Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Language
      Language
      Clear All
      Language
  • Subject
      Subject
      Clear All
      Subject
  • Item Type
      Item Type
      Clear All
      Item Type
  • Discipline
      Discipline
      Clear All
      Discipline
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
25,546 result(s) for "minimally invasive surgery"
Sort by:
Development and validation of a recommended checklist for assessment of surgical videos quality: the LAParoscopic surgery Video Educational GuidelineS (LAP-VEGaS) video assessment tool
IntroductionThere has been a constant increase in the number of published surgical videos with preference for open-access sources, but the proportion of videos undergoing peer-review prior to publication has markedly decreased, raising questions over quality of the educational content presented. The aim of this study was the development and validation of a standard framework for the appraisal of surgical videos submitted for presentation and publication, the LAParoscopic surgery Video Educational GuidelineS (LAP-VEGaS) video assessment tool.MethodsAn international committee identified items for inclusion in the LAP-VEGaS video assessment tool and finalised the marking score utilising Delphi methodology. The tool was finally validated by anonymous evaluation of selected videos by a group of validators not involved in the tool development.Results9 items were included in the LAP-VEGaS video assessment tool, with every item scoring from 0 (item not presented in the video) to 2 (item extensively presented in the video), with a total marking score ranging from 0 to 18. The LAP-VEGaS video assessment tool resulted highly accurate in identifying and selecting videos for acceptance for conference presentation and publication, with high level of internal consistency and generalisability.ConclusionsWe propose that peer review in adherence to the LAP-VEGaS video assessment tool could enhance the overall quality of published video outputs.Graphic Abstract
Guide to Minimally Invasive Aesthetic Procedures
Amid today's growing demand for cosmetic medicine, Guide to Minimally Invasive Aesthetic Procedures provides a reliable, up-to-date, and highly illustrated guide to the wide variety of aesthetic procedures commonly requested and performed in this fast-changing field.
Unilateral biportal endoscopic lumbar interbody fusion versus minimally invasive transforaminal lumbar interbody fusion for single-segment lumbar degenerative disease: a meta-analysis
Background Minimally invasive spine surgery has seen rapid development in recent years. The purpose of this study was to evaluate the use of unilateral biportal endoscopic lumbar interbody fusion (ULIF) versus minimally invasive surgery transforaminal interbody fusion (MIS-TLIF) for the treatment of single-segment lumbar degenerative disease (LDD) through a systematic review and meta-analysis. Methods In collaboration with various search terms, a comprehensive examination of the scientific literature was carried out using PubMed, China National Knowledge Infrastructure (CNKI), Wanfang, and other databases. A total of 9 studies were included retrospective cohort studies. Results We observed statistically significant differences in intraoperative blood loss, total hospital stay, postoperative hospital stays, and 1-month postoperative Oswestry Disability Index (ODI) scores between the ULIF and MIS-TLIF groups, with the ULIF group being more dominant. MIS-TLIF group was statistically more advantageous in terms of operative time. There were no statistically significant differences in postoperative visual analogue scale (VAS) scores, 3-month postoperative and final ODI scores, excellent and good rate, complications, disc heights, and lumbar lordosis angle between the two groups. Conclusions Treatment of single-segment LDD with ULIF and MIS-TLIF is both safe and effective. ULIF has the advantage of less intraoperative blood loss, shorter total hospital stay, shorter postoperative hospital stay, and lower ODI scores at 1 month postoperatively compared to MIS-TLIF. There were no significant differences between ULIF and MIS-TLIF in the treatment of LDD in terms of postoperative VAS scores, 3-month postoperative and final ODI scores, satisfaction rates, fusion rates, complications, disc heights, and lumbar lordosis angle. MIS-TLIF has a shorter procedure time than ULIF.
