MbrlCatalogueTitleDetail

Do you wish to reserve the book?
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study
Journal Article

A novel stimulating electrode attachment method designed to maintain electromyography-based neuromuscular monitoring detectability during laparoscopic surgery: a single-center randomized, double-blind, controlled pilot study

2024
Request Book From Autostore and Choose the Collection Method
Overview
Purpose We evaluated the electromyography (EMG)-based neuromuscular monitoring detectability of our novel stimulating electrode attachment method compared to the original Nihon–Kohden (Tokyo, Japan) attachment method. Methods This single-center randomized, double-blind, controlled pilot study enrolled 32 patients aged ≥ 18 years, undergoing scheduled laparoscopic surgery. The EMG electrode NM-345Y™ was attached to one forearm using the Nihon–Kohden method (Pattern N–K) and the other forearm using our novel method (Pattern Cross). The allocation to each attachment method was determined post-randomization. In Pattern Cross, the NM-345Y™ was attached such that the line connecting the anode and cathode crosses the ulnar nerve. Patients received 0.9 mg/kg rocuronium after calibration with the forearm in 90-degree supination. Following tracheal intubation, the forearm was positioned in 0-degree pronation. Intraoperatively, 0.2 mg/kg rocuronium was administered if the train-of-four (TOF) count one persisted for 1 min on either side. Post-surgery, the forearm position was returned to 90-degree supination, and rocuronium was antagonized with sugammadex. TOF and post-tetanic count (PTC) were simultaneously measured bilaterally every 15 s and 5 min, respectively, from post-calibration to tracheal extubation. Results The time to first PTC appearance was significantly shorter by 33 min in the Pattern Cross group than in the Pattern N–K group (95% Confidence interval: 1–66, p  = 0.043). Following sugammadex administration, TOF ratios ≥ 0.9 were achieved in 72% of patients in the Pattern N–K group and 97% of those in the Pattern Cross group ( p  = 0.025). Conclusions Crossing the line connecting the anode and cathode with the ulnar nerve stabilizes EMG-based neuromuscular monitoring detectability.