Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
10,877
result(s) for
"Time domain analysis"
Sort by:
Time-Domain Implementation and Analyses of Multi-Motion Modes of Floating Structures
2022
The study of wave-structure interactions involving nonlinear forces would often make use of the popular hybrid frequency–time domain method. In the hybrid method, the frequency-domain analysis could firstly provide the reliable and accurate dynamic parameters and responses; then these parameters and responses are transformed to the parameters to establishing the basic time-domain equation. Additionally, with the addition of the required linear and nonlinear forces, the time-domain analysis can be used to solve for the practical problems. However, the transformation from the frequency domain to the time domain is not straightforward, and the implementation of the time-domain equation could become increasingly complicated when different modes of motion are coupled. This research presents a systematic introduction on how to implement the time-domain analysis for floating structures, including the parameter transformations from the frequency domain to the time domain, and the methods for calculating and approximating the impulse functions and the fluid-memory effects, with special attention being paid to the coupling terms among the different motion modes, and the correctness of the time-domain-equation implementation. The main purpose of this article is to provide relevant information for those who wish to build their own time-domain analyses with the open-source hydrodynamic analysis packages, although commercial packages are available for time-domain analyses.
Journal Article
Survey on time‐domain power theories and their applications for renewable energy integration in smart‐grids
by
Godoy Simões, Marcelo
,
Harirchi, Farnaz
,
Babakmehr, Mohammad
in
B0220 Mathematical analysis
,
B8120K Distributed power generation
,
B8210 Energy resources
2019
The increasing aggregation of renewable‐based distributed generating units besides the impressive growing usage of non‐linear loads raises unwanted challenges for traditional power terms definition in power engineering. This fact consequently affected the performance of the conventional control frameworks and industrial compensation techniques. In this study, the authors aim to provide an insightful summary over the most recognised time domain‐based instantaneous power theories and discuss their advantages and disadvantages within a comprehensive mathematical‐conceptual and applicational framework for professionals who are using instantaneous power theories within the smart grid applications. They conclude that there is still a need for a modified power theory which can be validated under non‐sinusoidal‐unbalanced load/source conditions respecting the physical meaning of different power and current components.
Journal Article
Incipient fault location method for distribution networks with underground shielded cables: A system identification approach
by
Mora‐Flórez, Juan
,
Orozco‐Henao, Cesar Augusto
,
Herrera‐Orozco, Andrés Ricardo
in
Cables
,
Curve fitting
,
Design parameters
2017
Summary
Incipient faults in underground shielded cables can affect greatly distribution system reliability. These faults are usually a consequence of a gradual aging process on cable isolation material and over time become permanent faults. This paper presents an incipient fault location method for distribution networks with underground shielded cables. The fault location method is composed by a time domain system model and a parameter estimation approach. The model is derived by using phase component representation of voltage and current signals, considering 1‐terminal measurements and realistic hypotheses. Inherent characteristics of underground distribution networks with shielded cables and incipient faults, as unbalanced operation, complete line model, and arcing phenomena are considered during the problem statement. The time‐domain model is an overdetermined system of linear equations. Incipient fault location is estimated through a parameter estimation approach, based on a non‐negative weighted least square estimator. Input data are preprocessed with smooth and curve‐fitting approaches. Output data are postprocessing using a back substitution approach. Validation using real‐life distribution network with underground shielded cables data is presented. Comparative test results with the state of art characterize the proposed approach precision and robustness. High accuracy, easy to implement methodology without hard‐to‐design parameters, and only local terminal measurements consideration highlight potential aspects for real‐life applications.
Journal Article
A Quasi Time-Domain Method for Fatigue Analysis of Reactor Pressure Vessels in Floating Nuclear Power Plants in Marine Environments
2024
The reactor pressure vessel (RPV) in onshore nuclear power plants is typically analysed for fatigue life by considering the temperature, internal pressure, and seismic effects using a simplified time-domain fatigue analysis. In contrast, the frequency-domain fatigue analysis method is commonly employed to assess the fatigue life of ship structures. The RPV of a floating nuclear power plant (FNPP) is subjected to a combination of temperature, internal pressure, and wave loads in the marine environment. Consequently, it is essential to effectively integrate the frequency-domain fatigue analysis method used for hull structures with the time-domain fatigue analysis method for RPVs in FNPPs or, alternatively, to develop a suitable method that effectively accounts for the temperature, internal pressure, and wave loads. In this study, a quasi-time-domain method is proposed for the fatigue analysis of RPVs in FNPPs. In this method, secondary components of marine environmental loads are filtered out using principal component analysis. Subsequently, the stress spectrum induced by waves is transformed into a stress time history. Fatigue stress under the combined influence of temperature, internal pressure, and wave loads is then obtained through a stress component superposition method. Finally, the accuracy of the quasi-time-domain method was validated through three numerical examples. The results indicate that the calculated values obtained by the quasi-time-domain method are slightly higher than those obtained by the traditional time-domain method, with a maximum deviation of no more than 24%. Additionally, the computation time of the quasi-time-domain method is reduced by 98.67% compared to the traditional time-domain method.