Minimally Invasive Spine Stabilization for Pyogenic Spondylodiscitis: A 23-Case Series and Review of Literature
Background and Objectives: The incidence of pyogenic spondylodiscitis has been increasing due to the aging of the population. Although surgical treatment is performed for refractory pyogenic spondylodiscitis, surgical invasiveness should be considered. Recent minimally invasive spine stabilization (MISt) using percutaneous pedicle screw (PPS) can be a less invasive approach. The purpose of this study was to evaluate surgical results and clinical outcomes after MISt with PPS for pyogenic spondylodiscitis. Materials and Methods: Clinical data of patients who underwent MISt with PPS for pyogenic spondylitis were analyzed. Results: Twenty-three patients (18 male, 5 female, mean age 67.0 years) were retrospectively enrolled. The mean follow-up period was 15.9 months after surgery. The causative organism was identified in 16 cases (69.6%). A mean number of fixed vertebrae was 4.1, and the estimated blood loss was 145.0 mL. MISt with PPS was successfully performed in 19 of 23 patients (82.6%). Four cases (17.4%) required additional anterior debridement and autologous iliac bone graft placement. CRP levels had become negative at an average of 28.4 days after surgery. There was no major perioperative complication and no screw or rod breakages during follow-up. Conclusions: MISt with PPS would be a less invasive approach for pyogenic spondylodiscitis in elderly or immunocompromised patients.
A Full‐Range Proximity‐Tactile Sensor Based on Multimodal Perception Fusion for Minimally Invasive Surgical Robots
Minimally invasive surgical robots have received widespread attention due to its numerous advantages. However, the lack of adequate perception capability remains a significant issue for the robots. In this work, a full‐range proximity‐tactile sensing module has been developed for safe operation of surgical robots, which performs multimodal fusion perception through ultrasonic sensor for long‐range proximity detection, capacitive sensor for close‐range proximity sensing, and triboelectric sensor for tactile sensing. In order for a minimum sensor size, the ultrasonic sensor is developed based on MEMS piezoelectric micromachined ultrasonic transducers (pMUTs), and the capacitive sensor and triboelectric sensor adopt common structures, which collaborate to achieve accurate proximity‐tactile perception. Additionally, a wireless vibration feedback wristband and digital‐twin interface are developed to provide multimodal feedback without interfering with operation. Experimental results demonstrates the safety enhancement for surgical robots by the perception and feedback system. Furthermore, the sensing module is applied in preliminary detection of subcutaneous abnormal tissues and the identification accuracy based on the ultrasound echoes and convolutional neural networks is 91.6%, which can provide an initial diagnostic reference. The full‐range proximity‐tactile sensor holds significant potential for enhancing the safety and detection capability of surgical robots, and promoting the intelligence of robot‐assisted minimally invasive surgery. A full‐range proximity‐tactile sensing module is developed for safe operation of surgical robots, which performs multimodal fusion perception through ultrasonic sensor for long‐range proximity detection, capacitive sensor for close‐range proximity sensing, and triboelectric sensor for tactile sensing. Meantime, the sensing module can be applied in preliminary detection of subcutaneous abnormal tissues, providing an initial diagnostic reference.
Comparison of Outcomes between Minimally Invasive Lateral Approach Vertebral Reconstruction Using a Rectangular Footplate Cage and Conventional Procedure Using a Cylindrical Footplate Cage for Osteoporotic Vertebral Fracture
The aim of the current study was to compare outcomes between lateral access vertebral reconstruction (LAVR) using a rectangular footplate cage and the conventional procedure using a cylindrical footplate cage in patients with osteoporotic vertebral fracture (OVF). We included 46 patients who underwent anterior–posterior combined surgery for OVF: 24 patients underwent LAVR (Group L) and 22 underwent the conventional procedure (Group C). Preoperative, postoperative, and 1- and 2-year follow-up X-ray images were used to measure local lordotic angle, correction loss, and cage subsidence (>2 mm in vertebral endplate depression). In anterior surgery, the operation time was significantly shorter (183 vs. 248 min, p < 0.001) and the blood loss was significantly less (148 vs. 406 mL, p = 0.01) in Group L than in Group C. In Group C, two patients had anterior instrumentation failure. Correction loss was significantly smaller in Group L than in Group C (1.9° vs. 4.9° at 1 year, p = 0.02; 2.5° vs. 6.5° at 2 years, p = 0.04, respectively). Cage subsidence was significantly less in Group L than in Group C (29% vs. 80%, p < 0.001). LAVR using a rectangular footplate cage is an effective treatment for OVF to minimize surgical invasiveness and postoperative correction loss.
