Search Results Heading

MBRLSearchResults

mbrl.module.common.modules.added.book.to.shelf
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
    Done
    Filters
    Reset
  • Discipline
      Discipline
      Clear All
      Discipline
  • Is Peer Reviewed
      Is Peer Reviewed
      Clear All
      Is Peer Reviewed
  • Item Type
      Item Type
      Clear All
      Item Type
  • Subject
      Subject
      Clear All
      Subject
  • Year
      Year
      Clear All
      From:
      -
      To:
  • More Filters
      More Filters
      Clear All
      More Filters
      Source
    • Language
416 result(s) for "prosthesis: reverse"
Sort by:
Mid- to long-term outcome of reverse total shoulder arthroplasty as revision procedure for failed hemiarthroplasty after proximal humerus fracture
Background Insufficient tuberosity healing is the most common reason for poor outcome after treatment of proximal humerus fractures (PHFs) using hemiarthroplasty (HA). In these cases, revision to reverse total shoulder arthroplasty (RTSA) can improve function and reduce pain in the short term, however, long-term results remain scarce. Aim of this study was to evaluate the clinical and radiological mid- to long-term results in patients with a revision RTSA after failed HA for PHF. Methods In this retrospective study all patients that received a revision to RTSA after failed fracture HA between 2006 and 2018 were included. A total of 49 shoulders in 48 patients (38 female, 10 male; mean age 82 ± 9 years) were identified in our database. A total of 20 patients (17 female, 3 male; mean age was 79 ± 9 years) were available for follow-up examination after a mean time period of approximately eight years (3–14 years) after revision surgery. At final follow-up, patients were assessed using a subjective shoulder value (SSV), range of motion (ROM), visual analogue score (VAS), the Constant Score (CS) and the 12-Item Short Form Survey (SF-12). Results At final follow-up, mean CS was 55 ± 19 (19–91), VAS averaged 3 ± 3 (0–8) and mean SSV was 61 ± 18% (18–90%). Mean SF-12 was 44 (28–57) with a mean physical component summary (PCS) of 38 (21–56) and a mean mental component summary (MCS) of 51 (29–67). On average active forward flexion (FF) was 104° (10–170°), active abduction (ABD) was 101° (50–170°), active external rotation (ER) was 19° (10–30°) and active internal rotation (IR) of the lumbosacral transition was reached. Three patients presented with a periprosthetic humeral fracture after RTSA implantation and underwent a reoperation (15%) during follow-up period. Conclusions Revision RTSA results in promising clinical results in patients after initial failed HA after PHF. A complication and reoperation rate of 15% is tolerable in consideration of satisfactory functional and psychological outcome. Trial registration Retrospectively registered.
Humeral and Glenoid Version in Reverse Total Shoulder Arthroplasty: A Systematic Review
There is increasing interest in reverse total shoulder arthroplasty (RTSA) as a reliable treatment for arthritic, rotator cuff deficient shoulders. Humeral and glenoid version are controversial parameters that can influence internal and external rotation, muscular forces, and implant stability as outcomes of RTSA. The aim of this study was to obtain an overview of the current knowledge on the effect of both humeral component version and glenoid component version and give recommendations on their most optimal degree for RTSA. A comprehensive quantitative review of the published literature on the effect of humeral version and glenoid version in RTSA was performed, to identify its influence on the range of movement, muscle forces, and intrinsic stability of the reverse prosthesis. Eleven studies were included: nine were biomechanical studies, one was a clinical-radiographic study, and one was an implant design consideration. Anterior stability can be improved by implanting the humeral component in neutral or with some anteversion. Glenoid component retroversion has been proven to reduce the likelihood of subluxation, while increasing ER and ROM at the same time. The study was conducted considering 5° anteversion; neutral; and 5°, 10°, and 20° retroversion of the glenoid component. Although a final opinion has not been yet expressed on the matter, the general consensus tends to agree on restoring 0° to 20° of retroversion of the humeral and glenoid component to yield the best outcomes.
