Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
1,260
result(s) for
"Genomics - instrumentation"
Sort by:
The Oxford Nanopore MinION: delivery of nanopore sequencing to the genomics community
2016
Nanopore DNA strand sequencing has emerged as a competitive, portable technology. Reads exceeding 150 kilobases have been achieved, as have in-field detection and analysis of clinical pathogens. We summarize key technical features of the Oxford Nanopore MinION, the dominant platform currently available. We then discuss pioneering applications executed by the genomics community.
Journal Article
Computational tools to unmask transposable elements
2018
A substantial proportion of the genome of many species is derived from transposable elements (TEs). Moreover, through various self-copying mechanisms, TEs continue to proliferate in the genomes of most species. TEs have contributed numerous regulatory, transcript and protein innovations and have also been linked to disease. However, notwithstanding their demonstrated impact, many genomic studies still exclude them because their repetitive nature results in various analytical complexities. Fortunately, a growing array of methods and software tools are being developed to cater for them. This Review presents a summary of computational resources for TEs and highlights some of the challenges and remaining gaps to perform comprehensive genomic analyses that do not simply ‘mask’ repeats.
Journal Article
Sequencing of human genomes with nanopore technology
2019
Whole-genome sequencing (WGS) is becoming widely used in clinical medicine in diagnostic contexts and to inform treatment choice. Here we evaluate the potential of the Oxford Nanopore Technologies (ONT) MinION long-read sequencer for routine WGS by sequencing the reference sample NA12878 and the genome of an individual with ataxia-pancytopenia syndrome and severe immune dysregulation. We develop and apply a novel reference panel-free analytical method to infer and then exploit phase information which improves single-nucleotide variant (SNV) calling performance from otherwise modest levels. In the clinical sample, we identify and directly phase two non-synonymous de novo variants in
SAMD9L
, (OMIM #159550) inferring that they lie on the same paternal haplotype. Whilst consensus SNV-calling error rates from ONT data remain substantially higher than those from short-read methods, we demonstrate the substantial benefits of analytical innovation. Ongoing improvements to base-calling and SNV-calling methodology must continue for nanopore sequencing to establish itself as a primary method for clinical WGS.
Nanopore sequencing technology generates longer reads than current technologies, but with more errors. Here, the authors develop new analytical tools to improve accuracy and evaluate the potential of nanopore sequencing for clinical human genomics.
Journal Article
An integrated semiconductor device enabling non-optical genome sequencing
by
Stoner, Isaac B.
,
Myers, Jason W.
,
Cawley, Simon E.
in
631/1647/1888
,
631/61/514/1948
,
639/301/119/1000
2011
The seminal importance of DNA sequencing to the life sciences, biotechnology and medicine has driven the search for more scalable and lower-cost solutions. Here we describe a DNA sequencing technology in which scalable, low-cost semiconductor manufacturing techniques are used to make an integrated circuit able to directly perform non-optical DNA sequencing of genomes. Sequence data are obtained by directly sensing the ions produced by template-directed DNA polymerase synthesis using all-natural nucleotides on this massively parallel semiconductor-sensing device or ion chip. The ion chip contains ion-sensitive, field-effect transistor-based sensors in perfect register with 1.2 million wells, which provide confinement and allow parallel, simultaneous detection of independent sequencing reactions. Use of the most widely used technology for constructing integrated circuits, the complementary metal-oxide semiconductor (CMOS) process, allows for low-cost, large-scale production and scaling of the device to higher densities and larger array sizes. We show the performance of the system by sequencing three bacterial genomes, its robustness and scalability by producing ion chips with up to 10 times as many sensors and sequencing a human genome.
'Post-light' genome sequencing chips
Progress towards cheaper and more compact DNA sequencing devices is limited by a number of factors, including the need for imaging technology. A new DNA sequencing technology that does away with optical readout, instead gathering sequence data by directly sensing hydrogen ions produced by template-directed DNA synthesis, offers a route to low cost and scalable sequencing on a massively parallel semiconductor-sensing device or ion chip. The reactions are performed using all natural nucleotides, and the individual ion-sensitive chips are disposable and inexpensive. The system has been used to sequence three bacterial genomes and a human genome: that of Gordon Moore of Moore's law fame.
Journal Article
A large genome center's improvements to the Illumina sequencing system
by
Scally, Aylwyn
,
Smith, Frances
,
Quail, Michael A
in
Academies and Institutes
,
Bioinformatics
,
Biological Microscopy
2008
The Wellcome Trust Sanger Institute is one of the world's largest genome centers, and a substantial amount of our sequencing is performed with 'next-generation' massively parallel sequencing technologies: in June 2008 the quantity of purity-filtered sequence data generated by our Genome Analyzer (Illumina) platforms reached 1 terabase, and our average weekly Illumina production output is currently 64 gigabases. Here we describe a set of improvements we have made to the standard Illumina protocols to make the library preparation more reliable in a high-throughput environment, to reduce bias, tighten insert size distribution and reliably obtain high yields of data.
Journal Article
RCircos: an R package for Circos 2D track plots
2013
Background
Circos is a Perl language based software package for visualizing similarities and differences of genome structure and positional relationships between genomic intervals. Running Circos requires extra data processing procedures to prepare plot data files and configure files from datasets, which limits its capability of integrating directly with other software tools such as R. Recently published R Bioconductor package ggbio provides a function to display genomic data in circular layout based on multiple other packages, which increases its complexity of usage and decreased the flexibility in integrating with other R pipelines.
Results
We implemented an R package, RCircos, using only R packages that come with R base installation. The package supports Circos 2D data track plots such as scatter, line, histogram, heatmap, tile, connectors, links, and text labels. Each plot is implemented with a specific function and input data for all functions are data frames which can be objects read from text files or generated with other R pipelines.
