by:
Validation of a Novel Wearable Electromyography Patch for Monitoring Submental Muscle Activity During Swallowing: A Randomized Crossover Trial
Purpose: Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this first-generation sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method: A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5- and 10-ml water. Comparisons were made on (a) signal-related factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors. Results: Forty healthy adults participated (24 women, M[subscript age] = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes (p < 0.0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes (p < 0.0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < 0.025; 10 ml: p < 0.0012), and sEMG burst duration was also equivalent (5 ml: p < 0.0001; 10 ml: p < 0.0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch (p = 0.0476, d = 0.226). Conclusions: Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia.
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
Purpose We evaluated the electromyography (EMG)-based neuromuscular monitoring detectability of our novel stimulating electrode attachment method compared to the original Nihon–Kohden (Tokyo, Japan) attachment method. Methods This single-center randomized, double-blind, controlled pilot study enrolled 32 patients aged ≥ 18 years, undergoing scheduled laparoscopic surgery. The EMG electrode NM-345Y™ was attached to one forearm using the Nihon–Kohden method (Pattern N–K) and the other forearm using our novel method (Pattern Cross). The allocation to each attachment method was determined post-randomization. In Pattern Cross, the NM-345Y™ was attached such that the line connecting the anode and cathode crosses the ulnar nerve. Patients received 0.9 mg/kg rocuronium after calibration with the forearm in 90-degree supination. Following tracheal intubation, the forearm was positioned in 0-degree pronation. Intraoperatively, 0.2 mg/kg rocuronium was administered if the train-of-four (TOF) count one persisted for 1 min on either side. Post-surgery, the forearm position was returned to 90-degree supination, and rocuronium was antagonized with sugammadex. TOF and post-tetanic count (PTC) were simultaneously measured bilaterally every 15 s and 5 min, respectively, from post-calibration to tracheal extubation. Results The time to first PTC appearance was significantly shorter by 33 min in the Pattern Cross group than in the Pattern N–K group (95% Confidence interval: 1–66, p  = 0.043). Following sugammadex administration, TOF ratios ≥ 0.9 were achieved in 72% of patients in the Pattern N–K group and 97% of those in the Pattern Cross group ( p  = 0.025). Conclusions Crossing the line connecting the anode and cathode with the ulnar nerve stabilizes EMG-based neuromuscular monitoring detectability.
The effects of a single session of chiropractic care on strength, cortical drive, and spinal excitability in stroke patients
The objective of this study was to investigate whether a single session of chiropractic care could increase strength in weak plantar flexor muscles in chronic stroke patients. Maximum voluntary contractions (strength) of the plantar flexors, soleus evoked V-waves (cortical drive), and H-reflexes were recorded in 12 chronic stroke patients, with plantar flexor muscle weakness, using a randomized controlled crossover design. Outcomes were assessed pre and post a chiropractic care intervention and a passive movement control. Repeated measures ANOVA was used to asses within and between group differences. Significance was set at p < 0.05. Following the chiropractic care intervention there was a significant increase in strength (F (1,11) = 14.49, p = 0.002; avg 64.2 ± 77.7%) and V-wave/Mmax ratio (F(1,11) = 9.67, p = 0.009; avg 54.0 ± 65.2%) compared to the control intervention. There was a significant strength decrease of 26.4 ± 15.5% (p = 0.001) after the control intervention. There were no other significant differences. Plantar flexor muscle strength increased in chronic stroke patients after a single session of chiropractic care. An increase in V-wave amplitude combined with no significant changes in H-reflex parameters suggests this increased strength is likely modulated at a supraspinal level. Further research is required to investigate the longer term and potential functional effects of chiropractic care in stroke recovery.
