MbrlCatalogueTitleDetail

Do you wish to reserve the book?
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial
Journal Article

23-gauge versus 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial

2008
Request Book From Autostore and Choose the Collection Method
Overview
Aim:To compare the sutureless 23-gauge system with a standard 20-gauge system in pars plana vitrectomy.Methods:60 patients in two randomised groups were included in this prospective clinical trial. Pars plana vitrectomy with either 23- or 20-gauge instruments was performed. The main outcome measures were postoperative conjunctival injection and pain. Secondary outcome parameters were time of surgery, intraocular pressure, visual acuity and complications.Results:Conjunctival injection (p = 0.0003) and postoperative pain (p = 0.01) were significantly reduced following 23-gauge vitrectomy compared with the 20-gauge procedure. Opening (p = 0.006) and closure times (p<0.00001) were significantly shorter, and vitrectomy time (p = 0.001) significantly longer in the 23-gauge system compared with 20-gauge vitrectomy. However, retinal manipulation and overall surgery times did not differ significantly between both groups. The same applies for eye pressure, distance and reading acuity. Regarding complications, two choroidal haemorrhages and one flat serous choroidal detachment occurred in the 23-gauge group.Conclusion:The 23-gauge system for pars plana vitrectomy offers significantly higher patient comfort during the early postoperative period. Time of surgery is almost equal—a shorter time for wound closure is neutralised by a longer vitrectomy time in the 23-gauge group.