Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
4,571 result(s) for "Nucleic Acid Amplification Techniques"
Sort by:
Development and validation of four one-step real-time RT-LAMP assays for specific detection of each dengue virus serotype
4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia. 4 final reaction primer mixes were obtained by using a combination of Principal Component Analysis of the full DENV genome sequences, and LAMP primer design based on sequence alignments using the LAVA software. These mixes contained 14 (DENV1), 12 (DENV2), 8 (DENV3) and 3 (DENV4) LAMP primer sets. The assays were evaluated with an External Quality Assessment panel from Quality Control for Molecular Diagnostics. The assays were serotype-specific and did not cross-detect with other flaviviruses. The limits of detection, with 95% probability, were 22 (DENV1), 542 (DENV2), 197 (DENV3) and 641 (DENV4) RNA molecules, and 100% reproducibility in the assays was obtained with up to 102 (DENV1) and 103 RNA molecules (DENV2, DENV3 and DENV4). Validation of the DENV2 assay with blood samples from Tanzania resulted in 23 samples detected by RT-LAMP, demonstrating that the assay is 100% specific and 95.8% sensitive (positive predictive value of 100% and a negative predictive value of 85.7%). All serum samples from Senegal, Sudan and Mauritania were detected and 3 untyped as DENV1. The sensitivity of RT-LAMP for DENV4 samples from Cambodia did not quite match qRT-PCR. We have shown a novel approach to design LAMP primers that makes use of fast growing sequence databases. The DENV1 and DENV2 assays were validated with viral RNA extracted clinical samples, showing very good performance parameters.
Rapid lateral flow immunoassay for the fluorescence detection of SARS-CoV-2 RNA
The coronavirus disease 2019 (COVID-19) pandemic has highlighted the need for rapid and accurate nucleic acid detection at the point of care. Here, we report an amplification-free nucleic acid immunoassay, implemented on a lateral flow strip, for the fluorescence detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in less than one hour. The assay uses DNA probes that are designed to bind to the conserved open reading frame 1ab (ORF1ab), envelope protein (E) and the nucleocapsid (N) regions of the SARS-CoV-2 genome, and a fluorescent-nanoparticle-labelled monoclonal antibody that binds to double-stranded DNA–RNA hybrids. In a multi-hospital randomized double-blind trial involving 734 samples (593 throat swabs and 141 sputum) provided by 670 individuals, the assay achieved sensitivities of 100% and specificities of 99% for both types of sample (ground truth was determined using quantitative PCR with reverse transcription). The inexpensive amplification-free detection of SARS-CoV-2 RNA should facilitate the rapid diagnosis of COVID-19 at the point of care. A nucleic acid immunoassay implemented on a lateral flow strip accurately detects SARS-CoV-2 RNA in less than one hour via a fluorescence readout.
Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2
The previous outbreaks of SARS-CoV and MERS-CoV have led researchers to study the role of diagnostics in impediment of further spread and transmission. With the recent emergence of the novel SARS-CoV-2, the availability of rapid, sensitive, and reliable diagnostic methods is essential for disease control. Hence, we have developed a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the specific detection of SARS-CoV-2. The primer sets for RT-LAMP assay were designed to target the nucleocapsid gene of the viral RNA, and displayed a detection limit of 10 2 RNA copies close to that of qRT-PCR . Notably, the assay has exhibited a rapid detection span of 30 min combined with the colorimetric visualization. This test can detect specifically viral RNAs of the SARS-CoV-2 with no cross-reactivity to related coronaviruses, such as HCoV-229E, HCoV-NL63, HCoV-OC43, and MERS-CoV as well as human infectious influenza viruses (type B, H1N1pdm, H3N2, H5N1, H5N6, H5N8, and H7N9), and other respiratory disease-causing viruses (RSVA, RSVB, ADV, PIV, MPV, and HRV). Furthermore, the developed RT-LAMP assay has been evaluated using specimens collected from COVID-19 patients that exhibited high agreement to the qRT-PCR. Our RT-LAMP assay is simple to perform, less expensive, time-efficient, and can be used in clinical laboratories for preliminary detection of SARS-CoV-2 in suspected patients. In addition to the high sensitivity and specificity, this isothermal amplification conjugated with a single-tube colorimetric detection method may contribute to the public health responses and disease control, especially in the areas with limited laboratory capacities.