Shoulder Surgery Postoperative Immobilization: An International Survey of Shoulder Surgeons
Background: There is currently no consensus on immobilization protocols following shoulder surgery. The aim of this study was to establish patterns and types of sling use for various surgical procedures in the United States (US) and Europe, and to identify factors associated with the variations. Methods: An online survey was sent to all members of the American Shoulder and Elbow Society (ASES) and European Society for Surgery of the Shoulder and Elbow (ESSSE). The survey gathered member data, including practice location and years in practice. It also obtained preferences for the type and duration of sling use after the following surgical procedures: arthroscopic Bankart repair, Latarjet, arthroscopic superior/posterosuperior rotator cuff repair (ARCR) of tears <3 cm and >3 cm, anatomic total shoulder arthroplasty (aTSA) and reverse TSA (rTSA), and isolated biceps tenodesis (BT). Relationships between physician location and sling type for each procedure were analyzed using Fisher’s exact tests and post-hoc tests using Bonferroni-adjusted p-values. Relationships looking at years in practice and sling duration preferred were analyzed using Spearman’s correlation tests. Results: In total, 499 surgeons with a median of 15 years of experience (IQR = 9–25) responded, with 54.7% from the US and 45.3% from Europe. US respondents reported higher abduction pillow sling use than European respondents for the following: Bankart repair (62% vs. 15%, p < 0.0001), Latarjet (53% vs. 12%, p < 0.001), ARCR < 3 cm (80% vs. 42%, p < 0.001) and >3 cm (84% vs. 61%, p < 0.001), aTSA (50% vs. 21%, p < 0.001) and rTSA with subscapularis repair (61% vs. 22%, p < 0.001) and without subscapularis repair (57% vs. 17%, p < 0.001), and isolated BT (18% vs. 7%, p = 0.006). European respondents reported higher simple sling use than US respondents for the following: Bankart repair (74% vs. 31%, p < 0.001), Latarjet (78% vs. 44%, p < 0.001), ARCR < 3 cm (50% vs. 17%, p < 0.001) and >3 cm (34% vs. 13%, p < 0.001), and aTSA (69% vs. 41%, p < 0.001) and rTSA with subscapularis repair (70% vs. 35%, p < 0.001) and without subscapularis repair (73% vs. 39%, p < 0.001). Increasing years of experience demonstrated a negative correlation with the duration of sling use after Bankart repair (r = −0.20, p < 0.001), Latarjet (r = −0.25, p < 0.001), ARCR < 3 cm (r = −0.14, p = 0.014) and >3 cm (r = −0.20, p < 0.002), and aTSA (r = −0.37, p < 0.001), and rTSA with subscapularis repair (r = −0.10, p = 0.049) and without subscapularis repair (r = −0.19, p = 0.022. Thus, the more experienced surgeons tended to recommend shorter durations of post-operative sling use. US surgeons reported longer post-operative sling durations for Bankart repair (4.8 vs. 4.1 weeks, p < 0.001), Latarjet (4.6 vs. 3.6 weeks, p < 0.001), ARCR < 3 cm (5.2 vs. 4.5 weeks p < 0.001) and >3 cm (5.9 vs. 5.1 weeks, p < 0.001), aTSA (4.9 vs. 4.3 weeks, p < 0.001), rTSR without subscapularis repair (4.0 vs. 3.6 weeks, p = 0.031), and isolated BT (3.7 vs. 3.3 weeks, p = 0.012) than Europe respondents. No significant differences between regions within the US and Europe were demonstrated. Conclusions: There is considerable variation in the immobilization advocated by surgeons, with geographic location and years of clinical experience influencing patterns of sling use. Future work is required to establish the most clinically beneficial protocols for immobilization following shoulder surgery. Level of Evidence: Level IV.
Lipoma of the Teres Minor in Rotator Cuff Arthropathy—A Case Report
Although lipomas are the most common mesenchymal tumors, the intramuscular type is rare. We report the case of a patient with rotator cuff arthropathy with a lipoma in the teres minor. Wide surgical excision and total shoulder arthroplasty with reverse prosthesis was performed and 18 months of follow up showed excellent results with any recurrence. The teres minor is extremely important for the proper function of a reverse prosthesis, and lipoma growth in the muscular belly can compromise the functionality of the prosthesis. To the best of our knowledge, this is the first case report of a rotator cuff arthropathy with a lipoma in the teres minor.
Trends in Shoulder Arthroplasty: A Narrative Review of Predominant Indications and the Most Commonly Employed Implant Designs
Background: Over the past few decades, shoulder arthroplasty has evolved rapidly, driven by a growing demand for surgical solutions to degenerative, traumatic, and irreparable rotator cuff-related pathologies, particularly in an aging but increasingly active population. Objective: This narrative review aims to examine the main clinical indications and the most commonly used implant designs, highlighting differences in functional outcomes, complication rates, and revision rates between anatomic total shoulder arthroplasty (ATSA) and reverse total shoulder arthroplasty (RTSA). Methods: Articles published between 2011 and 2025 were selected through PubMed and the Australian Joint Replacement Registry reports from 2023 and 2024. The included studies comprised randomized controlled trials, systematic reviews, and meta-analyses involving adult patients treated for primary osteoarthritis, proximal humerus fractures, and massive irreparable rotator cuff tears. Results: ATSA remains the preferred option in younger patients with an intact rotator cuff, due to superior outcomes in mobility and prosthesis longevity. However, glenoid component loosening remains a significant limitation. Initially reserved for irreparable cuff tears and complex fractures, RTSA has seen a progressive expansion of its indications, offering lower revision rates and satisfactory functional results, particularly in elderly patients. Recent prosthetic innovations include stemless implants, augmented glenoid components, and convertible platforms. Conclusions: The choice between ATSA and RTSA should be individualized, based on patient-specific factors such as age, rotator cuff integrity, functional demands, and bone quality. Advances in implant materials and design, together with improved patient selection, have significantly enhanced clinical outcomes.
