MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Lightning Impulse Voltage Stresses In Underground Cables
Lightning Impulse Voltage Stresses In Underground Cables
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lightning Impulse Voltage Stresses In Underground Cables
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lightning Impulse Voltage Stresses In Underground Cables
Lightning Impulse Voltage Stresses In Underground Cables

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lightning Impulse Voltage Stresses In Underground Cables
Lightning Impulse Voltage Stresses In Underground Cables
Journal Article

Lightning Impulse Voltage Stresses In Underground Cables

2023
Request Book From Autostore and Choose the Collection Method
Overview
Underground power cables are crucial for transmission and distribution. Lightning can stress their insulation, but not directly. So, impulse cable testing is studied. This research examines the cable’s transient response to standard and non-standard lightning impulse voltage waveforms. MATLAB Simulink was used to model a 132 kV wire with standard and non-standard impulse voltages. The IEC60060-1(2010) lightning impulse test uses a conventional waveform impulse voltage with a front time and a tail time of 1.2/50μs half value, while the non-standard test uses a front time and a tail time of 0.8/12s half value. Non-standard impulse waveforms are more accurate than standard waveforms. The impulse test voltage is four to five times the underground cable’s operational voltage and must withstand five applications without damage. Standard and non-standard impulse waveforms are injected with 132 kV and 550 kV to evaluate insulation failure or damage. Standard lightning and non-standard impulse voltage waveforms do not cause insulation failure or damage. When 132 kV and 550 kV are introduced into the normal and non-standard lightning impulse waveforms, the overshoot voltage increases. The peak voltage of a non-standard 550 kV impulse voltage waveform exceeds the IEC impulse withstand voltage. The finding shows that non-standard impulse voltage waves create increased cable voltage stress.