Catalogue Search | MBRL
Search Results Heading
Explore the vast range of titles available.
MBRLSearchResults
-
DisciplineDiscipline
-
Is Peer ReviewedIs Peer Reviewed
-
Item TypeItem Type
-
SubjectSubject
-
YearFrom:-To:
-
More FiltersMore FiltersSourceLanguage
Done
Filters
Reset
16
result(s) for
"electroactive response"
Sort by:
PVDF-based dielectric polymers and their applications in electronic materials
2018
The attractive dielectric poly(vinylidene fluoride) (PVDF) and its copolymers are well confirmed possessing the highest electroactive response including dielectric constant, piezoelectric and ferroelectric effects, which have increasingly wide range of applications such as in energy transfer, energy generation and storage, monitoring and control, and include the development of capacitors, sensors, actuators and so on. In this study, by clarifying the reliability of dielectric performances on their crystal phase structure of various PVDF polymers, the different physical and chemical fabricating ways to achieve different forms of PVDF samples such as linear polymers, ferroelectrics, and relaxor ferroelectrics were identified and quantified. In addition, many recent advances in the PVDF-based polymer dielectrics and some developed applications of these polymers are presented, which gives a reference in academic and engineering area to select an appropriate PVDF series dielectric polymer.
Journal Article
Interaction of Light with Different Electroactive Materials: A Review
At present, self-repairing, intelligent materials are being considered as future material. In this perspective, the electroactive materials are unique for their adaptability, sharp response time, control over the system, quick response rate, low power consumption, and compactness. The electroactive materials include electroactive polymers (EAPs), piezoelectric materials, electroactive gels, and fullerene compounds. The photonic interaction of light with the electroactive material converts light energy into mechanical energy and leads to multi-directional applications. Contemporarily with increased interest and emphasis on ‘green’ technological solutions, efforts are focussed on utilizing these electroactive materials with light energy. Corresponding to this, biomimetic and artificial intelligence are advancing to develop various optoelectronic devices, energy conversion and storage devices, photoresistors, vehicle components, sensors, robots, and medical devices. A better understanding of such light illumination with electroactive materials and prospective applications contributes to the planning of beneficial smart materials. Hence, this review article focusses on the interaction of light with different electroactive materials, their applications, and prospects of the current and future investigations.
Journal Article
Interspecies ecological competition rejuvenates decayed Geobacter electroactive biofilm
2024
Bioelectrochemical systems (BESs) exploit electroactive biofilms (EABs) for promising applications in biosensing, wastewater treatment, energy production, and chemical biosynthesis. However, during the operation of BESs, EABs inevitably decay. Seeking approaches to rejuvenate decayed EABs is critical for the sustainability and practical application of BESs. Prophage induction has been recognized as the primary reason for EAB decay. Herein, we report that introducing a competitive species of Geobacter uraniireducens suspended prophage induction in Geobacter sulfurreducens and thereby rejuvenated the decayed G. sulfurreducens EAB. The transcriptomic profile of G. sulfurreducens demonstrated that the addition of G. uraniireducens significantly affected the expression of metabolism- and stress response system-related genes and in particular suppressed the induction of phage-related genes. Mechanistic analyses revealed that interspecies ecological competition exerted by G. uraniireducens suppressed prophage induction. Our findings not only reveal a novel strategy to rejuvenate decayed EABs, which is significant for the sustainability of BESs, but also provide new knowledge for understanding phage–host interactions from an ecological perspective, with implications for developing therapies to defend against phage attack.
Graphical Abstract
Graphical Abstract
Journal Article
Graphene Functionalized Scaffolds Reduce the Inflammatory Response and Supports Endogenous Neuroblast Migration when Implanted in the Adult Brain
by
Coleman, Harold A.
,
Li, Dan
,
Zhou, Kun
in
Animals
,
Astrocytes - drug effects
,
Astrocytes - physiology
2016
Electroactive materials have been investigated as next-generation neuronal tissue engineering scaffolds to enhance neuronal regeneration and functional recovery after brain injury. Graphene, an emerging neuronal scaffold material with charge transfer properties, has shown promising results for neuronal cell survival and differentiation in vitro. In this in vivo work, electrospun microfiber scaffolds coated with self-assembled colloidal graphene, were implanted into the striatum or into the subventricular zone of adult rats. Microglia and astrocyte activation levels were suppressed with graphene functionalization. In addition, self-assembled graphene implants prevented glial scarring in the brain 7 weeks following implantation. Astrocyte guidance within the scaffold and redirection of neuroblasts from the subventricular zone along the implants was also demonstrated. These findings provide new functional evidence for the potential use of graphene scaffolds as a therapeutic platform to support central nervous system regeneration.
