Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
919
result(s) for
"Fluidic circuits"
Sort by:
CMOS‐Inspired Complementary Fluidic Circuits for Soft Robots
2021
The latest efforts in digital fluidic circuits’ research aim at being electronics‐free, light‐weight, and compliant controllers for soft robots; however, challenges arise to adjust the fluidic circuit's digital logic operations. Currently there is no other way to modulate the amplitude or frequency but to structurally redesign the entire fluidic circuitry. This is mainly because there is currently no method to create an analog circuit‐like behavior in the digital fluidic circuits using conventional digitized fluidic gates. In this work, a new approach is presented to designing a circuit with digitized fluidic gates that is comparable to an analog circuit capable of actively tuning the circuit's fluidic characteristics, such as pressure gain, amplitude of output, and time response. For the first time, a pressure‐controlled oscillator is modeled, designed, and prototyped that not only controls the fluidic oscillation, but also modulates its frequency using only a single, quasi‐static pressure input. It can also demonstrate the circuit's performance for the control of a soft robotic system by actively modulating the motion of a soft earthworm robot up to twice of crawling speeds. This work has distinct contributions to designing and building intelligent pneumatic controllers toward truly comprehensive soft robotic systems. This paper reports a complementary metal‐oxide‐semiconductor‐inspired fluidic circuit design and components to actively control analog properties of digital fluidic logics. The proposed method enables to develop the first controllable fluidic self‐oscillation circuit that cannot only switch between “crawling” and “stop” status of a soft robot, but also can change the robot's crawling speed only using a single pressure input.
Journal Article
Advanced iontronic spiking modes with multiscale diffusive dynamics in a fluidic circuit
2024
Fluidic iontronics is emerging as a distinctive platform for implementing neuromorphic circuits, characterised by its reliance on the same aqueous medium and ionic signal carriers as the brain. Drawing upon recent theoretical advancements in both iontronic spiking circuits and in dynamic conductance of conical ion channels, which form fluidic memristors, we expand the repertoire of proposed neuronal spiking dynamics in iontronic circuits. Through a modelled circuit containing channels that carry a bipolar surface charge, we extract phasic bursting, mixed-mode spiking, tonic bursting, and threshold variability, all with spike voltages and frequencies within the typical range for mammalian neurons. These features are possible due to the strong dependence of the typical conductance memory retention time on the channel length, enabling timescales varying from individual spikes to bursts of multiple spikes within a single circuit. These advanced forms of neuronal-like spiking support the exploration of aqueous iontronics as an interesting platform for neuromorphic circuits.
Journal Article
Quantification of Blood Viscoelasticity under Microcapillary Blood Flow
2023
Blood elasticity is quantified using a single compliance model by analyzing pulsatile blood flow. However, one compliance coefficient is influenced substantially by the microfluidic system (i.e., soft microfluidic channels and flexible tubing). The novelty of the present method comes from the assessment of two distinct compliance coefficients, one for the sample and one for the microfluidic system. With two compliance coefficients, the viscoelasticity measurement can be disentangled from the influence of the measurement device. In this study, a coflowing microfluidic channel was used to estimate blood viscoelasticity. Two compliance coefficients were suggested to denote the effects of the polydimethylsiloxane (PDMS) channel and flexible tubing (C1), as well as those of the RBC (red blood cell) elasticity (C2), in a microfluidic system. On the basis of the fluidic circuit modeling technique, a governing equation for the interface in the coflowing was derived, and its analytical solution was obtained by solving the second-order differential equation. Using the analytic solution, two compliance coefficients were obtained via a nonlinear curve fitting technique. According to the experimental results, C2/C1 is estimated to be approximately 10.9–20.4 with respect to channel depth (h = 4, 10, and 20 µm). The PDMS channel depth contributed simultaneously to the increase in the two compliance coefficients, whereas the outlet tubing caused a decrease in C1. The two compliance coefficients and blood viscosity varied substantially with respect to homogeneous hardened RBCs or heterogeneous hardened RBCs. In conclusion, the proposed method can be used to effectively detect changes in blood or microfluidic systems. In future studies, the present method can contribute to the detection of subpopulations of RBCs in the patient’s blood.
