MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever
Journal Article

Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever

2017
Request Book From Autostore and Choose the Collection Method
Overview
BackgroundThe mechanism by which a stent retriever removes intraluminal thrombus from an occluded vessel in humans has not previously been studied. This study performed contrast-enhanced high-resolution cone beam CT (CE-HRCBCT) during deployment of the stent retriever to observe the interaction between the strut and intraluminal thrombus intraoperatively. We also discuss the mechanism by which the thrombus is retrieved.MethodsIn 11 patients, mechanical thrombectomy was performed with a Solitaire stent retriever. The presence or absence of flow restoration (FR) was evaluated immediately and at least 5 min after deployment. Stent retriever findings on CE-HRCBCT were divided into two groups: (1) complete expansion; and (2) incomplete expansion.ResultsFR was observed in all 11 cases (100%) immediately after deployment of the Solitaire stent retriever. Complete expansion was observed in only one case and incomplete expansion was observed in 10 cases. The thrombus was observed mainly near to or outside the strut of the stent retriever by CE-HRCBCT. Loss of FR was seen in only one of the 11 cases. Regardless of this, successful recanalization was achieved with only the stent retriever in nine cases.ConclusionsCE-HRCBCT showed that the Solitaire stent retriever rarely expanded fully and the thrombus was mainly near to or outside the strut. It may not be necessary to wait a long time to allow the stent to expand fully into the thrombus because the main capture mechanism seems to be engagement of the clot between the crossings of the struts of the Solitaire.