Journal Article
Soft Biomimetic Underwater Vehicles: A Review of Actuation Mechanisms, Structure Designs and Underwater Applications
2026
The growing demand for marine resource development and in-depth exploration of the marine environment has positioned soft biomimetic underwater vehicles (SBUVs) as a research hotspot in the fields of underwater equipment and soft robotics. SBUVs are characterized by bodies made of flexible and extensible materials, integrating the dual advantages of softness and biomimetics. They can achieve muscle-like continuous deformation to efficiently absorb collision energy, while mimicking the propulsion mechanisms of marine organisms—such as fish and jellyfish—through undulating body movements or cavity contraction and relaxation. Such biomimetic propulsion is highly compatible with the flexible actuation of soft materials, enabling excellent environmental adaptability while maintaining favorable propulsion efficiency. Compared with traditional rigid underwater vehicles, SBUVs offer higher degrees of freedom, superior environmental adaptability, enhanced impact resistance and greater motion flexibility. This review systematically summarizes typical actuation methods for SBUVs—including fluid-powered actuation, shape memory alloy actuation, and electroactive polymer actuation—elaborating on their working principles, key technological advances, and representative application cases on SBUVs. These actuation mechanisms each offer distinct advantages. Fluid-powered systems are valued for high power density and precise motion control through direct fluidic force transmission. Shape memory alloys provide high force output and accurate positional recovery via controlled thermal phase changes. Meanwhile, electroactive polymers stand out for their rapid (often millisecond-scale) dynamic response, low hysteresis, and fine, muscle-like deformation under electrical stimuli. Current challenges are also analyzed, such as limited actuation efficiency, material durability issues, and system integration difficulties. Despite these constraints, SBUVs show broad application prospects in marine resource exploration, ecological monitoring, and underwater engineering operations. Future research should prioritize the development of novel materials, coordinated optimization of actuation and control systems, and breakthroughs in core technologies to accelerate the practical implementation and industrialization of SBUVs.
Journal Article
Flexible Piezoresistive Sensors Based on PANI/rGO@PDA/PVDF Nanofiber for Wearable Biomonitoring
by
Xie, Guangzhong
,
Wang, Yuxiao
,
Chen, Chunxu
in
Biological monitoring
,
Biomonitoring
,
Carrier transport
2025
Fibrous structure is a promising building block for developing high-performance wearable piezoresistive sensors. However, the inherent non-conductivity of the fibrous polymer remains a bottleneck for highly sensitive and fast-responsive piezoresistive sensors. Herein, we reported a polyaniline/reduced graphene oxide @ polydopamine/poly (vinylidene fluoride) (PANI/rGO@PDA/PVDF) nanofiber piezoresistive sensor (PNPS) capable of versatile wearable biomonitoring. The PNPS was fabricated by integrating rGO sheets and PANI particles into a PDA-modified PVDF nanofiber network, where PDA was implemented to boost the interaction between the nanofiber networks and functional materials, PANI particles were deposited on a nanofiber substrate to construct electroactive nanofibers, and rGO sheets were utilized to interconnect nanofibers to strengthen in-plane charge carrier transport. Benefitting from the synergistic effect of multi-dimensional electroactive materials in piezoresistive membranes, the as-fabricated PNPS exhibits a high sensitivity of 13.43 kPa−1 and a fast response time of 9 ms, which are significantly superior to those without an rGO sheet. Additionally, a wide pressure detection range from 0 to 30 kPa and great mechanical reliability over 12,000 cycles were attained. Furthermore, the as-prepared PNPS demonstrated the capability to detect radial arterial pulses, subtle limb motions, and diverse respiratory patterns, highlighting its potential for wearable biomonitoring and healthcare assessment.
Journal Article
Polymeric Electrochemical Sensor for Calcium Based on DNA
by
Mohamed, Soha F.
,
Zareh, Mohsen M.
,
Elsheikh, Anas M.
in
Calcium ions
,
Chemical sensors
,
Dairy products
2022
Plastic membranes containing deoxyribonucleic acid (DNA) as an electroactive material were acting as Ca2+ selective sensors. Diethyl phthalate (DEP), dioctyl Phthalate (DOP), or nitrophenyl octyl ether (NPOE) were used as plasticizers and polyvinyl chloride (PVC) was the membrane matrix. A sensor with a membrane composition of 120 mg PVC, 60 mg DOP plasticizer, and 2 mg DNA ionophore (DNA: DOP: PVC, 1.0:29.2:0.1 mole) was found to have the best performance. The slope of the calibration graph was 30 mV decade−1. The optimum pH range was 5.7–9.5 for 0.01 M Ca2+. The sensor response time was fast (2–3 s) with a long working period (up to 3 weeks). Excellent selectivity for Ca2+ was indicated by the values of selectivity coefficients for different selected interference. The sensor was used effectively for the estimation of calcium in real samples (fruits, calcium syrup, milk, and dairy products).