Conversion of Hemiarthroplasty to Reverse Shoulder Arthroplasty with Humeral Stem Retention
The purpose of this study is to evaluate the mid-term clinical results of an ongoing case series on conversion reverse shoulder arthroplasty (RSA) with a modular prosthesis system. We included 17 elderly patients revised for failed hemiarthroplasty after proximal humeral fracture, of which 13 were converted using a modular reverse shoulder prosthesis. Four could not be converted due to overstuffing. For the conversion RSA, we determined the Constant score, American Shoulder and Elbow Surgeons Shoulder Score, visual analogue scale for pain and satisfaction, and range of motion preoperatively, at one year, and at the last follow-up. All measured clinical outcomes improved significantly at both follow-up time points (p < 0.05). The mean duration of surgery was 118.4 min (range: 80.0 to 140.0 min). We observed complications in three patients; these included one late infection and two aseptic stem loosenings. Modular shoulder arthroplasty is a suitable procedure for conversion RSA in elderly patients. All measured postoperative clinical outcomes improved significantly, the complication rate was acceptable, and no prosthesis-related complications occurred. Conversion RSA, although not feasible in every case, is a viable treatment option in the elderly, which can provide successful mid-term results.
Cementless and locked prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: prospective clinical evaluation of hemi- and reverse arthroplasty
IntroductionCemented stem remains the gold standard for prosthesis in trauma. The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem (hemi and reverse) for 3- and 4-part proximal humeral fractures.Materials and methodsOne hundred and thirty-four 3- and 4-part fractures have been treated by locked stem, 69 with hemiarthroplasty [mean age 68 years (50–90)] and 65 with reversed [mean age 78 years (66–91)]. The length of the stem was 15 cm with a proximal coating of HA automatic locking system (two screws) and four different diameters. Preliminary cadaver study allowed us to validate the system (22 shoulders, no injuries of nerves, locking system efficient).ResultsIn the group of hemi, Constant score with ponderation reached 72 (11–120) and QDash 31.2 (4.5–77.27) with a mean FU of 25 months (6–96). In the group of reversed, Constant score with ponderation reached 77.6 (28.8–119) and QDash 36.2 (2–84) with a mean FU of 15 months (6–41). Specific complications due to locking system reached 3% but without reoperation. Other complications were capsulitis and infection.DiscussionIn this population of elderly patient, new fall with periprosthetic fracture or infection led the surgeon to remove the stem. At shoulder level, the removal of a cemented stem remains a highly demanding procedure with sometimes bad functional results and elevated level of complications. This series is the first one of locked stem without significant complications. Locked stem remains a new but logical tool in trauma.
Two-Stage Exchange Arthroplasty for Periprosthetic Reverse Shoulder Arthroplasty Infection Provides Comparable Functional Outcomes to Primary Reverse Shoulder Arthroplasty
This study aimed to compare functional outcomes after two-stage revision reverse shoulder arthroplasty (RSA) for periprosthetic joint infection (PJI) with the results of primary RSA. Patients affected by PJI and treated by means of two-stage revision RSA were 1:1 matched with a group of patients who were treated electively with RSA without developing any complications. Out of 1477 RSAs performed between 2009 and 2021, 16 patients developed a PJI. Each matched cohort comprised 16 patients (3 females, 13 males). The mean age was 69.13 ± 5.43 years old in the PJI group and 70.28 ± 5.04 (p = 0.543) in the matched cohort. The mean follow-up was 41.23 ± 26.9 months in the PJI group and 28.5 ± 20.2 (p = 0.142) in the matched group. Only one patient showed recurrent PJI five years after revision RSA. Comparison between the PJI patients and matched patients did not show any significant differences at the latest follow-up, nor for subjective shoulder value (SSV) (p = 0.101) or Constant score (p = 0.134). Two-stage exchange RSA for PJI allows for appropriate control of the disease and good functional outcomes. Comparison with an age- and sex-matched cohort of uninfected patients showed no significant differences, thus confirming the idea that revision surgeries may lead to satisfactory functional outcomes, as expected after primary surgery.