Journal Article
Detection and Characterization of Multiple Discontinuities in Cables with Time-Domain Reflectometry and Convolutional Neural Networks
by
Ragolia, Mattia Alessandro
,
Spadavecchia, Maurizio
,
Scarpetta, Marco
in
Cables
,
convolutional neural network
,
distributed sensing
2021
In this paper, a convolutional neural network for the detection and characterization of impedance discontinuity points in cables is presented. The neural network analyzes time-domain reflectometry signals and produces a set of estimated discontinuity points, each of them characterized by a class describing the type of discontinuity, a position, and a value quantifying the entity of the impedance discontinuity. The neural network was trained using a great number of simulated signals, obtained with a transmission line simulator. The transmission line model used in simulations was calibrated using data obtained from stepped-frequency waveform reflectometry measurements, following a novel procedure presented in the paper. After the training process, the neural network model was tested on both simulated signals and measured signals, and its detection and accuracy performances were assessed. In experimental tests, where the discontinuity points were capacitive faults, the proposed method was able to correctly identify 100% of the discontinuity points, and to estimate their position and entity with a root-mean-squared error of 13 cm and 14 pF, respectively.
Journal Article
Topology optimization of bi-material structures with frequency-domain objectives using time-domain simulation and sensitivity analysis
by
Peng, Yingchao
,
Zhou, Pingzhang
,
Du, Jianbin
in
Computational Mathematics and Numerical Analysis
,
Engineering
,
Engineering Design
2021
In this paper, we propose to use time-domain transient analysis to compute the response of structures in a wide frequency band by means of Fourier transform. A time-domain adjoint variable method is then developed to carry out the sensitivity analysis of frequency-domain objective functions. By using the concept of frequency response function, it turns out that both the objective function and its sensitivity information at multiple frequencies can be obtained by one original simulation and at most one adjoint simulation, respectively. It is also demonstrated that some commonly used performance indices, e.g., dynamic compliance and input power, are indeed self-adjoint; thus, no extra adjoint simulations are needed, which makes the sensitivity analysis extremely efficient. An obvious distinction between the proposed method and the traditional frequency domain methods is that in our method, the frequency response curves in a wide band can be obtained
in each iteration
with no extra costs. It follows that it is easy to
track
the evolution of the frequency response curve in our method, which is essential in both computational and engineering sense. Several numerical examples are tested to show the effectiveness of the proposed method.
Journal Article
Frequency‐dependent finite‐difference time‐domain method based on iterated Crank–Nicolson scheme
by
Shibayama, Jun
,
Nakano, Hisamatsu
,
Yamauchi, Junji
in
Crank-Nicholson method
,
finite difference methods
,
Investigations
2023
The finite‐difference time‐domain (FDTD) method based on the iterated Crank–Nicolson (ICN) scheme is extended to a frequency‐dependent version. The Drude model is used to express a metal dispersion, which is incorporated into the iterated Crank–Nicolson formulation with the trapezoidal recursive convolution technique. The validity of the present finite‐difference time‐domain method with convolutional perfectly matched layers is discussed through the analysis of a metal‐insulator‐metal plasmonic waveguide. Numerical results obtained from a two‐iteration technique are found to agree well with those from the traditional explicit finite‐difference time‐domain method.
The transmission spectra are calculated using the proposed FDTD method based on the iterated Crank‐ Nicolson scheme. The result obtained from the proposed method is in perfect agreement with that obtained from the traditional explicit FDTD method.
Journal Article
Association between mental illness and blood pressure variability: a systematic review
2022
Background
Mental illness represents a major global burden of disease worldwide. It has been hypothesised that individuals with mental illness have greater blood pressure fluctuations that lead to increased cardiovascular risk and target organ damage. This systematic review aims to (i) investigate the association between mental illness and blood pressure variability (BPV) and (ii) describe methods of BPV measurements and analysis which may affect pattern and degree of variability.