Journal Article
Assessment of Blood Biophysical Properties Using Pressure Sensing with Micropump and Microfluidic Comparator
2022
To identify the biophysical properties of blood samples consistently, macroscopic pumps have been used to maintain constant flow rates in a microfluidic comparator. In this study, the bulk-sized and expensive pump is replaced with a cheap and portable micropump. A specific reference fluid (i.e., glycerin solution [40%]) with a small volume of red blood cell (RBC) (i.e., 1% volume fraction) as fluid tracers is supplied into the microfluidic comparator. An averaged velocity () obtained with micro-particle image velocimetry is converted into the flow rate of reference fluid (Qr) (i.e., Qr = CQ × Ac × , Ac: cross-sectional area, CQ = 1.156). Two control variables of the micropump (i.e., frequency: 400 Hz and volt: 150 au) are selected to guarantee a consistent flow rate (i.e., COV < 1%). Simultaneously, the blood sample is supplied into the microfluidic channel under specific flow patterns (i.e., constant, sinusoidal, and periodic on-off fashion). By monitoring the interface in the comparator as well as Qr, three biophysical properties (i.e., viscosity, junction pressure, and pressure-induced work) are obtained using analytical expressions derived with a discrete fluidic circuit model. According to the quantitative comparison results between the present method (i.e., micropump) and the previous method (i.e., syringe pump), the micropump provides consistent results when compared with the syringe pump. Thereafter, representative biophysical properties, including the RBC aggregation, are consistently obtained for specific blood samples prepared with dextran solutions ranging from 0 to 40 mg/mL. In conclusion, the present method could be considered as an effective method for quantifying the physical properties of blood samples, where the reference fluid is supplied with a cheap and portable micropump.
Journal Article
Microfluidic-Based Technique for Measuring RBC Aggregation and Blood Viscosity in a Continuous and Simultaneous Fashion
2018
Hemorheological properties such as viscosity, deformability, and aggregation have been employed to monitor or screen patients with cardiovascular diseases. To effectively evaluate blood circulating within an in vitro closed circuit, it is important to quantify its hemorheological properties consistently and accurately. A simple method for measuring red blood cell (RBC) aggregation and blood viscosity is proposed for analyzing blood flow in a microfluidic device, especially in a continuous and simultaneous fashion. To measure RBC aggregation, blood flows through three channels: the left wide channel, the narrow channel and the right wide channel sequentially. After quantifying the image intensity of RBCs aggregated in the left channel () and the RBCs disaggregated in the right channel (), the RBC aggregation index (AIPM) is obtained by dividing by . Simultaneously, based on a modified parallel flow method, blood viscosity is obtained by detecting the interface between two fluids in the right wide channel. RBC aggregation and blood viscosity were first evaluated under constant and pulsatile blood flows. AIPM varies significantly with respect to blood flow rate (for both its amplitude and period) and the concentration of the dextran solution used. According to our quantitative comparison between the proposed aggregation index (AIPM) and the conventional aggregation index (AICM), it is found that AIPM provides consistent results. Finally, the suggested method is employed to obtain the RBC aggregation and blood viscosity of blood circulating within an in vitro fluidic circuit. The experimental results lead to the conclusion that the proposed method can be successfully used to measure RBC aggregation and blood viscosity, especially in a continuous and simultaneous fashion.
Journal Article
Routing of Fluidic Circuits Using Skeletons of Polygonal Figures and Compound Splines
2021
Routing of channels between elementary fluidic elements is an important stage in the design of new fluidic devices. This paper considers usage skeletons of polygonal figures and compound splines in routing of fluidic circuits.
Journal Article
Ultracompact 3D microfluidics for time-resolved structural biology
by
Bajt, Saša
,
Chapman, Henry N.
,
Yefanov, Oleksandr
in
101/62
,
3-D printers
,
3-D reconstruction
2020
To advance microfluidic integration, we present the use of two-photon additive manufacturing to fold 2D channel layouts into compact free-form 3D fluidic circuits with nanometer precision. We demonstrate this technique by tailoring microfluidic nozzles and mixers for time-resolved structural biology at X-ray free-electron lasers (XFELs). We achieve submicron jets with speeds exceeding 160 m s
−1
, which allows for the use of megahertz XFEL repetition rates. By integrating an additional orifice, we implement a low consumption flow-focusing nozzle, which is validated by solving a hemoglobin structure. Also, aberration-free in operando X-ray microtomography is introduced to study efficient equivolumetric millisecond mixing in channels with 3D features integrated into the nozzle. Such devices can be printed in minutes by locally adjusting print resolution during fabrication. This technology has the potential to permit ultracompact devices and performance improvements through 3D flow optimization in all fields of microfluidic engineering.
There is a need for more robust sample delivery methods for serial crystallography. Here the authors present the design and characterization of ultracompact 3D microfluidic devices that can be printed, which require less sample, have a lower background signal and allow 3D mixing for time resolved experiments.
