Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Explosion risk assessment for mining belt conveyors
by
Radu, Mirela Ancuța
, Râșnoveanu, Sorin
, Popa, Cătălin Mihai
in
Belt conveyors
/ Explosions
/ Firedamp
/ Mining
/ Modernization
/ Risk assessment
/ Safety devices
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Explosion risk assessment for mining belt conveyors
by
Radu, Mirela Ancuța
, Râșnoveanu, Sorin
, Popa, Cătălin Mihai
in
Belt conveyors
/ Explosions
/ Firedamp
/ Mining
/ Modernization
/ Risk assessment
/ Safety devices
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Explosion risk assessment for mining belt conveyors
2025
Request Book From Autostore
and Choose the Collection Method
Overview
As science and technology have developed, new types of equipment and installations with increased reliability and safety have emerged, with belt conveyors now available with many more components, highly sophisticated electrical controls and safety devices, as well as stronger and more durable belts. New technologies create new challenges in assessing explosion risks when installed in environments with potentially explosive atmospheres, such as in firedamp mines. The challenges are greater in the case of old installations that are being modernized to meet current explosion safety requirements. The paper presents a series of aspects regarding the assessment of the risk of explosions in mining belt conveyors, an assessment that employers must make, according to GD 1049/2006 (European Directive 92/104/EEC). The assessment must be based on compliance with the requirements of the ATEX Directive 2014/34/EU and the applicable standards. For surface installations, there is the draft standard IEC TS 60079-46 used for risk assessment but which does not apply to mine equipment assemblies susceptible to firedamp (group I applications). For mining installations there is no specific evaluation method or guide, therefore evaluators must generate their own evaluation method based on the norms and standards in force such as SR EN 1127-2: 2014, SR EN 60079-0:2018+AC, SR EN ISO 80079-36:2016, SR EN ISO 80079-37:2016, SR EN ISO/IEC 80079-38: 2017 (SR EN 1710+A1:2008 /AC:2011).
Publisher
EDP Sciences
Subject
This website uses cookies to ensure you get the best experience on our website.