Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
175 result(s) for "Tissue Array Analysis - instrumentation"
Sort by:
Single-cell genome sequencing at ultra-high-throughput with microfluidic droplet barcoding
More than 50,000 single-cell genomes are sequenced in a single run using droplet barcoding. The application of single-cell genome sequencing to large cell populations has been hindered by technical challenges in isolating single cells during genome preparation. Here we present single-cell genomic sequencing (SiC-seq), which uses droplet microfluidics to isolate, fragment, and barcode the genomes of single cells, followed by Illumina sequencing of pooled DNA. We demonstrate ultra-high-throughput sequencing of >50,000 cells per run in a synthetic community of Gram-negative and Gram-positive bacteria and fungi. The sequenced genomes can be sorted in silico based on characteristic sequences. We use this approach to analyze the distributions of antibiotic-resistance genes, virulence factors, and phage sequences in microbial communities from an environmental sample. The ability to routinely sequence large populations of single cells will enable the de-convolution of genetic heterogeneity in diverse cell populations.
Multi-tissue interactions in an integrated three-tissue organ-on-a-chip platform
Many drugs have progressed through preclinical and clinical trials and have been available – for years in some cases – before being recalled by the FDA for unanticipated toxicity in humans. One reason for such poor translation from drug candidate to successful use is a lack of model systems that accurately recapitulate normal tissue function of human organs and their response to drug compounds. Moreover, tissues in the body do not exist in isolation, but reside in a highly integrated and dynamically interactive environment, in which actions in one tissue can affect other downstream tissues. Few engineered model systems, including the growing variety of organoid and organ-on-a-chip platforms, have so far reflected the interactive nature of the human body. To address this challenge, we have developed an assortment of bioengineered tissue organoids and tissue constructs that are integrated in a closed circulatory perfusion system, facilitating inter-organ responses. We describe a three-tissue organ-on-a-chip system, comprised of liver, heart, and lung, and highlight examples of inter-organ responses to drug administration. We observe drug responses that depend on inter-tissue interaction, illustrating the value of multiple tissue integration for in vitro study of both the efficacy of and side effects associated with candidate drugs.
Human iPSC-based Cardiac Microphysiological System For Drug Screening Applications
Drug discovery and development are hampered by high failure rates attributed to the reliance on non-human animal models employed during safety and efficacy testing. A fundamental problem in this inefficient process is that non-human animal models cannot adequately represent human biology. Thus, there is an urgent need for high-content in vitro systems that can better predict drug-induced toxicity. Systems that predict cardiotoxicity are of uppermost significance, as approximately one third of safety-based pharmaceutical withdrawals are due to cardiotoxicty. Here, we present a cardiac microphysiological system (MPS) with the attributes required for an ideal in vitro system to predict cardiotoxicity: i) cells with a human genetic background; ii) physiologically relevant tissue structure (e.g. aligned cells); iii) computationally predictable perfusion mimicking human vasculature; and, iv) multiple modes of analysis (e.g. biological, electrophysiological and physiological). Our MPS is able to keep human induced pluripotent stem cell derived cardiac tissue viable and functional over multiple weeks. Pharmacological studies using the cardiac MPS show half maximal inhibitory/effective concentration values (IC 50 /EC 50 ) that are more consistent with the data on tissue scale references compared to cellular scale studies. We anticipate the widespread adoption of MPSs for drug screening and disease modeling.
Flexible Micro Spring Array Device for High-Throughput Enrichment of Viable Circulating Tumor Cells
The dissemination of circulating tumor cells (CTCs) that cause metastases in distant organs accounts for the majority of cancer-related deaths. CTCs have been established as a cancer biomarker of known prognostic value. The enrichment of viable CTCs for ex vivo analysis could further improve cancer diagnosis and guide treatment selection. We designed a new flexible micro spring array (FMSA) device for the enrichment of viable CTCs independent of antigen expression. Unlike previous microfiltration devices, flexible structures at the micro scale minimize cell damage to preserve viability, while maximizing throughput to allow rapid enrichment directly from whole blood with no need for sample preprocessing. Device performance with respect to capture efficiency, enrichment against leukocytes, viability, and proliferability was characterized. CTCs and CTC microclusters were enriched from clinical samples obtained from breast, lung, and colorectal cancer patients. The FMSA device enriched tumor cells with 90% capture efficiency, higher than 10(4) enrichment, and better than 80% viability from 7.5-mL whole blood samples in <10 min on a 0.5-cm(2) device. The FMSA detected at least 1 CTC in 16 out of 21 clinical samples (approximately 76%) compared to 4 out of 18 (approximately 22%) detected with the commercial CellSearch® system. There was no incidence of clogging in over 100 tested fresh whole blood samples. The FMSA device provides a versatile platform capable of viable enrichment and analysis of CTCs from clinically relevant volumes of whole blood.
High-throughput cellular microarray platforms: applications in drug discovery, toxicology and stem cell research
Cellular microarrays are powerful experimental tools for high-throughput screening of large numbers of test samples. Miniaturization increases assay throughput while reducing reagent consumption and the number of cells required, making these systems attractive for a wide range of assays in drug discovery, toxicology, stem cell research and potentially therapy. Here, we provide an overview of the emerging technologies that can be used to generate cellular microarrays, and we highlight recent significant advances in the field. This emerging and multidisciplinary approach offers new opportunities for the design and control of stem cells in tissue engineering and cellular therapies and promises to expedite drug discovery in the biotechnology and pharmaceutical industries.