Journal Article
Discrete elements for 3D microfluidics
by
Thompson, Bryant
,
Bhargava, Krisna C.
,
Malmstadt, Noah
in
Biochemistry
,
Biophysics
,
Chemical elements
2014
Microfluidic systems are rapidly becoming commonplace tools for high-precision materials synthesis, biochemical sample preparation, and biophysical analysis. Typically, microfluidic systems are constructed in monolithic form by means of microfabrication and, increasingly, by additive techniques. These methods restrict the design and assembly of truly complex systems by placing unnecessary emphasis on complete functional integration of operational elements in a planar environment. Here, we present a solution based on discrete elements that liberates designers to build large-scale microfluidic systems in three dimensions that are modular, diverse, and predictable by simple network analysis techniques. We develop a sample library of standardized components and connectors manufactured using stereolithography. We predict and validate the flow characteristics of these individual components to design and construct a tunable concentration gradient generator with a scalable number of parallel outputs. We show that these systems are rapidly reconfigurable by constructing three variations of a device for generating monodisperse microdroplets in two distinct size regimes and in a high-throughput mode by simple replacement of emulsifier subcircuits. Finally, we demonstrate the capability for active process monitoring by constructing an optical sensing element for detecting water droplets in a fluorocarbon stream and quantifying their size and frequency. By moving away from large-scale integration toward standardized discrete elements, we demonstrate the potential to reduce the practice of designing and assembling complex 3D microfluidic circuits to a methodology comparable to that found in the electronics industry.
Significance Microfluidic systems promise to improve the analysis and synthesis of materials, biological or otherwise, by lowering the required volume of fluid samples, offering a tightly controlled fluid-handling environment, and simultaneously integrating various chemical processes. To build these systems, designers depend on microfabrication techniques that restrict them to arranging their designs in two dimensions and completely fabricating their design in a single step. This study introduces modular, reconfigurable components containing fluidic and sensor elements adaptable to many different microfluidic circuits. These elements can be assembled to allow for 3D routing of channels. This assembly approach allows for the application of network analysis techniques like those used in classical electronic circuit design, facilitating the straightforward design of predictable flow systems.
Journal Article
Manufacturing the multiscale vascular hierarchy: progress toward solving the grand challenge of tissue engineering
2023
Vasculature within the human body is arranged in a hierarchical manner, beginning with large macrovessels that taper into smaller mesovessels, and finally into the smallest microvessels.Replicating this hierarchical vasculature within engineered tissue constructs is a critical hurdle for the clinical translation of engineered tissues and organs.A major limitation to the development of hierarchical vasculature are the distinct and diverse fabrication strategies required for creating vasculature at each scale.New advances in fabrication strategies, particularly 3D bioprinting, are enabling the engineering of a multiscale vascular hierarchy within a single 3D tissue construct.Multidisciplinary collaboration and cooperation between experts in academia, industry, and government will be essential to address this grand challenge and further propel hierarchical vasculature toward clinical and commercial success.
In human vascular anatomy, blood flows from the heart to organs and tissues through a hierarchical vascular tree, comprising large arteries that branch into arterioles and further into capillaries, where gas and nutrient exchange occur. Engineering a complete, integrated vascular hierarchy with vessels large enough to suture, strong enough to withstand hemodynamic forces, and a branching structure to permit immediate perfusion of a fluidic circuit across scales would be transformative for regenerative medicine (RM), enabling the translation of engineered tissues of clinically relevant size, and perhaps whole organs. How close are we to solving this biological plumbing problem? In this review, we highlight advances in engineered vasculature at individual scales and focus on recent strategies to integrate across scales.
Journal Article
A digital twin design methodology for control, simulation, and monitoring of fluidic circuits
2024
This article proposes a methodology for the design of digital twins applicable to various systems (pneumatic, hydraulic, electrical/electronic circuits). The methodology allows representing the operation of these systems through an active digital twin, enabling the simulation, control, and monitoring through a more suitable and powerful computer-aided design. Furthermore, this methodology enables the detection of a system’s actions on its own inputs (for instance, in pneumatics: backflow of gases trapped in parts of a fluidic system into its own inputs). During the simulation or monitoring phase, the approach also facilitates real-time diagnosis of the physical system. The outputs of the controlled physical system or its digital twin do not depend only on the current inputs but also on the history of the inputs and the history of internal states and variables. In other words, the underlying sequential behavior logic has a memory while an combinational logic approach alone has not. These modeling capabilities can contribute to the digital transformation of the design, control, simulation, and manufacturing systems.
Journal Article