Methods
Four electronic databases were searched from inception until 2020. The quality assessment was performed using STROBE criteria. Studies were included if they investigated BPV (including either frequency or time domain analysis) in individuals with mental illness (particularly anxiety/generalised anxiety disorder, depression/major depressive disorder, panic disorder and hostility) and without hypertension. Two authors independently screened titles, abstracts and full texts. A third author resolved any disagreements.
Results
Twelve studies met the inclusion criteria. Three studies measured short-term BPV, two measured long-term BPV and seven measured ultra-short-term BPV. All studies related to short-term BPV using ambulatory and home blood pressure monitoring found a higher BPV in individuals with depression or panic disorder. The two studies measuring long-term BPV were limited to the older population and found mixed results. Mental illness is significantly associated with an increased BPV in younger and middle-aged adults. All studies of ultra-short-term BPV using standard cardiac autonomic assessment; non-invasive continuous finger blood pressure and heart rate signals found significant association between BPV and mental illness. A mixed result related to degree of tilt during tilt assessment and between controlled and spontaneous breathing were observed in patients with psychological state.
Conclusions
Current review found that people with mental illness is significantly associated with an increased BPV regardless of age. Since mental illness can contribute to the deterioration of autonomic function (HRV, BPV), early therapeutic intervention in mental illness may prevent diseases associated with autonomic dysregulation and reduce the likelihood of negative cardiac outcomes. Therefore, these findings may have important implications for patients' future physical health and well-being, highlighting the need for comprehensive cardiovascular risk reduction.
Journal Article
Multi‐view synergistic enhanced fault recording data for transmission line fault classification
by
Han, Fengjun
,
Wang, Wei
,
Ma, Haifeng
in
signal classification
,
signal detection
,
smart power grids
2024
Fault recorded data has been proven to be effective for fault diagnosis of overhead transmission lines. Utilizing deep learning to mine potential fault patterns in fault recording data is an inevitable trend. However, it is usually difficult to obtain massive labeled fault recording data, which results in deep learning‐based fault diagnosis models not being adequately trained. Although data augmentation methods provide ideas for expanding the training data, existing data augmentation algorithms (e.g. random perturbation‐based augmentation) may lead to distortion of multi‐view data, that is, time domain data and frequency domain data of the fault recorded data, which results in the inconsistency of physical properties and statistical distributions of the generated data and the actual recording data, and misguides the training of the models. Hence, this study proposes a transmission line fault classification method via the multi‐view synergistic enhancement of fault recording data. The methodology proposes to start with a synergistic enhancement of multi‐view data such as time and frequency domains of fault recording data, and utilizes contrastive learning to further improve the performance of the fault classification model while ensuring that the generated data is not distorted. Experimental results on three real‐world datasets validate the effectiveness of the proposed method.
This study proposes a transmission line fault classification method via the multi‐view synergistic enhancement of fault recording data. The methodology proposes to start with a synergistic enhancement of multi‐view data such as time and frequency domains of fault recording data and utilizes contrastive learning to further improve the performance of the fault classification model while ensuring that the generated data is not distorted.
Journal Article
Experimental investigation on the correlation of pressure pulsation and vibration of axial flow pump
by
Duan, Xiaohui
,
Shi, Lijian
,
Zhou, Wei
in
Axial flow pumps
,
Correlation coefficients
,
Flow velocity
2019
Pressure and vibration displacement value are relatively measured by 14 pressure sensors and 2 vibration sensors distributing inside the tank-type model axial flow pump device under different flow rates. By comparison, it is found that the pressure pulsation on the inlet of the impeller is the main cause of hydraulic induced vibration of the pump device, and it is found to have similar amplitude trend with the vertical vibration as the flow rates increases and large correlation coefficient with the horizontal vibration under high flow rates through time-domain analysis. By frequency-domain analysis, it is found that the main frequency of pressure pulsation is three multiplies of the shaft frequency, but it is one multiplies of vertical vibration, and it changes from one multiplies to three multiplies of horizontal vibration. Combining with the analysis of phase-flow rates characteristics of both pressure pulsation and vibration, it is concluded that, for the horizontal vibration, the frequency ingredient of one multiplies ranging from low to high flow rates and three multiplies removing from unstable and high flow rates zone are possibly induced by pressure pulsation on the inlet of impeller, while for the vertical vibration, the frequency ingredient of one multiplies under design flow rates and high flow rates are possibly induced by pressure pulsation on the inlet of impeller. Both the horizontal and vertical vibrations with frequency of two multiplies have little relationship with the pressure pulsation on the inlet of impeller.
Journal Article