Effect of two types of shoulder prosthesis on the muscle forces using a generic multibody model for different arm motions
Background This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality. Methods A three-dimensional musculoskeletal OpenSim® model of an upper body, incorporating a natural gleno-humeral joint and a scapula-thoracic joint developed by Blana et al. (J Biomech 41: 1714-1721, 2008), was used as a reference for the natural shoulder. It was modified by integrating first a novel dual-bearing prosthesis, and second, a reverse shoulder prosthesis into the shoulder joint complex. Four different arm motions, namely abduction, scaption, internal and external rotation, were simulated using an inverse kinematics approach. For each of the three models, shoulder muscle forces and joint reaction forces were calculated with a 2 kg weight in the hand. Results In general, the maximal shoulder muscle force and joint reaction force values were in a similar range for both prosthesis models during all four motions. The maximal deltoid muscle forces in the model with the dual-bearing prosthesis were 18% lower for abduction and 3% higher for scaption compared to the natural shoulder. The maximal rotator cuff muscle forces in the model with the dual-bearing prosthesis were 36% lower for abduction and 1% higher for scaption compared to the natural shoulder. Although the maximal deltoid muscle forces in the model with the dual-bearing prosthesis in internal and external rotation were 52% and 64% higher, respectively, compared to the natural shoulder, the maximal rotator cuff muscle forces were 27% lower in both motions. Conclusion The study shows that the dual-bearing shoulder prosthesis is a feasible option for patients with rotator cuff tear and has a strong potential to be used as secondary as well as primary joint replacement. The study also demonstrates that computer simulations can help to guide the continued optimization of this particular design concept for successful clinical outcomes.
Treatment of proximal humeral fractures with reverse shoulder arthroplasty in elderly patients
Background Proximal humeral fractures in four or even only three parts, with metaphyseal hinge distances of <8 mm, represent a serious and widely debated problem. Reduction is complex and plating is often instable, especially in elderly patients. Failures, sometimes involving necrosis of the head, are frequent. Hemiarthroplasty has long been used for 3- or 4-part complex fractures, even in young patients, although often with sub-optimal results, due to reabsorption of tuberosities. This complication has partly been overcome with reverse shoulder prostheses which, although more invasive than partial ones, may lead to less disappointing results, even in cases of reabsorption of tuberosities. We have data on a homogeneous series of patients treated with reverse shoulder arthroplasty for proximal fractures, with a maximum follow-up of 10 years. The aim of this study was mainly to identify which cases can be selected for effective treatment and which technical aspects are best to adopt. Materials and methods There were 33 patients in this study, mean age 76.6 years (range 54–85). Fractures were classified according to Neer. Surgery was undertaken on average 4.4 days after trauma. The deltopectoral approach was used. Sutures were hooked over the major and lesser tubercles for later reduction and fixation after the prosthesis had been applied. This passage was sometimes not possible in cases of serious degeneration of the rotator cuff. One day after surgery, a shoulder brace providing an abducted angle of 15° was applied for 30 days. Patients were re-assessed with DASH and Constant scores (CS), and the ratio between healthy and operated shoulders was calculated. Physical examination was followed by X-rays, mainly to evaluate and classify any infraglenoid scapular notching according to Nerot. Results Mean follow-up was 42.3 months (range 10–121). According to the CS, mean pain was 12.6/15 (range 3–15/15), activities of daily living 16.3/20 (range 8–20/20), ROM 21.8 (range 8–32/40) and power 5.4/25 (range 2–12/25). Total mean CS was 56.4 (range 23–80/100). The mean DASH score was 49.7 (range 32–90). The ratio of the CS parameters between opposite and operated shoulders was on average 72.8 % (range 28–90 %). Long-term complications were eight cases of scapular notching (24.2 %) of which four of grade 2 (12.1 %) and four of grade 1 (12.1 %). Conclusions Total reverse prostheses are more invasive because they also compromise the glenoid surface of the scapula, but they do offer good stability, even in cases of damage to the rotator cuff. Reverse prostheses have great advantages as regards to ROM, allowing functional recovery, which is good in cases with re-insertion of tuberosities, and acceptable in cases when tuberosities are not re-inserted or resorbed. In our cases, the first 3 reverse prostheses lasted 10, 8.3 and 7.3 years, and we believe that they will become increasingly long-lived, so that applying them in cases of complex fractures becomes more feasible. We prefer the deltopectoral approach because it can reduce and stabilize possible intra-operative diaphyseal fractures. Possible scapular notching must be foreseen when inserting the glenosphere. We had eight cases (24.2 %), of which four were Nerot grade 1 and four were grade 2. Applying the Kirschner wire in an infero-anterior position allows the glenosphere to be lowered with a tilt of 10°. Reverse prostheses are suitable for 3- or 4-part complex proximal humeral fractures in patients over 65. Prolonged physiokinesitherapy is essential.