Low saliva pH can yield false positives results in simple RT-LAMP-based SARS-CoV-2 diagnostic tests
Diagnosis of any infectious disease is vital for opportune treatment and to prevent dissemination. RT-qPCR tests for detection of SARS-CoV-2, the causative agent for COVID-19, are ideal in a hospital environment. However, mass testing requires cheaper and simpler tests, especially in settings that lack sophisticated machinery. The most common current diagnostic method is based on nasopharyngeal sample collection, RNA extraction, and RT-qPCR for amplification and detection of viral nucleic acids. Here, we show that samples obtained from nasopharyngeal swabs in VTM and in saliva can be used with or without RNA purification in an isothermal loop-mediated amplification (LAMP)-based assay, with 60–93% sensitivity for SARS-CoV-2 detection as compared to standard RT-qPCR tests. A series of simple modifications to standard RT-LAMP published methods to stabilize pH fluctuations due to salivary acidity resulted in a significant improvement in reliability, opening new avenues for efficient, low-cost testing of COVID-19 infection.
MobileLAMP: A low-cost, portable incubation device for isothermal nucleic acid amplification
Isothermal amplification-based methods for pathogen DNA or RNA detection offer high sensitivity, rapid detection, and the potential for deployment in remote fields and home testing. Consequently, they are emerging as alternatives to PCR and saw a surge in research activity and deployment for the rapid detection of SARS-CoV-2 during the Covid-19 pandemic. The most common isothermal DNA detection methods rely on minimal reagents for DNA amplification and simple hardware that can maintain isothermal conditions and read-out a fluorescent or colorimetric signal. Many researchers globally are working on improving these components based on diverse end-user needs. In this work, we present MobileLAMP, an open-source, 3D-printed incubation device designed for loop-mediated isothermal amplification (LAMP). Composed of off-the-shelf components, MobileLAMP is easily manufacturable and can be powered via any 5V USB source. The device maintains high thermal stability (standard deviation = 0.2°C) across a functional range typically used for LAMP (55–65°C) while consuming only 365 mA of current. Efficacy was demonstrated through the colorimetric detection of SARS-CoV-2 and Salmonella enterica serovar Typhi within a 60-minute incubation period. With a total component cost of less than $5, MobileLAMP provides a highly accessible platform for decentralised molecular diagnostics, supporting both distributed manufacturing and field-based applications.
To culture or not to culture: correlating Neisseria gonorrhoeae culture positivity with nucleic acid amplification test cycle threshold values to promote cost-effective gonococcal resistance surveillance
ObjectivesEffective surveillance of antimicrobial-resistant Neisseria gonorrhoeae (Ng) is crucial, but culturing is labourious and costly. Focusing culturing efforts on high-yield subpopulations can enhance resource utilisation without compromising data quality or care. This cross-sectional retrospective study aims to pinpoint a nucleic acid amplification test (NAAT) cycle threshold (Ct) value for effective Ng surveillance culturing.MethodsSurveillance and laboratory data from 3042 sexual health clinic clients in the Netherlands (December 2018 to October 2023) were analysed to determine correlations between Ng culture positivity and NAAT Ct value, culture timing and anatomical location. Fisher’s exact χ² test assessed associations between culture recovery and time intervals between NAAT and culture collection. Receiver operator curves and Youden’s J statistic were applied to determine an optimal Ct value cut-off.NAAT was performed on 6346 swabs from urogenital (urethra; 1389/vagina; 482) and extragenital (oropharynx; 2306/rectum; 2169) sites using the cobas CT/NG assay on the 6800 platform (Roche Molecular Systems). Culture plates were inoculated on the initial test day for clients treated presumptively (symptoms or notified for Ng) or during treatment consultation after positive NAAT results.ResultsMean Ct values differed for positive and negative cultures (negative: Ct 33.0 (IQR 24.2–41.9); positive: Ct 25.4 (IQR 20.0–30.3); p<0.001). Oropharyngeal samples had the lowest culture positivity rate (22.0%). Culture positivity particularly declined when NAAT to culture intervals exceeded 14 days. Only 0.8% (11/1389) of urethral culture samples were positive above Ct 30. Between Ct 34 and 35, overall culture positivity dropped from 23.0% to 13.9%. A Ct value cut-off at 34 would reduce basic culturing costs by 25% while missing only 4.2% (108/2603) of positive cultures.ConclusionsEstablishing an NAAT Ct value cut-off can reduce both labour and costs without compromising vital surveillance data. Assay-specific validation is recommended prior to broader application.