EMG-based vibro-tactile biofeedback training: effective learning accelerator for children and adolescents with dystonia? A pilot crossover trial
Background This study is aimed at better understanding the role of a wearable and silent ElectroMyoGraphy-based biofeedback on motor learning in children and adolescents with primary and secondary dystonia. Methods A crossover study with a wash-out period of at least 1 week was designed; the device provides the patient with a vibration proportional to the activation of an impaired target muscle. The protocol consisted of two 5-day blocks during which subjects were trained and tested on a figure-8 writing task: their performances (at different levels of difficulty) were evaluated in terms of both kinematics and muscular activations on day 1 and day 5, while the other 3 days were purely used as training sessions. The training was performed with and without using the biofeedback device: the week of use was randomized. Data were collected on 14 subjects with primary and secondary (acquired) dystonia (age: 6–19 years). Results Results comparing kinematic-based and EMG-based outcome measures pre- and post-training showed learning due to practice for both subjects with primary and secondary dystonia. On top of said learning, an improvement in terms of inter-joint coordination and muscular pattern functionality was recorded only for secondary dystonia subjects, when trained with the aid of the EMG-based biofeedback device. Conclusions Our results support the hypothesis that children and adolescents with primary dystonia in which there is intact sensory processing do not benefit from feedback augmentation, whereas children with secondary dystonia, in which sensory deficits are often present, exhibit a higher learning capacity when augmented movement-related sensory information is provided. This study represents a fundamental investigation to address the scarcity of noninvasive therapeutic interventions for young subjects with dystonia.
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
When mounted on the skin, modern sensors, circuits, radios, and power supply systems have the potential to provide clinical-quality health monitoring capabilities for continuous use, beyond the confines of traditional hospital or laboratory facilities. The most well-developed component technologies are, however, broadly available only in hard, planar formats. As a result, existing options in system design are unable to effectively accommodate integration with the soft, textured, curvilinear, and time-dynamic surfaces of the skin. Here, we describe experimental and theoretical approaches for using ideas in soft microfluidics, structured adhesive surfaces, and controlled mechanical buckling to achieve ultralow modulus, highly stretchable systems that incorporate assemblies of high-modulus, rigid, state-of-the-art functional elements. The outcome is a thin, conformable device technology that can softly laminate onto the surface of the skin to enable advanced, multifunctional operation for physiological monitoring in a wireless mode.
A universal interface for plug-and-play assembly of stretchable devices
Stretchable hybrid devices have enabled high-fidelity implantable 1 – 3 and on-skin 4 – 6 monitoring of physiological signals. These devices typically contain soft modules that match the mechanical requirements in humans 7 , 8 and soft robots 9 , 10 , rigid modules containing Si-based microelectronics 11 , 12 and protective encapsulation modules 13 , 14 . To make such a system mechanically compliant, the interconnects between the modules need to tolerate stress concentration that may limit their stretching and ultimately cause debonding failure 15 – 17 . Here, we report a universal interface that can reliably connect soft, rigid and encapsulation modules together to form robust and highly stretchable devices in a plug-and-play manner. The interface, consisting of interpenetrating polymer and metal nanostructures, connects modules by simply pressing without using pastes. Its formation is depicted by a biphasic network growth model. Soft–soft modules joined by this interface achieved 600% and 180% mechanical and electrical stretchability, respectively. Soft and rigid modules can also be electrically connected using the above interface. Encapsulation on soft modules with this interface is strongly adhesive with an interfacial toughness of 0.24 N mm −1 . As a proof of concept, we use this interface to assemble stretchable devices for in vivo neuromodulation and on-skin electromyography, with high signal quality and mechanical resistance. We expect such a plug-and-play interface to simplify and accelerate the development of on-skin and implantable stretchable devices. A universal interface connects soft, rigid and encapsulation modules together to form robust, stretchable devices in a plug-and-play manner by pressing without using pastes, which will simplify and accelerate development of on-skin and implantable devices.
Comparison of six electromyography acquisition setups on hand movement classification tasks
Hand prostheses controlled by surface electromyography are promising due to the non-invasive approach and the control capabilities offered by machine learning. Nevertheless, dexterous prostheses are still scarcely spread due to control difficulties, low robustness and often prohibitive costs. Several sEMG acquisition setups are now available, ranging in terms of costs between a few hundred and several thousand dollars. The objective of this paper is the relative comparison of six acquisition setups on an identical hand movement classification task, in order to help the researchers to choose the proper acquisition setup for their requirements. The acquisition setups are based on four different sEMG electrodes (including Otto Bock, Delsys Trigno, Cometa Wave + Dormo ECG and two Thalmic Myo armbands) and they were used to record more than 50 hand movements from intact subjects with a standardized acquisition protocol. The relative performance of the six sEMG acquisition setups is compared on 41 identical hand movements with a standardized feature extraction and data analysis pipeline aimed at performing hand movement classification. Comparable classification results are obtained with three acquisition setups including the Delsys Trigno, the Cometa Wave and the affordable setup composed of two Myo armbands. The results suggest that practical sEMG tests can be performed even when costs are relevant (e.g. in small laboratories, developing countries or use by children). All the presented datasets can be used for offline tests and their quality can easily be compared as the data sets are publicly available.