Porous microwells for geometry-selective, large-scale microparticle arrays
Large-scale microparticle arrays (LSMAs) are key for material science and bioengineering applications. However, previous approaches suffer from trade-offs between scalability, precision, specificity and versatility. Here, we present a porous microwell-based approach to create large-scale microparticle arrays with complex motifs. Microparticles are guided to and pushed into microwells by fluid flow through small open pores at the bottom of the porous well arrays. A scaling theory allows for the rational design of LSMAs to sort and array particles on the basis of their size, shape, or modulus. Sequential particle assembly allows for proximal and nested particle arrangements, as well as particle recollection and pattern transfer. We demonstrate the capabilities of the approach by means of three applications: high-throughput single-cell arrays; microenvironment fabrication for neutrophil chemotaxis; and complex, covert tags by the transfer of an upconversion nanocrystal-laden LSMA. A porous microwell platform that generates large-scale arrays of microparticles with varying shape, size and modulus with high specificity shows applicability in anti-counterfeiting and cell-screening applications.
Micro- and Nanoscale Technologies for Delivery into Adherent Cells
Several recent micro- and nanotechnologies have provided novel methods for biological studies of adherent cells because the small features of these new biotools provide unique capabilities for accessing cells without the need for suspension or lysis. These novel approaches have enabled gentle but effective delivery of molecules into specific adhered target cells, with unprecedented spatial resolution. We review here recent progress in the development of these technologies with an emphasis on in vitro delivery into adherent cells utilizing mechanical penetration or electroporation. We discuss the major advantages and limitations of these approaches and propose possible strategies for improvements. Finally, we discuss the impact of these technologies on biological research concerning cell-specific temporal studies, for example non-destructive sampling and analysis of intracellular molecules. Miniaturization of biotools: micro-/nanoscale biotools for cell transfection and analysis are being developed to achieve cell-specific experimental capabilities and localized cell–tool interfaces. This allows minimal perturbation to cells and unprecedented spatial resolution, which is essential for fundamental cell studies. Biotools for adherent cells: despite the risk for altering phenotype or stressing cells, conventional biotechnologies often require suspending and replating cells during in vitro studies. Novel micro/nanotechnologies are being developed to transfect and analyze adhered cells, which is particularly advantageous for longitudinal studies of individual cells or for investigating cell mechanisms. Combination of micro-/nanotechnologies with conventional biotechnologies: various strategies use micro-/nanotechnologies with conventional analytical tools such as fluorescence array readers and atomic force microscopes. This assembly approach promises revolutionary advances in biology and medicine.
A high-throughput platform for stem cell niche co-cultures and downstream gene expression analysis
Stem cells reside in ‘niches’, where support cells provide critical signalling for tissue renewal. Culture methods mimic niche conditions and support the growth of stem cells in vitro . However, current functional assays preclude statistically meaningful studies of clonal stem cells, stem cell–niche interactions, and genetic analysis of single cells and their organoid progeny. Here, we describe a ‘microraft array’ (MRA) that facilitates high-throughput clonogenic culture and computational identification of single intestinal stem cells (ISCs) and niche cells. We use MRAs to demonstrate that Paneth cells, a known ISC niche component, enhance organoid formation in a contact-dependent manner. MRAs facilitate retrieval of early enteroids for quantitative PCR to correlate functional properties, such as enteroid morphology, with differences in gene expression. MRAs have broad applicability to assaying stem cell–niche interactions and organoid development, and serve as a high-throughput culture platform to interrogate gene expression at early stages of stem cell fate choices. Magness and colleagues present a microwell-based culture system to analyse interactions between intestinal stem cells (ISCs) and Paneth cells, and show that their direct contact enhances formation of ISC-derived organoids.
A concentration gradient generator on a paper-based microfluidic chip coupled with cell culture microarray for high-throughput drug screening
Inspired by the paper platforms for 3-D cell culture, a paper-based microfluidic device containing drug concentration gradient was designed and constructed for investigating cell response to drugs based on high throughput analysis. This drug gradient generator was applied to generate concentration gradients of doxorubicin (DOX) as the model drug. HeLa cells encapsulated in collagen hydrogel were incubated in the device reservoirs to evaluate the cell viability based on the controlled release of DOX spatially. It was demonstrated that drug diffusion through the paper fibers created a gradient of drug concentration, which influenced cell viability. This drug screening platform has a great opportunity to be applied for drug discovery and diagnostic studies with simultaneous and parallel tests of drugs under various gradient concentrations.
Spheroid arrays for high-throughput single-cell analysis of spatial patterns and biomarker expression in 3D
We describe and share a device, methodology and image analysis algorithms, which allow up to 66 spheroids to be arranged into a gel-based array directly from a culture plate for downstream processing and analysis. Compared to processing individual samples, the technique uses 11-fold less reagents, saves time and enables automated imaging. To illustrate the power of the technology, we showcase applications of the methodology for investigating 3D spheroid morphology and marker expression and for in vitro safety and efficacy screens. First, spheroid arrays of 11 cell-lines were rapidly assessed for differences in spheroid morphology. Second, highly-positive (SOX-2), moderately-positive (Ki-67) and weakly-positive (βIII-tubulin) protein targets were detected and quantified. Third, the arrays enabled screening of ten media compositions for inducing differentiation in human neurospheres. Last, the application of spheroid microarrays for spheroid-based drug screens was demonstrated by quantifying the dose-dependent drop in proliferation and increase in differentiation in etoposide-treated neurospheres.