Loop-mediated isothermal amplification (LAMP): Early detection of Toxoplasma gondii infection in mice
Background Toxoplasmosis is a widespread zoonotic parasitic disease that occurs in both animals and humans. Traditional molecular assays are often difficult to perform, especially for the early diagnosis of Toxoplasma gondii infections. Here, we established a novel loop-mediated isothermal amplification targeting the 529 bp repeat element ( 529 bp -LAMP) to detect T. gondii DNA in blood samples of experimental mice infected with tachyzoites of the RH strain. Findings The assay was performed with Bst DNA polymerase at 65°C for 1 h. The detection limit of the 529 bp- LAMP assay was as low as 0.6 fg of T. gondii DNA. The sensitivity of this assay was 100 and 1000 fold higher than that of the LAMP targeting B1 gene ( B1 -LAMP) and nested PCR targeting 529 bp repeat element ( 529 bp -nested PCR), respectively. The specificity of the 529 bp- LAMP assay was determined using the DNA samples of Trypanosoma evansi, Plasmodium falciparum, Paragonimus westermani, Schistosoma japonicum, Fasciola hepatica and Angiostrongylus cantonensis . No cross-reactivity with the DNA of any parasites was found. The assay was able to detect T. gondii DNA in all mouse blood samples at one day post infection (dpi). Conclusions We report the following findings: ( i ) The detection limit of the 529 bp- LAMP assay is 0.6 fg of T. gondii DNA; ( ii ) The assay does not involve any cross-reactivity with the DNA of other parasites; ( iii ) This is the first report on the application of the LAMP assay for early diagnosis of toxoplasmosis in blood samples from experimentally infected mice. Due to its simplicity, sensitivity and cost-effectiveness for common use, we suggest that this assay should be used as an early diagnostic tool for health control of toxoplasmosis.
Rapid (30-second), equipment-free purification of nucleic acids using easy-to-make dipsticks
The complexity of current nucleic acid isolation methods limits their use outside of the modern laboratory environment. Here, we describe a fast and affordable method to purify nucleic acids from animal, plant, viral and microbial samples using a cellulose-based dipstick. Nucleic acids can be purified by dipping in-house-made dipsticks into just three solutions: the extract (to bind the nucleic acids), a wash buffer (to remove impurities) and the amplification reaction (to elute the nucleic acids). The speed and simplicity of this method make it ideally suited for molecular applications, both within and outside the laboratory, including limited-resource settings such as remote field sites and teaching institutions. Detailed instructions for how to easily manufacture large numbers of dipsticks in house are provided. Using the instructions, readers can create more than 200 dipsticks in <30 min and perform dipstick-based nucleic acid purifications in 30 s. The authors describe how to easily prepare a large number of dipsticks from cellulose-based filter paper and use them to rapidly purify nucleic acids from a variety of sources.
Novel approaches toward preferential detection of viable cells using nucleic acid amplification techniques
This article elaborates on possible future directions for microbial viability assessment using nucleic acid-modifying compounds in combination with DNA- (and potentially RNA-) amplification technologies. Bacteria were traditionally considered viable when they could be cultured, whereas today's viability concept is based on the presence of some form of metabolic activity, responsiveness, RNA transcripts that tend to degrade rapidly after cell death, or of an intact membrane. The latter criterion was the focus of recent approaches to limit detection to intact cells using ethidium monoazide or propidium monoazide. Membrane integrity must, however, be considered as a very conservative criterion for microbial viability. The new concept presented here aims at limiting nucleic acid-based detection to cells with an active metabolism, which might be a more appropriate viability criterion. To selectively detect only cells with metabolic and respiratory activity (while excluding inactive dead cells from detection), we suggest the use of 'activity-labile compounds'. In addition to their potential usefulness for viability assessment, these new compounds could also be beneficial for selectively amplifying nucleic acids of cells that have metabolic activities of interest. This preferential detection of microorganisms with certain metabolic capabilities is referred to as 'molecular enrichment' in distinction to 'growth enrichment'.
Performances of rapid and connected salivary RT-LAMP diagnostic test for SARS-CoV-2 infection in ambulatory screening
Abstract In the context of social events reopening and economic relaunch, sanitary surveillance of SARS-CoV-2 infection is still required. Here, we evaluated the diagnostic performances of a rapid, extraction-free and connected reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay on saliva. Nasopharyngeal (NP) swabs and saliva from 443 outpatients were collected simultaneously and tested by reverse-transcription quantitative PCR (RT-qPCR) as reference standard test. Seventy-one individuals (16.0%) were positive by NP and/or salivary RT-qPCR. Sensitivity and specificity of salivary RT-LAMP were 85.9% (95%CI 77.8–94.0%) and 99.5% (98.7–100%), respectively. Performances were similar for symptomatic and asymptomatic participants. Moreover, SARS-CoV-2 genetic variants were analyzed and no dominant mutation in RT-LAMP primer region was observed during the period of the study. We demonstrated that this RT-LAMP test on self-collected saliva is reliable for SARS-CoV-2 detection. This simple connected test with optional automatic results transfer to health authorities is unique and opens the way to secure professional and social events in actual context of economics restart.