Motor unit potentials of the erector spinae muscle by concentric needle electromyography
Introduction The needle electromyography (EMG) serves to supply additional information in patients with suspected neuromuscular disorders. We aimed to provide motor unit potential (MUP) data by concentric needle EMG in the erector spinae (ES) in comparison with biceps brachii (BB) and lateral vastus (LV). Methods Electromyography MUP data (n) were obtained in ES (517), BB (539), and LV (627) in 32 healthy volunteers (16f). Results Motor unit potential data: amplitude (μV) 393 ± 174 (ES), 375 ± 162 (BB), and 577 ± 304 (LV); duration (ms) 10.4 ± 2.4 (ES), 10.1 ± 2.1 (BB), and 11.1 ± 2.3 (LV), area (μV × ms) 585 ± 327 (ES), 538 ± 267 (BB), and 881 ± 492 (LV); phase number 3.23 ± 0.94 (ES), 2.98 ± 0.76 (BB), and 3.19 ± 0.81 (LV); size index 0.60 ± 0.56 (ES), 0.51 ± 0.53 (BB), and 0.96 ± 0.55 (LV). LV displayed higher values (p at least <.001) for MUP amplitude, duration, area, and size index as compared to both, BB and ES. Conclusion Concentric needle EMG investigations in healthy adult human subjects revealed similar MUP parameters in the ES and BB muscles, while in the LV muscle MUP amplitude, duration, area, and size index were significantly larger. Different neuromuscular disorders display a predominant involvement of proximally located muscles such as truncal muscles. The present results given here may facilitate the diagnosis of neuromuscular disorders. The needle electromyography (EMG) serves to supply additional information in patients with suspected neuromuscular disorders. We aimed to provide motor unit potential data by concentric needle EMG in the erector spinae in comparison with biceps brachii and lateral vastus. The present results given here may facilitate the diagnosis of neuromuscular disorders.
An Embedded Electromyogram Signal Acquisition Device
In this study, we design an embedded surface EMG acquisition device to conveniently collect human surface EMG signals, pursue more intelligent human–computer interactions in exoskeleton robots, and enable exoskeleton robots to synchronize with or even respond to user actions in advance. The device has the characteristics of low cost, miniaturization, and strong compatibility, and it can acquire eight-channel surface EMG signals in real time while retaining the possibility of expanding the channel. This paper introduces the design and function of the embedded EMG acquisition device in detail, which includes the use of wired transmission to adapt to complex electromagnetic environments, light signals to indicate signal strength, and an embedded processing chip to reduce signal noise and perform filtering. The test results show that the device can effectively collect the original EMG signal, which provides a scheme for improving the level of human–computer interactions and enhancing the robustness and intelligence of exoskeleton equipment. The development of this device provides a new possibility for the intellectualization of exoskeleton systems and reductions in their cost.
Epidermal Electronics
We report classes of electronic systems that achieve thicknesses, effective elastic moduli, bending stiffnesses, and areal mass densities matched to the epidermis. Unlike traditional wafer-based technologies, laminating such devices onto the skin leads to conformal contact and adequate adhesion based on van der Waals interactions alone, in a manner that is mechanically invisible to the user. We describe systems incorporating electrophysiological, temperature, and strain sensors, as well as transistors, light-emitting diodes, photodetectors, radio frequency inductors, capacitors, oscillators, and rectifying diodes. Solar cells and wireless coils provide options for power supply. We used this type of technology to measure electrical activity produced by the heart, brain, and skeletal muscles and show that the resulting data contain sufficient information for an unusual type of computer game controller.