Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
E-210 In vitro evaluation of flow diverter performance using a fibrinogen based flow model
by
Ericson, D
, Senol, Y
, Bilgin, C
, Kadirvel, R
, Arul, S
, Cebral, J
, Oliver, A
, Kallmes, D
in
Aneurysms
/ Chloride
/ SNIS 20th annual meeting electronic poster abstracts
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
E-210 In vitro evaluation of flow diverter performance using a fibrinogen based flow model
by
Ericson, D
, Senol, Y
, Bilgin, C
, Kadirvel, R
, Arul, S
, Cebral, J
, Oliver, A
, Kallmes, D
in
Aneurysms
/ Chloride
/ SNIS 20th annual meeting electronic poster abstracts
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
E-210 In vitro evaluation of flow diverter performance using a fibrinogen based flow model
Journal Article
E-210 In vitro evaluation of flow diverter performance using a fibrinogen based flow model
2023
Request Book From Autostore
and Choose the Collection Method
Overview
Background and PurposeThe safety and efficacy profile of flow diverter treatment for intracranial aneurysms has been well-established. However, predictors of successful flow diversion remain poorly characterized. Failed flow diversion attempts burden the healthcare system and put patients at risk due to long-term antiplatelet treatment and potential periprocedural complications. Fibrinogen deposition represents an integral component of intraaneurysmal thrombus formation. Therefore, we aimed to develop a preclinical testing platform utilizing fibrinogen to predict the in vivo performance of flow diverters.MethodsA flow diverter (4.75 x 20 mm) was deployed in the glass model of a saccular paraophthalmic segment aneurysm (4x4x4 mm). A human fibrinogen solution (Fibryga, Octopharma, Paramus, NJ) was circulated through the glass model using a peristaltic pump in triplicates. Thrombin, heparin, and calcium chloride were added to the fibrinogen solution, and physiologic blood concentrations were mimicked for all ingredients except heparin. The test fluid temperature was stabilized at 37°C with a heating bath. Complete aneurysm neck coverage time was recorded for varying flow rates (3, 4, and 5 cc/sec) with or without heparin or calcium chloride addition.ResultsFibrinogen specifically aggregated at the flow diverter’s aneurysm neck portion (100%, 6/6), while other segments of the flow diverter remained patent. Fibrinogen aggregation occurred without platelet aggregation or activation of other coagulation factors. The time to complete neck coverage varied between 15 (figure 1) and 24 minutes for different flow rates, with a higher flow rate achieving faster neck coverage. The model was sensitive to thrombin, heparin, and calcium chloride concentrations (table 1). With physiological concentrations and flow rate, the flow diverter’s portion at the aneurysm neck was completely covered in 20 minutes.ConclusionsOur preliminary study supports the potential of fibrinogen-based benchtop flow model as an effective tool for predicting flow diverter’s in vivo performance. In our study, fibrinogen-based flow model successfully reflected the changes in flow rates and concentrations of main procoagulants. Further research is needed to validate the utility of fibrinogen-based models in predicting flow diverter’s performance in patients.Abstract E-210 Figure 1Abstract E-210 Table 1Fibrinogen aggregation times for different flow rates and test solutions Experiment Fibrinogen Flow Rate Thrombin Heparin Calcium Chloride Coverage time 1 330mg/dl 3cc/sec 0.1 U/ml - - 24 min 2 330mg/dl 4cc/sec 0.1 U/ml - - 20 min 3 330mg/dl 5cc/sec 0.1 U/ml - - 15 min 4 330mg/dl 4cc/sec - - - 80 min 5 330mg/dl 4cc/sec 0.1 U/ml 1 U/ml - 33 min 6 330mg/dl 4cc/sec 0.1 U/ml 1 U/ml 8 mg/dl 21 min Disclosures C. Bilgin: None. A. Oliver: None. S. Arul: None. Y. Senol: None. D. Ericson: None. J. Cebral: None. D. Kallmes: None. R. Kadirvel: None.
Publisher
BMJ Publishing Group Ltd,BMJ Publishing Group LTD
MBRLCatalogueRelatedBooks
This website uses cookies to ensure you get the best experience on our website.