Conclusion
RCircos package provides a simple and flexible way to make Circos 2D track plots with R and could be easily integrated into other R data processing and graphic manipulation pipelines for presenting large-scale multi-sample genomic research data. It can also serve as a base tool to generate complex Circos images.
Journal Article
De novo yeast genome assemblies from MinION, PacBio and MiSeq platforms
2017
Long-read sequencing technologies such as Pacific Biosciences and Oxford Nanopore MinION are capable of producing long sequencing reads with average fragment lengths of over 10,000 base-pairs and maximum lengths reaching 100,000 base- pairs. Compared with short reads, the assemblies obtained from long-read sequencing platforms have much higher contig continuity and genome completeness as long fragments are able to extend paths into problematic or repetitive regions. Many successful assembly applications of the Pacific Biosciences technology have been reported ranging from small bacterial genomes to large plant and animal genomes. Recently, genome assemblies using Oxford Nanopore MinION data have attracted much attention due to the portability and low cost of this novel sequencing instrument. In this paper, we re-sequenced a well characterized genome, the
Saccharomyces cerevisiae
S288C strain using three different platforms: MinION, PacBio and MiSeq. We present a comprehensive metric comparison of assemblies generated by various pipelines and discuss how the platform associated data characteristics affect the assembly quality. With a given read depth of 31X, the assemblies from both Pacific Biosciences and Oxford Nanopore MinION show excellent continuity and completeness for the 16 nuclear chromosomes, but not for the mitochondrial genome, whose reconstruction still represents a significant challenge.
Journal Article
ViralFlow: A Versatile Automated Workflow for SARS-CoV-2 Genome Assembly, Lineage Assignment, Mutations and Intrahost Variant Detection
by
Almeida, Suzana Porto
,
Jeronimo, Pedro Miguel Carneiro
,
Neto, Antonio Marinho da Silva
in
automation
,
Automation, Laboratory - methods
,
Bioinformatics
2022
The COVID-19 pandemic is driven by Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) that emerged in 2019 and quickly spread worldwide. Genomic surveillance has become the gold standard methodology used to monitor and study this fast-spreading virus and its constantly emerging lineages. The current deluge of SARS-CoV-2 genomic data generated worldwide has put additional pressure on the urgent need for streamlined bioinformatics workflows. Here, we describe a workflow developed by our group to process and analyze large-scale SARS-CoV-2 Illumina amplicon sequencing data. This workflow automates all steps of SARS-CoV-2 reference-based genomic analysis: data processing, genome assembly, PANGO lineage assignment, mutation analysis and the screening of intrahost variants. The pipeline is capable of processing a batch of around 100 samples in less than half an hour on a personal laptop or in less than five minutes on a server with 50 threads. The workflow presented here is available through Docker or Singularity images, allowing for implementation on laptops for small-scale analyses or on high processing capacity servers or clusters. Moreover, the low requirements for memory and CPU cores and the standardized results provided by ViralFlow highlight it as a versatile tool for SARS-CoV-2 genomic analysis.
Journal Article
High-throughput automated microfluidic sample preparation for accurate microbial genomics
2017
Low-cost shotgun DNA sequencing is transforming the microbial sciences. Sequencing instruments are so effective that sample preparation is now the key limiting factor. Here, we introduce a microfluidic sample preparation platform that integrates the key steps in cells to sequence library sample preparation for up to 96 samples and reduces DNA input requirements 100-fold while maintaining or improving data quality. The general-purpose microarchitecture we demonstrate supports workflows with arbitrary numbers of reaction and clean-up or capture steps. By reducing the sample quantity requirements, we enabled low-input (∼10,000 cells) whole-genome shotgun (WGS) sequencing of
Mycobacterium tuberculosis
and soil micro-colonies with superior results. We also leveraged the enhanced throughput to sequence ∼400 clinical
Pseudomonas aeruginosa
libraries and demonstrate excellent single-nucleotide polymorphism detection performance that explained phenotypically observed antibiotic resistance. Fully-integrated lab-on-chip sample preparation overcomes technical barriers to enable broader deployment of genomics across many basic research and translational applications.
Shotgun DNA sequencing experiments for microbial genomic analysis are often impractical due to minimum sample input requirements. Here the authors develop a microfluidic sample preparation platform that reduces sample input requirements 100-fold and enables high throughput sequencing from low numbers of cells.
Journal Article
High contiguity Arabidopsis thaliana genome assembly with a single nanopore flow cell
by
Loudet, Olivier
,
Monsanto Company
,
Weigel, Detlef
in
45/23
,
631/114/2785
,
631/181/457/649/2157
2018
The handheld Oxford Nanopore MinION sequencer generates ultra-long reads with minimal cost and time requirements, which makes sequencing genomes at the bench feasible. Here, we sequence the gold standard Arabidopsis thaliana genome (KBS-Mac-74 accession) on the bench with the MinION sequencer, and assemble the genome using typical consumer computing hardware (4 Cores, 16 Gb RAM) into chromosome arms (62 contigs with an N50 length of 12.3 Mb). We validate the contiguity and quality of the assembly with two independent single-molecule technologies, Bionano optical genome maps and Pacific Biosciences Sequel sequencing. The new A. thaliana KBS-Mac-74 genome enables resolution of a quantitative trait locus that had previously been recalcitrant to a Sanger-based BAC sequencing approach. In summary, we demonstrate that even when the purpose is to understand complex structural variation at a single region of the genome, complete genome assembly is becoming the simplest way to achieve this goal.
Journal Article