Evaluation of Triggered Electromyogram Monitoring during Insertion of Percutaneous Pedicle Screws
Objective: percutaneous pedicle screw (PPS) fixation has been widely used in minimally invasive spine stabilization. Triggered electromyogram (TrEMG) monitoring is performed to prevent PPS misplacement, but is not widely accepted. We have newly developed an insulating tap device to minimize the misplacement of PPS. Methods: TrEMG was measurable in insulation tap devices in 31 cases, and in non-insulating tap devices in 27 cases. Fluoroscopy was used to insert 194 PPS and 154 PPS, respectively. Based on the Rampersaud classification of postoperative computed tomography, we classified PPS insertion into four categories (Grade A as no violation, Grade D as more than 4 mm perforation). Results: Grade A was noted in 168 PPSs (86.6%) and Grade B to D in 26 PPSs in the insulation tap device group, and Grade A was noted in 129 PPSs (83.8%) and Grade B to D in 25 PPSs in the non-insulating tap device group, respectively. At a cutoff value of 11 mA, the sensitivity was 41.4% and the specificity was 98.2%. The sensitivity and specificity of the non-insulating tap device were 4.0% and 99.2%, respectively. Conclusions: The insulation treatment of the tap device has improved the sensitivity of TrEMG. TrEMG using the insulating tap device is one of the methods for safe PPS insertion.
Comparison of Surgical Outcomes between Single-Port Laparoscopic Surgery and Da Vinci Single-Port Robotic Surgery
Background: The aim of this study is to compare the surgical outcomes of single-port laparoscopic surgery (SPLS) and single-port robotic surgery (SPRS). Methods: We retrospectively analyzed patients who underwent a hysterectomy, ovarian cystectomy, or myomectomy with SPLS or SPRS from January 2020 to July 2022. Statistical analyses were performed using the SPSS chi-square test and student’s t-test. Results: A total of 566 surgeries including single-port laparoscopic hysterectomy (SPLH; n = 148), single-port robotic hysterectomy (SPRH; n = 35), single-port laparoscopic ovarian cystectomy (SPLC; n = 207), single-port robotic ovarian cystectomy (SPRC; n = 108), single-port laparoscopic myomectomy (SPLM; n = 12), and single-port robotic myomectomy (SPRM; n = 56). The SPRH, SPRC, and SPRM groups had a shorter operation time than the SPLS group, although the results were not statistically significant (SPRH vs. SPLH, p = 0.134; SPRC vs. SPLC, p = 0.098; SPRM vs. SPLM, p = 0.202). Incisional hernia occurred as a postoperative complication in two patients only in the SPLH group. Postoperative Hb changes were lower in the SPRC and SPRM groups than in the SPLC and SPLM groups (SPRC vs. SPLC, p = 0.023; SPRM vs. SPLM, p = 0.010). Conclusions: Our study demonstrated that the SPRS had comparable surgical outcomes when compared to the SPLS. Therefore, the SPRS should be considered a feasible and safe option for gynecologic patients.
Conditions for Achieving Postoperative Pelvic Incidence-Lumbar Lordosis < 10° in Circumferential Minimally Invasive Surgery for Adult Spinal Deformity
This retrospective study aimed to evaluate the clinical outcomes of circumferential minimally invasive surgery (CMIS) using lateral lumbar interbody fusion (LLIF) and percutaneous pedicle screw (PPS) in adult spinal deformity (ASD) patients, and to clarify the conditions for achieving postoperative pelvic incidence-lumbar lordosis (PI-LL) < 10°. Demographics and other parameters of ASD patients who underwent CMIS and who were divided into groups G (achieved postoperative PI-LL < 10°) and P (PI-LL ≥ 10°) were compared. Of the 145 included ASD patients who underwent CMIS, the average fused level, bleeding volume, operative time, and number of intervertebral discs that underwent LLIF were 10.3 ± 0.5 segments, 723 ± 375 mL, 366 ± 70 min, and 4.0 segments, respectively. The rod material was titanium alloy in all the cases. The PI-LL significantly improved from 37.3 ± 17.9° to 1.2 ± 12.2° postoperatively. Pre- and postoperative PI, postoperative LL, preoperative PI-LL, PI-LL after LLIF, and postoperative PI-LL were significantly larger in group P. PI-LL after LLIF was identified as a significant risk factor of postoperative PI-LL < 10° by logistic regression, and the cut-off value on receiver operating characteristic curve analysis was 20°. Sufficient correction was achieved by CMIS. If PI-LL after LLIF was ≤20°, it was corrected to the ideal alignment by the PPS procedure.