Journal Article
A variational constitutive framework for the nonlinear viscoelastic response of a dielectric elastomer
2013
We formulate a variational constitutive framework that accounts for nonlinear viscous behavior of electrically sensitive polymers, specifically Dielectric Elastomers (DEs), under large deformation. DEs are highly viscoelastic and their actuation response is greatly affected in dynamic applications. We used the generalized Maxwell model to represent the viscoelastic response of DE allowing the material to relax with multiple mechanisms. The constitutive updates at each load increment are obtained by minimizing an objective function formulated using the free energy and electrostatic energy of the elastomer, in addition to the viscous dissipation potential of the dashpots in each Maxwell branch. The model is then used to predict the electromechanical instability (EMI) of DE. The electro-elastic response of the DE is verified with available analytical solutions in the literature and then the material parameters are calibrated using experimental data. The model is integrated with finite element software to perform a variety of simulations on different types of electrically driven actuators under various electromechanical loadings. The electromechanical response of the DE and the critical conditions at which EMI occurs were found to be greatly affected by the viscoelasticity. Our model predicts that under a dead load EMI can be avoided if the DE operates at a high voltage rate. Subjected to constant, ramp and cyclic voltage, our model qualitatively predicts responses similar to the ones obtained from the analytical solutions and experimental data available in the literature.
Journal Article
Actuation and dynamic mechanical characteristics of a core free flat dielectric electro-active polymer soft actuator
by
Wahab, Abdul Malek Abdul
,
A., Zainudin
,
Rustighi, Emiliano
in
Actuation
,
Actuators
,
dielectric electro-active polymer
2020
Various complex shapes of dielectric electro-active polymer (DEAP) actuator have been promoted for several types of applications. In this study, the actuation and mechanical dynamics characteristics of a new core free flat DEAP soft actuator were investigated. This actuator was developed by Danfoss PolyPower. DC voltage of up to 2000 V was supplied for identifying the actuation characteristics of the actuator and compare with the existing formula. The operational frequency of the actuator was determined by dynamic testing. Then, the soft actuator has been modelled as a uniform bar rigidly fixed at one end and attached to mass at another end. Results from the theoretical model were compared with the experimental results. It was found that the deformation of the current actuator was quadratic proportional to the voltage supplied. It was found that experimental results and theory were not in good agreement for low and high voltage with average percentage error are 104% and 20.7%, respectively. The resonance frequency of the actuator was near 14 Hz. Mass of load added, inhomogeneity and initial tension significantly affected the resonance frequency of the soft actuator. The experimental results were consistent with the theoretical model at zero load. However, due to inhomogeneity, the frequency response function’s plot underlines a poor prediction where the theoretical calculation was far from experimental results as values of load increasing with the average percentage error 15.7%. Hence, it shows the proposed analytical procedure not suitable to provide accurate natural frequency for the DEAP soft actuator.
Journal Article
A Novel Capacitance-Based In-Situ Pressure Sensor for Wearable Compression Garments
by
Sixt, Jeffrey
,
Salehian, Armaghan
,
Edher, Hamza
in
Bladder
,
capacitive pressure sensors
,
cardiac output
2019
This paper pertains to the development & evaluation of a dielectric electroactive polymer-based tactile pressure sensor and its circuitry. The evaluations conceived target the sensor’s use case as an in-situ measurement device assessing load conditions imposed by compression garments in either static form or dynamic pulsations. Several testing protocols are described to evaluate and characterize the sensor’s effectiveness for static and dynamic response such as repeatability, linearity, dynamic effectiveness, hysteresis effects of the sensor under static conditions, sensitivity to measurement surface curvature and temperature and humidity effects. Compared to pneumatic sensors in similar physiological applications, this sensor presents several significant advantages including better spatial resolution, compact packaging, manufacturability for smaller footprints and overall simplicity for use in array configurations. The sampling rates and sensitivity are also less prone to variability compared to pneumatic pressure sensors. The presented sensor has a high sampling rate of 285 Hz that can further assist with the physiological applications targeted for improved cardiac performance. An average error of ± 5.0 mmHg with a frequency of 1–2 Hz over a range of 0 to 120 mmHg was achieved when tested cyclically.
Journal Article